NBS Source
I'm a manufacturer

Unity DF A1 (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Verified by manufacturer 6 months ago

Metalline Architectural Fabrications Third party certifications:
  • CWCT Certificate

    CWCT Certificate

    Certificate type

A versatile non-combustible rainscreen cassette system with a durable high-performance finish. Discrete fixings provide a streamlined appearance in both landscape and portrait orientation.

Jump to:
+44 (0)1543 456 930 Website

Application

Suitable for use on a range of construction projects.

Description

A versatile non-combustible rainscreen cassette system with a durable high-performance finish. Discrete fixings provide a streamlined appearance in both landscape and portrait orientation.


Features and benefits:

  • Manufactured from non-combustible material that has an A1 classification to EN 13501-1.
  • Developed and manufactured in accordance with CWCT guidelines.
  • Discrete fixings provide a streamlined appearance in both landscape and portrait orientation.
  • Available in anodized or pre-coat finishes in an extensive range of colours.
  • Offers protection to a building’s external facade.
  • Can be used to enhance the look and feel of both new build and refurbishment projects.
  • Can be installed horizontally and vertically.
  • Unity rainscreen panels with associated carriers, bracketry and support systems are designed to allow the correct flow of ventilation and drainage run off in line with current building regulations.
  • Panels available in lengths up to 6000 mm.
  • Design assistance available; consult manufacturer for details.

Part of a range of Unity A1 systems (specified separately) that includes:


  • A floor-to-floor framing system (F2F).
  • A through-fix rainscreen system (TF).
  • An interlocking rainscreen system (IL).
  • A secret-fix rainscreen system (SF).
  • An interlocking plank and soffit system (PS).

Installation:


  • The Unity A1 non-combustible rainscreen panel is produced using a solid aluminium substrate that can be fitted as either a cassette or as a flat-faced panel fixed onto an appropriately designed support framework.
  • Rainscreen cladding panel to be fixed to an appropriately designed carrier system.
  • Carrier rail profile to be fixed to a helping hand or primary support bracket through thermal insulation.
  • Helping hand support bracket to be fixed to SFS steel wall and cement board with stainless steel fixings (including thermal isolator).
  • Unity A1 F2F (floor-to-floor framing): Primary support bracket to be fixed back to main structure at every floor level using fixings/anchors which have been designed to withstand the imposed loading.


Consult manufacturer's technical literature for further details.

General information

Color

-

Manufacturer guidance

Extensive range of colours. Consult manufacturer and insert requirements

Finish

Anodized

Coated

Guidance for specification option:

Pre-coat.

Material

Aluminium

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

System performance

Developed and manufactured in accordance with CWCT guidelines.

Thermal insulation

-

Manufacturer guidance

Insert requirements.

Breather membrane

-

Material

-

Manufacturer guidance

Insert requirements.

Secondary support structure

CLAD-LINE CL1 Sub-Frame System.

Guidance for specification option:

Aluminium support system comprising extruded vertical support rails (T/L profiled rails) with adjustable wall attachment brackets to suit cladding zone.


CLAD-LINE’s T and L profiled rails are fixed using the CL range of support brackets which provide up to 30 mm adjustment of the rail face. Fixed Point (dead load) brackets are designed to absorb vertical dead loads while the Sliding Point brackets allow for expansion and contraction and are designed to absorb wind loads.

CLAD-LINE F2F (Floor to Floor) Sub-Frame System.

Guidance for specification option:

Floor to floor spanning support system comprising an extruded vertical sheeting rail (Rail Type 1–2 mm face, Rail Type 2–4 mm face), a Primary Angle Bracket, a BS Link Bracket (allowing for up to 30 degree rotation), Link Bracket Fixing Assemblies, a Fixed Point Clip and a Sliding Point Clip (if required).

Manufacturer guidance

To EN 755, extruded aluminium, 6063/T6 grade alloy.

Cavity fire barriers

-

Horizontal

-

Manufacturer guidance

Insert requirements.

Vertical

-

Manufacturer guidance

Insert requirements.

Cladding panels

-

Material

Aluminium cassette panels.

Panel joints

Open joints.

Samples required

None.

Panel and finish samples.

Samples of fixings.

Fabrication samples.

Mock-up to validate details.

Guidance for specification option:

Insert required size and details.

Configuration

Horizontal.

Vertical.

Horizontal and vertical.

Horizontal corner section

Required.

Not required.

Panel length

Guidance for specification option:

Available up to 6000 mm; insert requirements.

Fire classification (EN 13501-1)

A1.

Finish

Anodized.

Coil-coat.

Guidance for specification option:

25 micron minimum. Gloss level 25/40%.

Colour

-

Manufacturer guidance

An extensive range of colours available. Consult manufacturer and insert requirements.

Thickness

3 mm.

Joint width

-

Manufacturer guidance

Insert requirements, 10–20 mm.

Sheeting rails

Continous rails.

Individual rails.

Rail material/ finish

To EN 755, extruded aluminium, 6063/T6 grade alloy.

Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Recyclability

100

Third party certifications

CWCT Certificate

CWCT Certificate

CWCT - Technical Report

CWCT Certificate

CWCT Certificate

CWCT - Testing Report

Literature

Metalline Unity Brochure - Commercial

Metalline Unity Brochure - Commercial

Metalline Unity Brochure - Offices

Metalline Unity Brochure - Offices

Metalline Unity Brochure - Residential

Metalline Unity Brochure - Residential

Unity A1 DF-01 Technical Drawing

Unity A1 DF-01 Technical Drawing

Unity A1 DF-02 Technical Drawing

Unity A1 DF-02 Technical Drawing

Unity A1 DF-03 Technical Drawing

Unity A1 DF-03 Technical Drawing

Unity A1 DF-04 Technical Drawing

Unity A1 DF-04 Technical Drawing

Unity A1 DF-05 Technical Drawing

Unity A1 DF-05 Technical Drawing

Unity A1 DF-06 Technical Drawing

Unity A1 DF-06 Technical Drawing

Unity A1 DF-07 Technical Drawing

Unity A1 DF-07 Technical Drawing

Unity A1 DF-08 Technical Drawing

Unity A1 DF-08 Technical Drawing

Unity A1 DF-09 Technical Drawing

Unity A1 DF-09 Technical Drawing

Similar products from Metalline Architectural Fabrications

Unity DF A2 (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity DF A2 (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity FP A1 (folded plank) Aluminium Rainscreen

Unity FP A1 (folded plank) Aluminium Rainscreen

Unity FP A2 (folded plank) Aluminium Rainscreen

Unity FP A2 (folded plank) Aluminium Rainscreen

Unity IL A1 (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity IL A1 (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity IL A2 (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity IL A2 (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity PS A1 (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity PS A1 (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity PS A2 (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity PS A2 (Interlocking Plank & Soffit System) Non-Combustible Aluminium Rainscreen Cladding

Unity SF A1 (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity SF A1 (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity SF A2 (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding - Rainscreen Cladding

Unity SF A2 (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding - Rainscreen Cladding

Unity TF A1 (Through Fix) Non-Combustible Aluminium Rainscreen Cladding

Unity TF A1 (Through Fix) Non-Combustible Aluminium Rainscreen Cladding