BBA Agrément Certificate
Certificate type
QA Certificate
Certificate type
Torch-on, two layer, APP modified bitumen felt waterproofing system.
Torch-on, APP modified bitumen felt waterproofing system for flat or pitched roofs.
Resistance to traffic:
System accepts limited foot traffic associated with maintenance or construction.
Fire performance to BS 476:
When used for flat roofs with one of the surface finishes defined in part 3 of Table A5 of Appendix A of Approved Document B of the Building Regulations (England and Wales) the roof is deemed to be of designation EXT.F.AA.
Adhesion/ Fixing:
Uniclass 2015 | |
CAWS | J41/10 Built-up reinforced bitumen membrane warm deck roof covering J41/110 Built-up reinforced bitumen membrane warm deck roof covering J41/12 Built-up reinforced bitumen membrane cold deck roof covering J41/120 Built-up reinforced bitumen membrane inverted roof covering J41/130 Built-up reinforced bitumen membrane cold deck roof covering |
Product Reference | System 17000 Roofing |
Layout | As drawing ___ |
Preparation | Not requiredF-604-HP25, AMC high penetration bitumen primerA-12200, System 12000 preparation layer, secured by ___Rough or uneven substrates: secure by torching. Close boarded timber decks: secure with 15 mm galvanized clout nails at 150 mm centres. F-611-TO15, 15 mm Perlite recovery boardAccommodates uneven substrates: for torch-on membranes. |
Vapour barrier | Not requiredF-605, LaminalFor mechanical fix or torch-on application. |
Insulation | - |
Type | Not requiredE-PIRFTF, Sure-therm polyisocyanurate felt/ tissue faced, thickness ___ mmE-PIRPEF, Sure-therm polyisocyanurate perlite faced, thickness ___ mmE-EPSBFF, Sure-therm expanded polystyrene felt faced, thickness ___ mmE-XPSUNF, Sure-therm extruded polystyrene unfaced, thickness ___ mmFor inverted roof applications only. PIR, polyisocyanurate, tapered to ___ fallsStandard falls 1:80, 1:60, 1:40. Non standard falls available. EPS, Sure-therm expanded polystyrene, tapered to ___ fallsStandard falls 1:80, 1:60, 1:40. Non standard falls available. |
Fixing/ Adhesion | Torching to top surface of Laminal vapour barrierBonding with hot bitumenF-612, Sure-bond expanding foam adhesiveAdhesive fix insulation over very uneven substrates. F-621, Sure-bond PU adhesiveAdhesive fix insulation. F-701 Sure-fix insulation tube washer and F-710 fastenerSteel deck. F-701 Sure-fix insulation tube washer and F-712 fastenerTimber deck. F-702 Sure-fix insulation tube washer and F-711 fastenerConcrete deck. F-705, Sure-fix adjustable insulation fastener, concrete deckFor fixing tapered insulation to concrete deck Loose laid and ballastedFor inverted roof applications with XPS insulation only. |
Venting | Not requiredF-609, Polyfor venting layerEnables free movement of vapour to prevent blistering of felt system. |
Underlay | - |
Type | Not requiredC-17300, System 17000 underlaySuitable for full or partial bonding by torching or mechanical fixing. C-173SB, System 17000 self bond underlayLoose lay, bonds to substrate when capsheet is applied by torching. Available with 10 or 15 year guarantee only. |
Fixing | F-703 Sure-fix membrane tube washer and F-710 fastenerWarm roof fixings for steel deck. F-703 Sure-fix membrane tube washer and F-712 fastenerWarm roof fixings for timber deck. F-704, Sure-fix membrane tube washer and F-711 fastenerWarm roof fixings for concrete deck. F-706, Sure-fix adjustable membrane fastenerFor fixing over tapered insulation to concrete deck. F-713, Sure-fix preassembled cold roof fastenerCold roof fixings for timber deck. F-714, Sure-fix cold roof fastener and F-720 pressure plateCold roof fixings for steel/ timber deck. |
