NBS Source
List your products
System 17000 Plus Roofing
Description

Torch-on, single layer, PAO bitumen felt waterproofing system for flat or pitched roofs.

  • Single layer system with two layers at perimeters and details. Suitable for new build and refurbishment projects including overlays.
  • Capsheet: Tear resistant spunbond polyester carrier, coated with mix of poly alpha olefin (PAO) modified bitumen, plasticisers and fillers.
  • PAO modification gives excellent heat resistance and cold temperature flexibility.
  • Life expectancy in excess of 30 years.
  • Single layer reduces amount of labour required, making a cost effective flat roof system.
  • Choice of 10, 15 or 20 year insurance backed guarantee or 15 year manufacturer's guarantee on application, subject to installation and inspection by Bailey. Consult manufacturer.
  • Installation by recommended contractors.
  • Supplier offers system design, including wind load, U-value and flat roof drainage calculations.

Resistance to traffic:

System accepts limited foot traffic associated with maintenance or construction.

Adhesion/ Fixing:

  • Adhesion of system elements to one another and to substrates needs to be sufficient to resist wind suction and building movement. Bailey can provide windload calculations if required.
  • System is applied by melting polythene lower surface and bitumen lower surface by torching and pressure.
  • Falls in excess of 5º: Requirements for mechanical fixing to BS 8217 should be observed.

General information
Uniclass 2015
Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary
CAWS

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

J41/125 Single layer reinforced bitumen membrane inverted roof covering

J41/12 Built-up reinforced bitumen membrane cold deck roof covering

J41/115 Single layer reinforced bitumen membrane warm deck roof covering

J41/10 Built-up reinforced bitumen membrane warm deck roof covering

J41/135 Single layer reinforced bitumen membrane cold deck roof covering

Specification data - Reinforced bitumen membrane warm roof covering systems
Product Reference

System 17000 Plus Roofing

Layout

As drawing ___

Preparation

Not required

F-604-HP25 AMC high penetration bitumen primer

A-12200, System 12000 preparation layer,secured by ___

Rough or uneven substrates: secure by torching. Close boarded timber decks: secure with 15 mm galvanized clout nails at 150 mm centres.

F-611-TO15,15 mm Perlite recovery board

Accommodates uneven substrates: for torch-on membranes.

Vapour barrier

Not required

F-605, Laminal

For mechanical fix or torch-on application.

Insulation -
Type

Not required

E-PIRFTF, Sure-therm polyisocyanurate felt/ tissue faced, thickness ___ mm

E-PIRPEF, Sure-therm polyisocyanurate perlite faced, thickness ___ mm

E-EPSBFF, Sure-therm expanded polystyrene felt faced, thickness ___ mm

E-XPSUNF, Sure-therm extruded polystyrene unfaced, thickness ___ mm

For inverted roof applications only.

PIR, polyisocyanurate, tapered to ___ falls

Standard falls 1:80, 1:60, 1:40. Non standard falls available.

EPS, Sure-therm expanded polystyrene, tapered to ___ falls

Standard falls 1:80, 1:60, 1:40. Non standard falls available.

Fixing/ Adhesion

Torching to top surface of Laminal vapour barrier

Bonding with hot bitumen

F-612, Sure-bond expanding foam adhesive

Adhesive fix insulation over very uneven substrates.

F-621, Sure-bond PU adhesive

Adhesive fix insulation.

F-701 Sure-fix insulation tube washer and F-710 fastener

Steel deck.

F-701 Sure-fix insulation tube washer and F-712 fastener

Timber deck.

F-702 Sure-fix insulation tube washer and F-711 fastener

Concrete deck.

F-705, Sure-fix adjustable insulation fastener

For fixing tapered insulation to concrete deck.

Loose laid and ballasted

For inverted roof applications with XPS insulation only.

Venting

Not required

F-609, Polyfor venting layer

Enables free movement of trapped vapours to prevent blistering of felt system.

Capsheet -
Type

C-17520, System 17000 Plus, green mineral capsheet

Does not require further surface protection.

System 17000 Plus mineral finish capsheet, other colour ___

Colours: black (charcoal), tweed (red/ brown), blue/ grey (violet), white. Special order subject to minimum quantity and lead time. Does not require further surface protection.

System 17000 Plus sanded finish capsheet

Special order subject to minimum quantity and lead time. Requires further surface protection.

Fixing/ Adhesion

Torch applied.

Surface protection

Not required

Bailey AMC Aluminium SHR

Solar heat reflective protection coating.

