Superglass Cladding Mat 32 is a non-combustible glass mineral wool insulation roll. For the walls and roofs of twin skin profiled metal clad systems and portable & modular buildings.

Jump to:
+44 (0)808 1645 134 Website

Application

Superglass Cladding Mat 32 is designed to provide thermal and acoustic insulation in the walls and roofs of twin skin profiled metal clad systems and portable & modular buildings.

Description

Superglass Cladding Mat 32 is a non-combustible glass mineral wool insulation roll. The roll is supplied 1200mm wide to suit commonly used rail and bracket systems.


Thermal Conductivity:

Declared thermal conductivity (lambda (λ) value) of 0.032W/mK.


Fire Classification:

Deemed non-combustible with a fire classification of Euroclass A1 (the highest possible rating) when tested to BS EN 13501-1 Reaction to Fire.


Vapour Resistivity

The product has a nominal vapour resistivity of 5 MN·s/g·m.


Environmental credentials.

  • Manufactured in accordance with ISO 14001 - Environmental Management Systems (EMS). Certificate number: EMS 646508.
  • Contains no ozone-depleting substances or greenhouse gases. For more information, please refer to the Environmental Product Declaration (EPD).
  • Made from up to 84% recycled glass.
  • Generic BRE Green Guide Rating of A+.
  • Our products and their pallets are wrapped in low-density polyethylene (LDPE4) plastic, which contains a minimum 30% recycled material and is fully recyclable. Before recycling, please consult your local authority for guidance.


Standards and Approvals.

  • BS EN 13162:2012(+A1:2015) Thermal insulation products for buildings - Factory made mineral wool (MW) products.
  • BS EN 13172: 2012 Thermal insulation products – Evaluation of conformity.
  • BS EN ISO 9001 - Quality Management Systems (QMS). Certificate number: FM 02264.


Certification:

  • UKCA certified to BS EN 13162:2012+A1:2015. Certificate number: 0086 CPR 469699.
  • CE marked to BS EN 13162:2012+A1:2015. Certificate number: 0751-CPR-399.0-01.

General information

Color

Yellow

Material

Glass mineral wool

Mineral fibre

Mineral wool

Width

1200 mm

Height

50 mm

60 mm

80 mm

90 mm

100 mm

Show more

Uniclass

Pr_25_57_06_53 Mineral wool insulationPrimary

Pr_25_57_06/310 Insulation products generally

Pr_25_57_06_34 Glass fibre insulation

CAWS

H61/230 Mineral wool insulation on structural metal liner trays

H60/230 Mineral wool insulation on structural metal liner trays

H67/305 Mineral wool insulation on structural metal liner trays

H65/230 Mineral wool insulation on structural metal liner trays

H64/305 Mineral wool insulation on structural metal liner trays

H62/230 Mineral wool insulation on structural metal liner trays

H31/271 Mineral wool thermal insulation

H31/254 Acoustic insulation

P10/15 Insulation fitted between rafters

B11/240 Thermal insulation

P10/190 Insulation fitted between studs

P10/140 Insulation fitted between rafters

Product range

Built-up Metal Clad Roofs & Walls Insulation
Glass Mineral Wool Insulation

Specification data - Mineral wool insulation

Standard

To BS EN 13162.

Guidance for specification option:

Manufactured in accordance with:

  • BS EN 13162:2012(+A1:2015) Thermal insulation products for buildings - Factory made mineral wool (MW) products.
  • BS EN 13172: 2012 Thermal insulation products - Evaluation of conformity.

Form

Glass mineral wool roll.

Thickness (minimum)

50 mm.

Width (nominal)

1200 mm.

Thermal conductivity (maximum)

0.032 W/m·K.

Fire performance

Reaction to fire classification of A1, as defined in BS EN 13501-1.

Guidance for specification option:

All Superglass products are deemed non-combustible and have a fire classification of A1 when tested to BS EN 13501-1 reaction to fire.

Recycled content

Up to 84%.

Guidance for specification option:

Manufactured from up to 84% recycled glass which would otherwise go to landfill.

Green guide rating

A+.

Length

6600 mm.

R-Value

1.55 m²K/W.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Glass mineral wool

Mineral fibre

Mineral wool

Manufacturing plant location

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

1.35 kg CO₂ eq/kg

Manufacturer guidance

Please see product EPD.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

84 %

Guidance for specification option:

Manufactured from up to 84% recycled glass which would otherwise go to landfill.

Expected Life

Lifetime

Third party certifications

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

EPD

EPD

Environmental Product Declaration (EPD) – Cured Glass Mineral Wool Insulation

CE Marking

CE Marking

CE Certificate - Cured Glass Mineral Wool Insulation

UK Conformity Assessed (UKCA)

UK Conformity Assessed (UKCA)

UKCA Certificate - Cured Glass Mineral Wool Insulation

BS EN 13501-1

BS EN 13501-1

Euroclass A1 Reaction to Fire Classification

ISO 9001 Quality Management

ISO 9001 Quality Management

Quality Management System ISO 9001:2015

DoP

DoP

Declaration of Performance (DoP) - Cladding Mat 32 - UKCA

Literature

Superglass Cladding Mat 32 - Datasheet

Superglass Cladding Mat 32 - Datasheet

Insulation Solutions Guide

Insulation Solutions Guide

Superglass Cladding Mat - Best Practice Guide

Superglass Cladding Mat - Best Practice Guide