Capsheet | C-17400, System 17000 sanded capsheetRequires further surface protection. C-17450, System 17000 green mineral capsheetDoes not require further surface protection. System 17000 mineral finish capsheet, other colour ___Colours: black (charcoal), tweed (red/ brown), blue/ grey (violet), white. Special order subject to minimum quantity and lead time. Does not require further surface protection. |
Surface protection | Not requiredBailey AMC Aluminium SHRSolar heat reflective protection coating. F-618, Bailey paving support pads, rubber10 mm high x 120 mm diameter. Adjustable supports available. F-619, Bailey polyethylene geotextile membraneFor inverted roof applications, to be laid over XPS insulation. |
Accessories | NoneF-100-C Sure-line preformed drip edge, face ___ mmSpecial order. Face: 70 mm. F-150-C Sure-line preformed watercheck edgeSpecial order. Face: 90 mm. F-200-C Sure-line preformed upstand flashingSpecial order. 200 x 200 mm. F-250-C Sure-line preformed wall cover flashingSpecial order. Face: 85 mm. F-275, Bailey GRP edge trimFor watercheck or parapet edge trims. Colours: black, white or grey. Size: 40, 65, 100 or 150 mm face. Length: 3 m. F-602 Sure-fix GRP termination barSecures membrane edge to vertical surfaces, instead of using Sure-line or lead flashing. Use with F-603 foam tape, F-730 or F-740 fixings and F-616 mastic sealant. F-603 Bailey expanding foam tapeAccommodates substrate movement at termination bar. F-610, Bailey angle filletsFor upstands and abutments. F-616, Bailey silicone mastic, colour ___Colours: grey, translucent. Code 4 lead cover flashing , by othersNot supplied by Bailey. Chased into masonry joints and dressed over vertical edge of membrane. F-714, Sure-fix flashing fastenerSteel or timber substrate. F-716, Sure-fix flashing rivetMasonry substrate. F-730, Sure-fix termination bar fastenersTimber substrate. F-740, Sure-fix termination bar fastenersMasonry substrate. |
Other requirements | NoneF-617-02 - Lightning conductor clipsFor 25 x 3 mm bare tape. Special order. Install at 1 m centres. F-617-04 - Lightning conductor clipsFor 25 x 3 mm PVC coated tape. Special order. Install at 1 m centres. Bailey Sure-dome polycarbonate rooflightsAvailable in a variety of shapes, sizes and glazing options Bailey Sure-vault barrell vault rooflightsPurpose made item to special order. |
Product Options | Layout: Indicate outlets and penetrations. Indicate fixing layout for high rise or exposed buildings. Windload calculations and fixing layout proposal can be provided by Bailey. Indicate maintenance walkways. Indicate route of lightning conductor, if any. Vapour barrier: - F-605, Laminal:
Insulation: - Polyisocyanurate (PIR):
- Expanded polystyrene (EPS): E-EPSBFF, expanded polystyrene felt faced: (CFC and HCFC-free, zero ODP/GWP). For built up/ torch on felt roofs, fully or partially bonded. 100% recyclable. Requires greater thicknesses for equivalent U-value compared to PIR. - Extruded polystyrene (XPS): E-XPSUNF, Bailey Sure-therm extruded polystyrene unfaced: For inverted roof applications only. This type of insulation has a high compressive strength and high moisture resistance, making it suitable for use on roofs with extensive trafficking, heavy loads/ surface finishes and inverted roof applications. - Tapered Insulation (all types):
- Insulation Fixings/ Adhesion:
- F-609 Polyfor venting layer:
Underlay: – 17300 underlay:
Capsheet: – 17400 sanded capsheet:
– 17450 mineral capsheet:
Accessories: - Edges:
- Outlets and vents: For compatible rainwater outlets and roof vents, see Bailey Flow-therm or Sure-flow Outlets and Vents With Felt Flanges. - Rooflights:
Systems: – System 17000 for application to plywood deck (cold roof):
– System 17000 for application to concrete deck (warm roof):
– System 17000 for application to metal deck (warm roof):
|