F-618, Bailey paving support pads, rubber

10 mm high x 120 mm diameter. Adjustable supports available.

F-619, Bailey polyethylene geotextile membrane

For inverted roof applications, to be laid over XPS insulation.

Fixing/ Adhesion

Torch applied.

Accessories

None

C-17300, System 17000 underlay

For perimeter details and flashings only.

F-100-C Sure-line preformed drip edge, face ___ mm

Special order. Face: 70 mm.

F-150-C Sure-line preformed watercheck edge

Special order. Face: 90 mm.

F-200-C Sure-line preformed upstand flashing

Special order. 200 x 200 mm.

F-250-C Sure-line preformed wall cover flashing

Special order. Face: 85 mm.

F-275, Bailey GRP edge trim

For watercheck or parapet edge trims. Colours: black, white or grey. Size: 40, 65, 100 or 150 mm face. Length: 3 m.

F-602 Sure-fix GRP termination bar

Secures membrane edge to vertical surfaces, instead of using Sure-line or lead flashing. Use with F-603 foam tape, F-730 or F-740 fixings and F-616 mastic sealant.

F-603, Bailey expanding foam tape

Accommodates substrate movement at termination bar.F-610, Bailey angle fillets- For upstands and abutments.

F-616, Bailey silicone mastic, colour ___

Colours: grey, translucent.

Code 4 lead cover flashing, by others

Not supplied by Bailey. Chased into masonry joints and dressed over vertical edge of membrane.

F-714, Sure-fix flashing fastener

Steel or timber substrate.

F-716, Sure-fix flashing rivet

Masonry substrate.

F-730, Sure-fix termination bar fasteners

Timber substrate.

F-740, Sure-fix termination bar fasteners

Masonry substrate.

Other requirements

None

F-617-02

Lightning conductor clips - for 25 x 3 mm bare tape. Special order. Install at 1 m centres.

F-617-04

Lightning conductor clips - for 25 x 3 mm PVC coated tape. Special order. Install at 1 m centres.

Bailey Sure-dome polycarbonate rooflights

Available in a variety of shapes, sizes and glazing options

Bailey Sure-vault barrell vault rooflights

Purpose made item to special order.

Product Options

Layout:

Indicate outlets and penetrations. Indicate fixing layout for high rise or exposed buildings. Windload calculations and fixing layout proposal can be provided by Bailey. Indicate maintenance walkways. Indicate route of lightning conductor, if any.

Vapour barrier:

- F-605, Laminal:

  • SBS bitumen based, with aluminium core.
  • Suitable for torching both sides for bonding to substrate and bedding of insulation boards.
  • Suitable for mechanical fixing with laps hot air welded and insulation mechanically fixed or adhesive fixed to sanded top surface.
  • Suitable for high performance felt or single ply systems.

Insulation:

- Polyisocyanurate (PIR):

  • E-PIRFTF, polyisocyanurate felt/ tissue faced: (CFC and HCFC-free, zero ODP). For built up/ torch on felt roofs, fully or partially bonded or asphalt. Suited to most applications, including refurbishment. Compatible with most other building materials.
  • E-PIRPEF, polyisocyanurate perlite faced: (CFC and HCFC-free, zero ODP). Fire resistant. For torch on felt roofs, fully bonded. Suited to most applications, including refurbishment. Compatible with most other building materials.

- Expanded polystyrene (EPS):

E-EPSBFF, expanded polystyrene felt faced: (CFC and HCFC-free, zero ODP/GWP). For built up/ torch on felt roofs, fully or partially bonded..100% recyclable. Requires greater thicknesses for equivalent U-value compared to PIR.

- Extruded polystyrene (XPS):

E-XPSUNF, Bailey Sure-therm extruded polystyrene unfaced: For inverted roof applications only. This type of insulation has a high compressive strength and high moisture resistance, making it suitable for use on roofs with extensive trafficking, heavy loads/ surface finishes and inverted roof applications.

- Tapered Insulation (all types):

  • EPS, expanded polystyrene, tapered to falls: Use where substrate is flat or ponded.
  • PIR, polyisocyanurate, tapered to falls: Use where substrate is flat or ponded.

