NBS Source
Jag är en tillverkare

ITP FlameOUT® Block Standard Flame-retardant Class B VCL Vapour Barrier (B-s1,d0) - Air and Vapour Control Layer

Verifierad av tillverkaren för 1 dag sedan

iTP Produktcertifieringar:
  • CE Marking

    Certifikattyp

Flame-retardant Class B (B-s1,d0) air and vapour control layer (AVCL) for use in walls and roofs. Tested to EN 13501-1, suited to high-rise 18 m+ in England & 11 m+ in Scotland.

Hoppa till:
+44 (0)1347 825200 Webbplats

Applikation

ITP FlameOUT® Block Standard Class B is suitable for use in both walls and roofs.

Storage and handling:

  • Handle the membrane with care.
  • Ensure that the membrane is not punctured or damaged.
  • Store the membrane horizontally away from sunlight in a cool, dry sheltered store.

Installation:

  • ITP FlameOUT® Block Standard Class B should be continuous over the whole plan area of the structure. All laps should be sealed with ITP FlameOUT® D/S Jointing Tape. The number of joints should be kept to a minimum by using the full width of the membrane.
  • The VCL should be laid loose, flat and without wrinkles, ensuring that the membrane is not creased or folded.
  • Cold makes the VCL become less supple. Install in temperatures over 5℃. Do not install in windy conditions.
  • Joins should only be made where the membrane is supported.
  • A continuous single row of ITP FlameOUT® D/S Jointing Tape is recommended to seal the overlaps. All joins should be firmly pressed together using a hand-held pressure roller. Tapes should not be installed in temperatures below 5℃.
  • Prior to covering the VCL should be thoroughly inspected to verify the integrity of the joining and sealing and to ensure that no damage has occurred during installation.
  • Damaged areas must be repaired using patches of ITP FlameOUT® Block Standard Class B. The patch must not extend beyond 150 mm of the damaged area. Fix with ITP FlameOUT® D/S Jointing Tape.
  • Where services and pipework penetrate the AVCL, use ITP FlameOUT® D/S Jointing Tape to create airtight seals around each point of entry. To avoid cutting the membrane, it is important that the membrane is folded into the corner and then reinforced by an additional protective layer of membrane.
  • Protect ITP FlameOUT® Block Standard from UV exposure. Cover and finish the construction of the VCL installation within a maximum of 3 months.

Overlaps:

  • Horizontal overlaps should be 150 mm minimum.
  • Vertical overlaps should be 150 mm minimum.

See installation instructions for full details.

Beskrivning

ITP FlameOUT® Block Standard Class B is a polyethylene-based vapour control layer (AVCL) with a mono-filament reinforcement scrim to provide excellent tensile strength in wall and roof insulations. ITP FlameOUT® Block Standard Class B is independently tested to British and international flame retardant standards including EN 13501-1.

When used within wall and roof installations ITP FlameOUT® Block Standard Class B prevents moisture within the building's warm air from reaching the insulation layer and forming interstitial condensation.

ITP FlameOUT® Block Standard Class B contributes to both BS 9250 for the airtightness in ‘a well-sealed ceiling’ and BS 5250 aiding the control of condensation within a roof space.

Can be used in conjunction with ITP FlameOUT® Breathe Class B Euroclass B-s1,d0 breather membrane which is installed on the cold side of the building envelope.

Features and benefits:

  • Euroclass B-s1,d0 Class B flame-retardant AVCL.
  • Independently tested to EN 13501-1.
  • Compliant for use in high-rise and high risk buildings.
  • Compliant to Approved Document B.
  • Suitable for roof and wall applications.
  • Excellent tensile strength and nail tear resistance.
  • Reinforcement scrim.
  • Available in two grades: ITP FlameOUT® Block Premium and ITP FlameOUT® Block Standard.
  • Suitable for use as a damp proof membrane.
  • CE approval.

Accessories:

ITP FlameOUT D/S jointing tape:

Double-sided tape to seal flame-retardant breather membranes and VCLs.

  • Size: 60 mm x 25 m.
  • Colour: clear.
  • Flame retardancy: FMVSS 302 pass.
  • Temp range: -20°C to +70°C.
  • Installation range: +10°C to +35°C.

Allmän information

Färg

White

ytbehandling

Textured

Material

Polyethylene

Form

Rectangle

Längd

50000 mm

Bredd

2000 mm

Uniclass

Pr_25_57_65_60 PlastarkPrimär

CAWS

H31/45 Air and vapour control membrane

H31/261 Air and vapour control membrane

H30/30 Air and vapour control membrane

H30/261 Air and vapour control membrane

J31/330 Air and vapour control layer

J21/395 Air and vapour control layer

J41/395 Air and vapour control layer

J42/395 Air and vapour control layer

P10/60 Air and vapour control layer

P10/310 Air and vapour control layer

H92/780 Air and vapour control layer

Specifikationsdata - Plastskivor

Klassificeringsdata

Material

Polyethylene.

