NBS Source
List your products

product no longer available -

Description

Masonry partitioning systems which provide Robust Detail Solutions. The systems incorporate GTEC gypsum board, fixings and finishing products. Suitable for use across many construction sectors, including commercial, residential, education and health. They offer a simple, lightweight, durable and versatile means of dry wall construction.

General information
Specification data
Product Reference

Siniat Masonry Robust Detail Systems

Partition type

E-WM-3

Overall thickness: 315 mm; Fire performance: 240 minutes.

E-WM-4

Overall thickness: 315 mm; Fire performance: 240 minutes.

E-WM-5

Overall thickness: 315 mm; Fire performance: 240 minutes.

E-WM-11

Overall thickness: 315 mm; Fire performance: 240 minutes.

System height

As drawing

Insert reference.

Jointing

Insert requirement(s) from manufacturer's literature.

Sealer

GTEC Drywall Sealer

Ivory, pre-decoration coat for plasterboard.

GTEC Universal Sealer

For use on plasterboard prior to painting for improved whiteness and covering power.

Standard product features

Total thickness:

315 mm.

Fire performance (to BS 476-22 and BS EN 1364-1):

240 minutes.

GTEC Standard Board:

  • Material: Aerated calcium sulfate di-hydrate enclosed inside a tough paper with bound edges. Core and papers are bonded with starch. PVA edge glue.
  • Size (w x l): 900–1200 x 1800–3000 mm.
  • Nominal weight: 5.95–10 kg/m².
  • Thermal resistance (R-value): 0.05–0.079 m²K/W.
  • Thermal conductivity: 0.19 W/mk.

GTEC Intumescent Acoustic Sealant:

Perimeter sealing to restrict smoke, sound and fire penetration. Ensures system performance.

GTEC Corner and Edge Beads:

Provides corner and edge reinforcement.

GTEC Socket Pad:

Maintains acoustic and fire integrity at sockets.

Fixings:

GTEC Universal Bonding Compound and GTEC Nailable Plugs.

Product Options

Partition type:

- E-WM-3:

  • Facing outer layers: One 12.5 mm-thick GTEC Standard Board both sides.
  • Lining: Sand cement render and GTEC Universal Bonding Compound to form 10 mm cavity.
  • Cavity: 75 mm.
  • Internal wall leaf: 100 mm blocks, 1850–2300 kg/m³ density (supplied by others).
  • External wall leaf: 100 mm blocks, 1850–2300 kg/m³ density (supplied by others).

- E-WM-4:

  • Facing outer layers: One 12.5 mm-thick GTEC Standard Board both sides.
  • Lining: GTEC E Coat Render GTEC Universal Bonding Compound to form 10 mm cavity.
  • Cavity: 75 mm.
  • Internal wall leaf: 100 mm blocks, 1350–1600 kg/m³ density (supplied by others).
  • External wall leaf: 100 mm blocks, 1350–1600 kg/m³ density (supplied by others).

- E-WM-5:

  • Facing outer layers: One 12.5 mm-thick GTEC Standard Board both sides.
  • Lining: Sand cement render GTEC Universal Bonding Compound to form 10 mm cavity.
  • Cavity: 75 mm.
  • Internal wall leaf: Star Performer Blocks (supplied by others).
  • External wall leaf: 100 mm Star Performer Blocks (supplied by others).

- E-WM-11:

  • Facing outer layers: One 12.5 mm-thick GTEC Standard Board both sides.
  • Lining: GTEC E Coat Render GTEC Universal Bonding Compound to form 10 mm cavity.
  • Cavity: 100 mm.
  • Internal wall leaf: 100 mm blocks, 1350–1600 kg/m³ density (supplied by others).
  • External wall leaf: 100 mm blocks, 1350–1600 kg/m³ density (supplied by others).

System height (maximum):

5.2 m.