Separating floor systems.
Widely used in the construction of both residential and commercial sector buildings.
Separating floor systems, widely used in the construction of both residential and commercial sector buildings. They can be used to cover a wide range of design objectives, including aesthetic, acoustics, environmental, safety and performance requirements.
Features and benefits:
They can be used to cover a wide range of design objectives, including aesthetic, acoustics, environmental, safety and performance requirements.
Application:
Widely used in the construction of both residential and commercial sector buildings.
Material | Dependent on system |
Uniclass 2015 | |
CAWS | K11/275 Acoustic separating floor system |
Product Reference | Siniat GTEC Separating Floor Systems |
Flooring | Dependent on system, consult manufacturer |
Fasteners | Dependent on system, consult manufacturer |
Joint treatment | Insert requirements from manufacturer's literature. |
Perimeter sealer | GTEC Drywall SealerIvory, pre-decoration coat for plasterboard. GTEC Universal SealerFor use on plasterboard prior to painting for improved whiteness and covering power. |
System accessories | NoneGTEC Resilient BarFor E-FT-1, RTC 050 only, 450 mm centres (maximum). |
Type | E-FC-1: (CT1) Metal Ceiling SystemGTEC MF Ceiling system providing 100 mm (minimum) ceiling void with one layer of 12.5 mm thick GTEC Standard Board. E-FC-1: (CT2) Timber Battens and Counter Battens50 x 50 mm softwood battens with 50 x 50 mm counter battens below and one layer of 12.5 mm thick GTEC Standard Board. E-FC-1: (CT3) Metal Ceiling SystemGTEC Dryliner SR or MF Ceiling System providing a 75 mm (minimum) ceiling void with one layer of ≥10 kg/m² GTEC Board. E-FC-1: (CT4) Timber Battens and Resilient Bar50 x 50 mm softwood battens with GTEC resilient bar RBD3000 mounted at 90° to softwood battens at 450 mm centres (maximum) and one layer of 12.5 mm thick GTEC E Board. E-FC-2: Metal Ceiling SystemGTEC Dryliner SR or MF Ceiling System providing a 75 mm (minimum) ceiling void with one layer of ≥10 kg/m² GTEC Board. E-FC-2: Timber Ceiling SystemAny ceiling system providing a 75 mm void with one layer of 12.5 mm thick GTEC E Board. E-FT-1: Robust DetailSystem weight: 72 kg/m²; Fire performance: 60 minutes. RCC 015 Modified: Refurbishment as Approved Doc. E 4-3System weight: 80 kg/m²; Fire performance: 60 minutes. RTC 025System weight: 70 kg/m²; Minimum thickness: 323 mm; Fire performance: 60 minutes; Acoustic performance: 61 dB sound reduction; Impact sound insulation: 54 dB. RTC 049System weight: 71 kg/m²; Fire performance: 60 minutes; Acoustic performance: 60 dB sound reduction; Impact sound insulation: 55 dB. RTC 050System weight: 71 kg/m²; Minimum thickness: 317 mm; Fire performance: 60 minutes; Acoustic performance: 60 dB sound reduction; Impact sound insulation: 55 dB. |
Ceiling | - |
Inner layers | Dependent on system, consult manufacturer |
Face layer | Dependent on system, consult manufacturer |
Insulation | None or 100 mm-thick 10.5 kg/m³ glass mineral wool (supplied by others)Dependant on flooring type selected. |
Cavity fire barriers | GTEC Intumescent Acoustic SealantPerimeter sealing to restrict smoke, sound and fire penetration. Ensures system performance. |
Structure | 47 x 200 mm joists at 450 mm centres (supplied by others) |
Standard product features | Material: Dependent on system. |