Studio-Linked Rooflights

Verified by manufacturer 4 months ago

CR-1

The Rooflight Co. Variant:

Close-coupled run of Conservation Rooflights®, using linking bar system.

Jump to:
+44 (0)1993 833155 Website

Application

Suitable for pitched roof applications (17.5° - 65°) and can be incorporated into the roof ridge.

Description

Close-coupled run of Conservation Rooflights®, using linking bar system.


Features and benefits:

  • Achieves a close-coupled run of rooflights by means of a linking bar system.
  • Limitless runs of rooflights can be achieved.
  • Steel frames, with a protective polyester powder coating.
  • Include our unique Thermoliner® detail to minimise the risk of condensation and mould.
  • Silicone beading and fronting to the glazing resembles traditional putty in appearance.
  • Genuine glazing bars fitted as standard to most sizes.

General information

Color

Black

Guidance for specification option:

RAL9005.

Grey

Guidance for specification option:

Light Grey (BS00A09), Dark Grey (BS00A13).

White

Guidance for specification option:

RAL9010.

Other

Guidance for specification option:

As per manufacturer and includes all BS, RAL and special colours available on request.

Finish

Powder coated to BS EN ISO 12944

Material

Glass

Steel

Shape

Rectangle

Square

Warranty description

One year

Guidance for specification option:

On ancillary items.

Five year

Guidance for specification option:

On glass.

Ten year

Guidance for specification option:

On frames upon registration online. 

Uniclass

Pr_30_59_98_84 Steel frame roof window unitsPrimary

CAWS

L10/480 Roof windows

Product range

Rooflights for pitched roofs

Specification data - Steel frame roof window units

Product performance

-

Whole window U-value

1.4 W/m²K.

Frame

-

Finish as delivered

-

Coating

Polyester powder coating to BS EN ISO 12944.

Colour

Black (RAL 9005).

Dark Grey (BS 00A13).

Light Grey (BS 00A09).

White (RAL 9010).

Any BS.

Guidance for specification option:

Insert requirement.

Any RAL.

Guidance for specification option:

Insert requirement.

As drawing.

As schedule.

Glazing or infill

-

Standard

Relevant parts of BS EN 1279.

Composition

4 mm SGG Planilux Toughened Outer, 16 mm 90% Argon Cavity, 4 mm SGG Planitherm One II (Low E) Toughened Inner.

Guidance for specification option:

Producing a glass centre pane U value of 1.0 w/m²K.

Manufacturer guidance

Enhanced glazing specification incorporating thermal, acoustic, security, light transmission, passive solar gain and decorative options available.

Drained and vented rebate

Required.

Clips or tape

Required.

Beading

Silicone beading.

Operation

-

Type

Electric operation.

Electric chain actuator.

Electric linear actuator.

Electric rack actuator.

Hand winder.

Manual operation (within reach).

Manual operation (out of reach).

Pole winder and winding crank.

Fixing features

Linking bar system.

Accessories

Not required.

Flashing kit.

Guidance for specification option:

Suitable for most roof types. Insert requirement.

Dimensions

385 x 545 mm.

Manufacturer guidance

  • Sizes indicated are structural opening.
  • Any combination of same height rooflights can be linked together using the required linking bars.

Linking bar

L-1.

Glazing bar

Required.

Guidance for specification option:

As standard.

Not required.

Guidance for specification option:

On request.

Layout

As drawing.

As schedule.

Type

Not required.

Pleated Blind.

Roller Blind.

Manufacturer guidance

Blind type.

Style

Coma Collection.

Natural Plains.

Manufacturer guidance

Blind style.

Colour

White.

Guidance for specification option:

Available in all types.

Ivory.

Taupe.

Silver.

Dark Grey.

Show more

Manufacturer guidance

Blind colour.

Operation

Manual.

Electric.

Rod.

Manufacturer guidance

Blind operation.

FrameMaterial

Steel.

Other.

Guidance for specification option:

Different material specifications (e.g. stainless steel) are available for applications in industrial or maritime locations. Consult manufacturer for details.

Electric actuators

Guidance for specification option:

  • Power requirements: dependent on application.
  • The selection of actuator depends on the rooflight size and application.
  • Rain, temperature and smoke sensors are available on request.
  • An on/ off switch is required. Consult manufacturer for details.

Third-party certification

BSI Kitemark and KM 93754.