NBS Source
List your products
Siniat GTEC Lining Systems to New External Walls
Application

Fixing systems to walls for most typical substrates.

Description

Lining systems offering a wide range of plasterboard lining fixing systems to walls for most typical substrates.

Features and benefits:

Different depths of cavity spaces can be created between the GTEC Board or GTEC Thermal Board lining and underlying wall. These cavities hide services or help to achieve high levels of fire resistance, U-values and sound insulation.

Application:

Fixing systems to walls for most typical substrates.

General information

Features

Different depths of cavity spaces can be created between the GTEC Board or GTEC Thermal Board lining and underlying wall. These cavities hide services or help to achieve high levels of fire resistance, U-values and sound insulation

Material

Plasterboard, timber frame and glass fibre insulation

Size

System height dependent on system build up

Uniclass 2015

Ss_25_25_45_35 Gypsum board wall lining systemsPrimary

CAWS

K10/15 Lining on timber

K10/155 Wall lining system (metal studs)

K10/175 Wall lining system (metal furrings)

K10/205 Lining on timber

K10/30 Metal stud

K10/41 Wall lining on metal furrings

Specification data - Gypsum board wall lining systems

Product Reference

Siniat GTEC Lining Systems to New External Walls

Support

Gympsum based adhesive

Provides corner and edge reinforcement.

Insulation

None, glass fibre or expanded polystyrene (supplied by others to BS 5250) with GTEC Insulation Hold to secure and prevent slump

Dependent on lining type selected, various sizes.

Cavity fire barriers

GTEC Intumescent Acoustic Sealant

Perimeter sealing to restrict smoke, sound and fire penetration. Ensures system performance.

Linings

-

Inner layers

GTEC Dryliner Channel System

For RDS 103, RDS 104, RDS 108, RDS 109 and RDS 110 only.

GTEC Shallow Wall Channel

For RDL 101 and RDL 102 only.

GTEC Universal Bonding Compound

For RDL 101 and RDL 102 only.

Face layer

GTEC Thermal K Board, GTEC Standard Board or GTEC Vapour Board

Dependant on lining type selected, various thicknesses.

Fasteners

Dependent on lining

Joint treatment

Insert requirements from manufacturer's literature.

Type

RDL 101: Direct Bond or Shallow Channel

Minimum thickness: 325 mm; U-value: 0.3 W/m²K.

RDL 102: Direct Bond or Shallow Channel

Minimum thickness: 342 mm; U-value: 0.26 W/m²K.

RDS 103: Dryliner

U-value: 0.28 W/m²K.

RDS 104: Dryliner

U-value: 0.3 W/m²K.

RDS 108: Dryliner

U-value: 0.28 W/m²K.

RDS 109: Dryliner

U-value: 0.27 W/m²K.

RDS 110: Dryliner

U-value: 0.29 W/m²K.

Sealer

GTEC Drywall Sealer

Ivory, pre-decoration coat for plasterboard.

GTEC Universal Sealer

For use on plasterboard prior to painting for improved whiteness and covering power.

Socket integrity

GTEC Socket Pad

Maintains acoustic and fire integrity at sockets.

Standard product features

Features:

Different depths of cavity spaces can be created between the GTEC Board or GTEC Thermal Board lining and underlying wall. These cavities hide services or help to achieve high levels of fire resistance, U-values and sound insulation.

Material:

Plasterboard, timber frame and glass fibre insulation.

Size:

System height dependent on system build up.

Similar products from Siniat