Purpose

Vapour control layer.

Standard

To EN 13984.

Performance characteristics

-

Tensile strength (minimum)

To EN 12311-1, >500 N/50 mm.

Tear resistance

To EN 12310-1, 220 N (MD); 179 N (CD).

Tillverkarens vägledning

Nominal.

Elongation to break

To EN 12311-1, 16%.

Tillverkarens vägledning

Nominal.

Fire performance

To EN ISO 13501-1, B-s1,d0.

Form

Reinforced.

Vägledning för specifikationsalternativ:

Mono-filament reinforcement scrim.

Physical properties

-

Colour

White.

Tillverkarens vägledning

Milky white.

Weight (minimum)

140 g/m².

Dimensions

-

Width (minimum)

2 m.

Roll length (minimum)

50 m.

Roll weight

14.5 kg.

Water vapour transmission

To EN ISO 12572 (C), 28 m.

Tillverkarens vägledning

Nominal.

Accessories

Not required.
ITP FlameOUT D/S jointing tape.

Vägledning för specifikationsalternativ:

Double-sided tape to seal flame-retardant breather membranes and VCLs.

  • Size: 60 mm x 25 m.
  • Colour: clear.
  • Flame retardancy: FMVSS 302 pass.
  • Temp range: -20°C to +70°C.
  • Installation range: +10°C to +35°C.

Hållbarhetsdata

Materialets ursprungsland

Europe

Produktens tillverkningsland

Europe

Material

Polyethylene

Återvinningsbarhet

Suitable for waste to energy

Produktcertifieringar

CE Marking

CE Marking

FlameOUT ® Block Standard - CE Marking

Dokumentation

FlameOUT® Block Standard Inst R3-6

FlameOUT® Block Standard Inst R3-6

FlameOUT® Block Standard DoP R4-5

FlameOUT® Block Standard DoP R4-5

Powerlon® Product Catalogue

Powerlon® Product Catalogue

Powerlon® Building Membranes SDS R5-2

Powerlon® Building Membranes SDS R5-2

FlameOUT Block Class B TDS R6-1

FlameOUT Block Class B TDS R6-1

Nyheter

Napier and New Plymouth House

Napier and New Plymouth House

Station House, Milton Keynes

Station House, Milton Keynes

The Registry, Beckenham, London

The Registry, Beckenham, London

The Silk District, Whitechapel, London

The Silk District, Whitechapel, London

Royal Eden Docks, London

Royal Eden Docks, London

Fairfax Homes Perrymount Apartments

Fairfax Homes Perrymount Apartments

Liknande produkter från iTP

ITP FlameOUT® Block Premium Flame-retardant Class B VCL Vapour Control Layer (B-s1,d0)  - Air and Vapour Control Layer

ITP FlameOUT® Block Premium Flame-retardant Class B VCL Vapour Control Layer (B-s1,d0) - Air and Vapour Control Layer

ITP Powerbase® Low Perm Gas Barrier - Protection Against Radon & Low Levels of Carbon Dioxide CO₂ - Gas Barrier Membranes

ITP Powerbase® Low Perm Gas Barrier - Protection Against Radon & Low Levels of Carbon Dioxide CO₂ - Gas Barrier Membranes

ITP Powerbase® Multigas Barriers - Protection Against Carbon Dioxide CO₂, Methane & Radon  - Gas Barrier Membranes

ITP Powerbase® Multigas Barriers - Protection Against Carbon Dioxide CO₂, Methane & Radon - Gas Barrier Membranes

ITP Powerbase® VOC - Volatile Organic Compound & Hydrocarbon Gas Barrier Membrane  - Vapour and Gas Barrier Membrane

ITP Powerbase® VOC - Volatile Organic Compound & Hydrocarbon Gas Barrier Membrane - Vapour and Gas Barrier Membrane

ITP Powerlon® VCL 250 & ITP Powerlon® VCL 170 - Vapour Control Layer (AVCL)  - Vapour Control Layer

ITP Powerlon® VCL 250 & ITP Powerlon® VCL 170 - Vapour Control Layer (AVCL) - Vapour Control Layer

ITP UltraBlock 200 & ITP UltraBlock 300 -Thermo Reflective Vapour Control Layer (AVCL)  - Thermo-Reflective Vapour Control Layer

ITP UltraBlock 200 & ITP UltraBlock 300 -Thermo Reflective Vapour Control Layer (AVCL) - Thermo-Reflective Vapour Control Layer