- Insulation Fixings/ Adhesion:

  • F-710, F-711, F-712, Bailey Sure-fix fasteners with F-701 or F-702 Sure-fix tube washers. Not required where top surface of Laminal vapour barrier is to be torched and boards bedded in or adhered.
  • F-705, Sure-fix adjustable insulation fasteners for fixing tapered insulation to concrete decks. Not required where top surface of Laminal vapour barrier is to be torched and boards bedded in or mechanically fixed.
  • F-612, Sure-bond expanding foam adhesive for bonding insulation to very rough or uneven substrates. For most applications F-621 is suitable. Not required where top surface of Laminal vapour barrier is to be torched and boards bedded in or mechanically fixed.
  • F-621, Sure-bond PU adhesive for insulation board. Not required where top surface of Laminal vapour barrier is to be torched and boards bedded in or mechanically fixed. Applied in 15mm strips, minimum 4 per metre. Application (minimum): 100-300 g/ m², increased at perimeter and corners.

Venting:

- F-609 Polyfor venting layer:

  • Perforated bitumen felt for loose lay beneath underlay. Enables partial bonding of underlay to substrate.
  • Allows free movement and dispersion of trapped vapour to prevent blistering of the felt system.

Capsheet:

– 17520 mineral capsheet:

  • Green/ grey slate mineral finish. Spunbond polyester carrier. Sacrificial polythene film backing.
  • Thickness: 4 mm.
  • Roll width x length: 1 x 8 m.
  • Weight: 5.6 kg/ m².
  • Suitable as single layer waterproofing or single layer overlay for repair of existing felted roofs.

Accessories:

– 17300 underlay:

  • For perimeters, flashings and details.
  • Bonded by torching.
  • 150 g/ m² spunbond polyester base. Sacrificial polythene film backing.
  • Thickness: 3 mm.
  • Roll width x length: 1 x 10 m.
  • Weight: 3.3 kg/ m².

- Edges:

  • Upstand flashings: Use underlay and mineral capsheet. Minimum 150 mm high with lead cover flashing or termination bar and expanding tape. Minimum 200 mm overlap to roof covering, fully torched to upstand and field sheet.
  • Sure-line: Rapid installation preformed trims for vulnerable roof edges, including draining edges, upstands and waterhcecks/ parapets. Galvanized steel angle with factory applied mineral felt membrane. 2 m lengths.
  • GRP edge trim: Glass reinforced plastic edge trim for waterchecks and parapets. Available in black, white or grey. Size: 40, 65, 100 or 150 mm. Length: 3 m. Internal and external preformed corners available.

- Outlets and vents:

  • For compatible rainwater outlets and roof vents, see Bailey Flow-therm or Sure-flow Outlets and Vents With Felt Flanges.

- Rooflights:

  • Bailey Sure-dome rooflights: Available square, rectangular and circular in a variety of sizes with domed, pyramid or trapezoidal, single/ double/ triple skin polycarbonate glazing. Glazing available with clear, opal diffused or bronze (anti-glare) finish. Rooflights also available as access/ escape hatches, with manual or automatic opening and manual or powered ventilation. Rooflights are mounted on curbs made from PVCu, GRP or aluminium with straight (vertical) or splayed (angled) sides. Security curb option also available.
  • Bailey Sure-vault barrel vault rooflights: Purpose made product for individual projects - contact Bailey for advice and options.

Systems:

– System 17000 Plus for application to plywood deck (cold roof):

  • Plywood deck with taped joints.
  • Bailey AMC bitumen primer.
  • Bailey System 17000 Plus mineral capsheet, fully bonded by torching.
  • Bailey System 17000 underlay (17300) for details.

– System 17000 Plus for application to concrete deck (warm roof):

  • Bailey AMC bitumen primer.
  • Bailey Laminal vapour barrier - fully bonded by torching.
  • Bailey Sure-therm PIR Insulation board.
  • Bailey Polyfor venting layer.
  • Bailey System 17000 Plus sanded capsheet, bonded by torching.
  • Bailey System 17000 underlay (17300) for details.
  • Paving slabs by others on Bailey paving support pads.

– System 17000 Plus for application to metal deck (warm roof):

  • Bailey AMC bitumen primer, applied to crowns of profiled deck.
  • Bailey Laminal vapour barrier - fully bonded by torching.
  • Bailey Sure-therm PIR Insulation board.
  • Bailey Polyfor venting layer.
  • Bailey System 17000 Plus mineral capsheet, bonded by torching.
  • Bailey System 17000 underlay (17300) for details.

Literature
Third party certifications
  • MPA (Germany) : Annual technical control report
  • CE mark: EN 13707 - EN 13969. Certificate No: 1370 - CPD - 0047 : Certificate of factory production control.
Similar products from Bailey - Total Building Envelope