Verifierad av tillverkaren för 24 dagar sedan
118001-010 - TRIMEC ES8001-TBAS
A high torque motorized bolt.
Suitable for use with misaligned doors, timber doors, glass doors and aluminium doors.
The new ES8100, also known as the V-lock, contains a high torque motorised bolt which moves into a V shaped Strike Plate, pulling the door into alignment, when locked.
The ES8100 incorporates many improvements over its predecessor, the ES8000, including a higher preload rating of 100kg, Door Position Monitoring, integrated LED lock status and diagnostics visual indication, increased door misalignment correction from 7mm to 12mm, an IP53 rating for external door applications and simple, one-step, PTO/PTL onsite configuration.
The ES8100 can be mounted either vertically or horizontally but cannot be mounted in the floor. The ES8100 V-lock can be mortice mounted and concealed from view or surface mounted, with the inclusion of an optional kit.
Features and benefits:
Färg | Silver |
ytbehandling | Stainless steel |
Material | Stainless steel |
Form | Rectangle |
Längd | 41 mm |
Bredd | 30 mm |
Höjd | 256 mm |
Garantibeskrivning | Two year |
Uniclass | |
CAWS | P21/26 Special function door locks P21/530 Special function door locks |
SKU Code | ES8100 |
Product range |
Klassificeringsdata | |
Description | A high torque motorized bolt. |
Lock type | V-lock. Motorised bolt lock. |
Category of use | |
Duty | Medium-duty. |
Material and finish | Stainless steel lock body and faceplate. |
Standards | To EN 14846. |
Glass door kit | Not required. 218000-000. |
Voltage | 12–24 V d.c. Vägledning för specifikationsalternativ: 12V (+15% - 0%) 24V(+/- 15%). |
Current | Minimum 1 A regulated supply. |
Monitoring | COM, NO, NC. Vägledning för specifikationsalternativ: NO terminal, NC terminal and COM terminal. Voltage free changeover contacts rated at 48 dc/100mA. Tillverkarens vägledningDoor status monitor. |
Security | To AS4145.2- 1993, Passed S3. |
Strength | 1000 kg. Vägledning för specifikationsalternativ: Maximum; with supported strike plate. |
Mekanisk hållbarhet | 300 000 operations. |
OperationalTemperatureRange | -20°C to + 60°C. |
BoltSize | 11 mm diameter. |
Bolt projection | 20.5 mm. |
Accessories | Not required. ES8000-IK-FD30, TRIMEC ES8000 V-LOCK INTUMESCENT KIT TO SUIT FD30. ES8000-IK-FD60, TRIMEC ES8000 V-LOCK INTUMESCENT KIT TO SUIT FD60. |
Innehåller Red List-material | No |
Produktens tillverkningsland | Australia |
Material | Stainless steel |