Single layer reinforced bitumen membrane roof covering.
Single layer torch-applied system of high performance elastomeric SBS-modified bitumen membrane. The product has special stripes on the underside to provide a partial bond and allow dispersion of trapped vapour. The membrane is intended for use as an overlay of existing bituminous or asphalt roofs in refurbishment situations. It is used in conjunction with an underlay and capsheet to form fully bonded details.
ThermoSolo is a single layer torch-on mineral capsheet manufactured on a strong polyester reinforcement coated on both sides with SBS polymer modified bitumen. The underside is finished with a specially blended bitumen stripe pattern interplaced with Red Syntan® and a finish of thermofusible film.
The stripe pattern provides vapour equalisation from entrapped moisture in the substrate avoiding blistering. The upper surface is finished with slate granules providing a decorative appearance and UV resistance.
Uniclass | |
CAWS | J41/135 Single-layer reinforced bitumen membrane cold deck roof covering |
Product Reference | ThermoSolo Roofing System |
Preparation | Icopal Siplast Bitumen PrimerGuidance for specification option: quick drying bituminous primer. Icopal SF Bitumen PrimerGuidance for specification option: solvent-free bituminous primer. |
Top layer/ Capsheet | ThermoSolo single-layer membraneGuidance for specification option: Torch-applied layer with partial bond stripes on underside and mineral finish topside. |
Flashings and detail work | |
Underlay | Premium SBS Torch-on UnderlayGuidance for specification option: Torch-applied underlay. |
Capsheet | Tecnatorch SBS MineralGuidance for specification option: Torch-applied detailing capsheet. |
Accessories | NoneIcopal Lightning Conductor PadsIcopal GRP Edge TrimsIcopal Roofgard Cable and Tube DuctIcopal Roofgard Cowled Telescopic VentIcopal Roofgard OutletIcopal Roofgard Parapet Outlet |
Standard product features | Colour: Charcoal Green |
Product Options | Preparation: Consult with Icopal Ltd for details of the preparation and priming of the intended roof structure and substrate and for details of the requirements for preparation layers, venting layers, nailing layers and taping strips. System build-up: Consult Icopal Limited’s technical literature for details and guidance. Icopal Limited are also able to offer a design and specification service and it is recommended that they are consulted early in the design process. |
Profiles T.A. Cold Roofing System
Profiles XL Cold Deck System
Profiles XL FireSmart Plus System - Cold Roof / Heated / Full Bond - System Number 17
Profiles XL FireSmart Plus System - Cold Roof / Heated / Partial Bond - System Number 15
Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Full Bond - System Number 16
Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Partial Bond - System Number 14
Total Torch Inverted Cold Deck Roofing System