Rooftrak IFP-200 integrated fixing point system for cold roof constructions and fully supported membranes.
Typical uses include:
Suitable for use with the following roof covering types:
Rooftrak IFP-200 Integrated fixing point system for cold roof constructions and fully supported membranes, provides a structural connection whilst maintaining 100% integrity of the waterproofing layer.
Features and benefits:
Applications:
Typical uses include:
Suitable for use with the following roof covering types:
Size | Overall height: 45 mm Fixing plate: 200 x 200 x 3 mm. Distance between fixing threads: 52 mm |
Uniclass 2015 |
Product Reference | Rooftrak™ IFP-200 |
Main roof weathering material | See 'Options' below and insert requirements. |
Accessories | NoneDirect fixing suitable for roof structure10 mm shim, IFP-SHM10 bolt set, IFP-BSMovement bracket (straight), IFP-MB1Movement bracket (right-angle), IFP-MB2Universal bracket (straight), IFP-UB1Universal bracket (right-angle), IFP-UB2 |
Standard product features | Material/ Finish:
Size:
Load ratings: It is assumed that the IFP is fixed directly through the roofing membrane into the substrate below with 8 no. fixings and that the supporting structure has the capacity to support the design loadings likely to be encountered. - Compressive load: Maximum compressive load to be applied: 5.0 kN. - Shear load: Maximum shear load to be applied: 2.5 kN. - Tensile load: Note: Values are based on the Fixfast SF-RS-6.1 fastener as per European Technical Approval 15/0406 and allow a safety factor of three on the combined mean axial pullout value of eight fixings. For concrete substrates note that these are typical figures but should be verified by onsite pullout tests.
|
Product Options | Main roof weathering system: Select material for weathering flange from the list below, or consult manufacturer and insert appropriate details.
- Flange size: Consult manufacturer for details of materials not listed below.
Accessories: - Direct fixing suitable for roof structure: Direct fixing from plate to structural substrate.
- 10 mm shim, IFP-SH: Packing shim designed to fit over the anchor point where multiple anchor points need to be level. Can be used in multiples to achieve greater packing dimensions. Note that a longer bolt will be required to secure them to the anchor points: care should be taken in selecting the bolt length as the anchor points are blind threaded holes.
- M10 bolt set, IFP-BS: Standard bolt set for IFP products, comprising a pair of M10 hex bolts and washers. Suitable for bolting materials 0.5–10 mm thick (for >10 mm thickness, a longer bolt will be required).
- Movement bracket (straight), IFP-MB1/ Movement bracket, IFP-MB2 (right-angle): Connecting brackets designed for use with the IFP products. Fixing holes that allow it move to accommodate thermal expansion of the frame or support members fixed to it. For further details, including loading values, consult manufacturer.
- Universal bracket (straight), IFP-UB1/ Universal bracket (right-angle), IFP-UB2: Connecting brackets designed for use with IFP products. Fixing holes allowing it to be fixed in either axis and further adjusted to 15° either side of the chosen axis. Use in conjunction with IFP-BS bolt set. For further details, including loading values, consult manufacturer.
|