Verified by manufacturer over a year ago
High Security Timber Doorset - SR4
Safeguard SR4 doors have been tested and certified to LPS 1175 SR4.
Safeguard Ultimum doors are designed for a range of applications where a higher standard of security is required, whilst still providing discreet attractive appearance.
Upgradable to BS EN 1634-1:2008
Additional information for this product is available from:
https://www.assaabloy.co.uk/en/local/uk/product/all-products/security-doors1/safeguard-timber-doorsets/security/certified-security/ultimum---lps-1175-sr4/
Uniclass | |
CAWS | L20/410 Wood doorsets L20/420 Wood doorsets L20/55 Doorsets |
Product range |
Product Reference | SR4 |
FireRating | Non fire ratedFD30Guidance for specification option: 30 minute integrity and insulation tested to BS EN 1634-1. FD60Guidance for specification option: 60 minute integrity and insulation tested to BS EN 1634-1. |
Facing | Ash veneerMahogany veneerOak veneerSteel |
Colour/ Finish | |
Door leaf | LacqueredPaintedStainedTwo-part resinGuidance for specification option: Special finish, consult manufacturer for more details. |
Door frame | LacqueredPaintedStainedTwo-part resinGuidance for specification option: Special finish, consult manufacturer for more details. |
Vision panel | Guidance for specification option: Insert requirements. |
Ironmongery | Guidance for specification option: Insert requirements. |
Hinges | |
Type | Solid stainless steel continuous hingeGuidance for specification option: Optional. Non-fire rated. Manufacturer's standard |
Locking | Concealed three point lockingSurface mounted three point locking |
Door closer | Guidance for specification option: Insert requirements. |
Standard product features | Door: - Leaf: Single and double leaf configuration. - Frame:
Ironmongery: - Hinges: Four heavy duty, fire rated, steel hinges. Additionally three hinge bolts providing greater strength and protection to hinge side of the door frame. - Locking:
|
Product Options | Vision panel: Vision panels can be fitted into the door core. The design will depend on the application, level of security required and limitations with regard to the fire certification. |