A one-piece passive fire insulation product for sealing the cavities formed between the top of compartment walls and the underside of the construction above, preventing the spread of fire and smoke and reducing sound transmission.
It comprises a single, close dimensioned product with a unique pre-compressed internal stone wool mineral fibre lamella core.
It provides a seal between the top of the compartment wall, partition, or fire resistant suspended ceiling, and the structural soffit. The choice of material is determined by the performance requirement in terms of fire resistance (i.e. insulation and integrity) and size of cavity.
Features and benefits:
Uniclass 2015 | |
CAWS | P12/160 Linear gap sealing P12/360 Mineral wool rigid batts P12/40 Mineral wool rigid batts |
Product Reference | Siderise TW Firestops for Tops of Walls |
Type | TW-CB30Gap height (20–50 mm); 30 minutes fire rating. Gap + 10 (seal height) x 75 (thickness) mm. TW-FS6060 minutes fire rating. Gap + 10 (seal height) x 90 (thickness) mm. TW-FS120120 minutes fire rating. Gap + 10 (seal height) x 120 (thickness) mm. TW-CB30Gap height (20–50 mm); 30 minutes fire rating. Gap + 10 (seal height) x 75 (thickness) mm. TW-FS6060 minutes fire rating. Gap + 10 (seal height) x 90 (thickness) mm. TW-FS120120 minutes fire rating. Gap + 10 (seal height) x 120 (thickness) mm. TW-CB30Gap height (20–50 mm); 30 minutes fire rating. Gap + 10 (seal height) x 75 (thickness) mm. TW-FS6060 minutes fire rating. Gap + 10 (seal height) x 90 (thickness) mm. TW-FS120120 minutes fire rating. Gap + 10 (seal height) x 120 (thickness) mm. |
Fixing brackets | NoneB65/110Minimum void size: 50 mm. Maximum void size: 150 mm. B195Minimum void size: 151 mm. Maximum void size: 240 mm. B355Minimum void size: 241 mm. Maximum void size: 400 mm. |
Standard product features |
|
Product Options | Fixing brackets: Fixing brackets are not required for voids below 50 mm. For voids above 50 mm fixing brackets are incorporated into the assembly to maintain the integrity of the construction. They are simply impaled into the base of the barrier at mid-thickness prior to installation. Two brackets are required per unit. The standard fixing brackets are supplied in flat pre-notched form for folding on site to the requisite “L” or “Z” shape. They are pre-cut to a spike so that the long leg can penetrate into the barrier. Fire performance:
In terms of ‘Reaction to Fire’, the products provide the following: Class ‘A1’, in accordance with EN13501-1 and EC Decision 96/603/EC. |
SIDERISE BB-CB Balcony Bracket-Cavity Barriers
SIDERISE CVB Acoustic Void Barriers (formerly Lamaphon CVB)
SIDERISE CW-AB Acoustic Barrier Overlay - Facades (formerly Lamatherm CW-AB)
SIDERISE CW-FB curtain wall fireboard
SIDERISE CW-FS Perimeter Barriers and Firestops for Curtain Walling (formerly Lamatherm CW-FS)
Siderise EW - Cavity Barriers and Fire Stops for Masonry External Walls
SIDERISE NXR Nexus Lamella Boards – Curtain Walling (formerly Lamatherm NXR)
SIDERISE NXS Firesafe Spandrel Insulation (formerly Lamatherm NXS)
SIDERISE OSCI Open State Cassette Insert
SIDERISE RF Cavity Barriers and Firestops for Raised Access Floors (formerly Lamatherm RF)