Lightweight sliding stacking panel partition.

Features:

  • Individually operated, top hung panels, purpose made to suit any opening size.
  • Retractable top and bottom seals, mechanically operated by worm screw drive.
  • No floor track.
  • Faceted layouts, corner panels, junction panels, glazing cutouts and pass doors available.
  • Suitable for internal use only.

General information
Features

Individually operated, top hung panels, purpose made to suit any opening size

Retractable top and bottom seals, mechanically operated by worm screw drive

No floor track

Faceted layouts, corner panels, junction panels, glazing cutouts and pass doors available

Suitable for internal use only

Uniclass 2015 Sliding stacking panel partitions (Pr_25_71_57_80)
Specification data
Product Reference

Type 80

Partition assembly

See manufacturer drawings SL - 101, SL - 801 and SL – 802.

FireRating

None

Standard.

30 minute fire rated (no pass door)

60 minute fire rated (no pass door)

Acoustic insulation

Rw 41 dB

Rw 44 dB

Rw 46 dB

Rw 48 dB

Rw 50 dB

Rw 52 dB

Rw 53 dB

Rw 55 dB

Stacking layout

TL 1 ‘E’ system

Single point suspension.

TL 2 ‘Za’ system

Two point suspension.

TL 3 ‘Zb’ system

Two point suspension.

TL 4 ‘Z’ system

Stacked in recess cupboard, two point suspension.

TL 5 ‘K’ system

Two point suspension.

TL 6 ‘K’ system

Stacked behind reveal, two point suspension.

TL 7 ‘K’ system

Stacked inside wall recess, two point suspension.

TL 8 ‘K’ system

Stacked in branches to one or both sides, two point suspension.

Bunching

Single stack

Double stack

Bi - parting

Track profile -
Ceiling angle trim

None

Flush with underside of ceiling

Two point suspension only.

Exposed 20 mm from underside of ceiling

Single point suspension only.

Track finish

White

As standard, spray painted.

Other RAL colour

Spray painted, special order; insert requirement.

Wall jamb

Finished to match panels

Panel -
Panel Type

NE (Standard panel)

TE (Telescopic element)

SE1 (Single inset pass door)

SE2 (Double inset pass door)

EE (Corner/ junction panel)

DT (Full height hinged pass door)

Panel size -
Height

Up to 6 m; insert requirements.

Width

Up to 1230 mm as standard, wider panels possible to special order; insert requirements.

Finish

Priming sheet ready for ‘on site’ decoration by others

Insert details as required.

Standard laminate

High pressure laminate

Whiteboard laminate

Magnetic whiteboard laminate

Factory spray paint to RAL colour

Insert requirement.

Veneer

Insert details of species type and cut.

Client supplied fully finished boards

Insert details as required.

Lacquered steel sheet to RAL colour

Insert requirement.

Stretch fabric system

Thickness and fabric specification by specifier; insert details as required.

Perforated sound absorbent board

Perforation specification by specifier; insert details as required.

Slotted sound absorbent board

Slot specification by specifier; insert details as required.

Back painted glass

Magnetic back painted glass

Edge profile

Exposed

Concealed

Panel vertical edge trim finish

Satin anodized aluminium

Standard.

Powder coated aluminium to RAL colour

Insert requirement.

Vision panel

Not required

Required

See ‘Options’ for details and insert requirements Not available for NE (Standard panel), EE (Corner/ junction panel) or TE (Telescopic element).

Standard product features

Operation:

Manual; operated by worm screw drive.

Panels:

Aluminium frame with double skin cladding of high density chipboard.

Product Options

Partition assembly:

Refer to drawing for disposition of specified elements.

Acoustic insulation:

  • Rw 41 dB: Weight: 26 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.
  • Rw 44 dB: Weight: 30 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.
  • Rw 46 dB: Weight: 35 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.
  • Rw 48 dB: Weight: 40 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.
  • Rw 50 dB: Weight: 50 kg/m²; Thickness: 85 mm with exposed edge profiles, 93 mm with concealed edge profiles.
  • Rw 52 dB: Weight: 52 kg/m²; Thickness: 100 mm with concealed edge profiles.
  • Rw 53 dB: Weight: 53 kg/m²; Thickness: 100 mm with concealed edge profiles.
  • Rw 55 dB: Weight: 55 kg/m²; Thickness: 100 mm with concealed edge profiles.

Acoustic performance:

  • Can be used to limit noise transmission between rooms, using optional dense cladding, optional internal insulation. Type 80 panels have been tested to achieve sound reduction ratings of up to Rw 55 dB, measured in accordance with EN ISO 140-3. Insulation typically related to panel weight. Average achieved site insulation typically less than laboratory conditions, due to flanking structures.
  • Can be used to control room sound absorption levels using optional fabric wrapped acoustic panels or optional perforated/slotted sound absorbent boards.

Stacking layout:

- TL 1 ‘E’ system:

Straight runs only, panels stacked within opening. Single track, single point suspension.

- Z systems:

Straight runs only. Twin point guide roller suspension.

  • TL 2 ‘Za’ system: Minimal panel stack.
  • TL 3 ‘Zb’ system: Panels stacked within opening to left or right of track.
  • TL 4 ‘Z’ system: Stacked in recess cupboard.

- K systems:

For 90° movement of panels away from main track, twin point cross roller suspension.

  • TL 5 ‘K’ system: Two point suspension.
  • TL 6 ‘K’ system: Stacked behind reveal, two point suspension.
  • TL 7 ‘K’ system: Stacked inside wall recess, two point suspension.
  • TL 8 ‘K’ system: Stacked in branches to one or both sides.

Track profile:

  • Selection of material and profile by manufacturer, dependent on panel weight and other parameters. Consult manufacturer to confirm size.
  • Ceiling angle trim allows support of suspended ceiling edge.
  • 20 mm exposed angle trim required to avoid partition panels fouling ceiling when using TL 1 ‘E’ system single point suspension.

Panel:

- Type:

Where panel varies within the partition assembly, insert identifiers for panels after each selection.

  • TE (Telescopic element): Telescopic closure panel. One TE panel required at end of run for each opening.
  • SE1 (Single leaf inset pass door): Select from: no vision panel / with vision panel to client dimensions.
  • SE2 (Double leaf inset pass door): Includes head panel and jamb on hinge side of door. Select from: no vision panel / with vision panel to client dimensions.
  • EE (Corner/ junction panel): Corner, angle or T-junction panel.
  • DT (Full height hinged pass door): Fixed element, at end of run only. Includes jamb fixed to wall on hinge side of door. Select from: no vision panel / with vision panel to client dimensions.

- Finish:

Where panel finish varies within the partition assembly, insert identifiers for panels after each selection.

- Vision panel:

  • Glazed panel, cut out to client dimensions.
  • Minimum margins apply; consult manufacturer for details.
  • Available with integral blinds.

- Fire performance:

  • Available with optional fire separation construction. Particular fire rating may not be available in all panel types and finishes. Consult manufacturer prior to specification.
  • Available with optional finishes from standard range rated Class 1 Surface Spread of Flame when tested to BS 476 or Class O, in accordance with Building Regulation Approved Document B.

Similar products from London Wall Design Ltd