ÖVERSIKT

To fulfil the requirements of BS8102:2022 and BS 8485:2015+A1:2019 a strategy to develop a specification which combines structural waterproofing and ground gas protection were required for this refurbishment project.

The project involved creating additional living space to an existing mid terrace Victorian property in W12. The site of the property, whilst not being located on contaminated land was identified as being potentially at risk, it was near what is classed as contaminated land (an old brick yard).


To satisfy Building Control requirements gas protection measures were required to meet BS 8485:2015+A1:2019.

Site investigations at former brickworks and landfill sites are within expected UK guidelines for contamination. Ground investigations incorporate both soil sampling, ground gas and groundwater monitoring.


In accordance with Table 3 of BS 8485:2015+A1:2019 a residential building is classed as a Type A building, creating a “high risk” requirement for ground gas protection. With the structure requiring a Grade 3 habitable environment attention as required to offer a system which meets all requirements.