NBS Source
I'm a manufacturer
Compare variants

Skyway AOV Hinged Flat Glass Smoke Vent Rooflight

Verified by manufacturer 2 months ago

Skyway AOV Hinged Flat Glass Smoke Vent Rooflight, Hermetically Sealed Double Glazed - IGU

Roofglaze Rooflights Ltd Variant:
Third party certifications:
  • BRE Certificate

    BRE Certificate

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • DoP

    DoP

    Certificate type

A flatglass automatic opening vent (AOV) NSHEV rooflight.

Jump to:
BIM object icon
+44 (0)1480 474 797 Website

Application

For applications in commercial and residential buildings. Designed to be installed on flat roofs with no more than a 5° pitch.

Description

A Flatglass AOV (Automatic Opening Vent) NSHEV (Natural Smoke and Heat Exhaust Ventilation) rooflight manufactured to BS EN 12101-2 for heat and smoke ventilation. The smoke vents come in two standard sizes, which achieve a Geometric Free Area (GFA) of 1.0 m² and 1.5 m² respectively.


Features and benefits:

  • Powered by two 24 V concealed folding arm actuators.
  • Control Panel comes with electric lock, battery backup and 24v transformer.
  • Fully thermally broken aluminium frames prevent cold bridging, reducing the risk of condensation.
  • Fully insulated base frame provides excellent thermal efficiency.
  • Access and ventilation options.
  • Smoke, gas, wind, and rain sensors available.
  • Break glass and override switches available.
  • Full integration to building fire management system.
  • Excellent thermal performance, with total system U-values as low as 0.9 W/m²K achievable.
  • Quick and easy to install.
  • Minimal framework: daylight is maximized while the visible framework is minimized.
  • Can also be used for natural ventilation.
  • Can also be used for occasional access.
  • More daylight -> less artificial light -> energy savings.


Designed to standard loadings of 640 N/m² (snow) and 750 N/m² (wind) and in accordance with the following Standards:

  • BS 6375-1 2015+A1 2016: Weather tightness.
  • BS EN 1026: Air permeability.
  • BS EN 1027: Water tightness test.
  • BS EN 12211: Wind resistance test.
  • BS 1474: Aluminium Extrusions.
  • EN 12020-1:2001: Aluminium Extrusions.
  • BS EN ISO 16396-2:2017: Polyamide Thermal Break.
  • BS EN 12206-1:2004: Powder Coating.

General information

Color

Black

Grey

Other

Finish

Powder-coated

Material

Aluminium

Glass

Shape

Rectangle

Length

Bespoke

Guidance for specification option:

The external kerb sizes can be increased by adding a larger flashing detail, but do not reduce internal dims.

950 mm

1484 mm

Manufacturer guidance

These sizes are the minimum internal opening sizes. External kerb sizes can vary but internals have a minimum size limit due to testing and certification restrictions.

Width

Bespoke

Guidance for specification option:

The external kerb sizes can be increased by adding a larger flashing detail, but do not reduce internal dims.

1054 mm

Manufacturer guidance

These sizes are the minimum internal opening sizes. External kerb sizes can vary but internals have a minimum size limit due to testing and certification restrictions.

Height

Bespoke

Manufacturer guidance

Unit is approx. 385mm tall. Bespoke heights achievable by changing kerb heights.

Warranty description

15 year

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

L10/45 Rooflights

L10/460 Rooflights

Product range

Skyway

Specification data - Framed rooflights

Form

Flat.

Size

1.0 m² geometric free area (1344 x 1284 mm; 387 mm high).

1.5 m² geometric free area (1884 x 1284 mm; 387 mm high).

Manufacturer guidance

Overall kerb length x width; overall height.

Product performance

-

Fire performance

-

Reaction to fire

Euroclass A1 non-combustible.

Whole window U-value

0.9 W/m²K.

Guidance for specification option:

Lowest U-value achievable; consult manufacturer for project-specific values.

Frame

-

Material

Extruded aluminium.

Finish

-

Coating

Powder coating to BS EN 12206-1.

Colour

Anthracite Grey (RAL 7016).

Black (RAL 9005).

White (RAL 9010).

Bespoke RAL.

Guidance for specification option:

Insert requirements.

Film thickness (minimum)

Manufacturer's standard.

Glazing or infill

-

Type

Insulating glass units, standard.

Guidance for specification option:

Double glazed.

Insulating glass units, solar control.

Insulating glass units, privacy glass.

Insulating glass units, body tinted.

Insulating glass units, acoustic laminate.

Insulating glass units, coloured glass.

Insulating glass units, CUin advanced thermal performance.

Insulating glass units, low iron glass.

Colour

Clear.

Other.

Guidance for specification option:

Insert requirements.

Hundreds of options are possible through the use of Vanceva® coloured laminated interlayer(s); consult manufacturer for details.

Coating

Standard.

Guidance for specification option:

Double glazed.

Easy-clean coating (Ritec).

Operation

-

Type

Powered, electric, 24 V.

Control

Battery back-up control panel.

Guidance for specification option:

Standard.

Smoke, gas, wind and rain sensors.

Guidance for specification option:

Optional.

Break glass and override switches.

Guidance for specification option:

Optional.

Full integration to building fire management system.

Guidance for specification option:

Optional.

Accessories

None.

Standard blind under glass connected to base frame.

Standard blind under glass in lightwell.

Paint or sandblast borders.

Manifestation.

Guidance for specification option:

Artwork, company logo or other - insert requirements.

Emergency break glass unit.

External kerb 1 m² (1284 x 1344 mm).

External kerb 1.5 m² (1284 x 1884 mm).

Fireman’s override switch.

Integrate to BMS.

Modular timber kerb at 5° pitch.

Smoke detector.

Specialist AOV control unit, 230 V to 24 V transformer plus battery backup.

Snow load

640 N/m².

Wind load

750 N/m².

Outer pane

Heat soaked toughened glass.

Cavity space fill

16 mm argon filled with Swisspacer warm edge spacer, silicone bonded.

Inner pane

Laminated glass.

Heat soak tested toughened glass.

Sustainability data

Contains Red List materials

No

Country of material origin

France

Country of product manufacture

United Kingdom

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

0 kg CO₂ eq/kg

Recyclability

Aluminium and glass are highly recycled

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

95 %

BIM objects

BIM object icon

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Third party certifications

BRE Certificate

BRE Certificate

P110587-1000 Issue: 1

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Certificate 2023

DoP

DoP

EN 12101 DoP

Literature

Data Sheet AOV Smoke Vent

Data Sheet AOV Smoke Vent

Certificate EN 12101 Test

Certificate EN 12101 Test

Data Sheet Flatglass Access Rooflights

Data Sheet Flatglass Access Rooflights

Flatglass Brochure

Flatglass Brochure

Certificate ISO 9001 2023

Certificate ISO 9001 2023

Warranty Document

Warranty Document

Certificate Weathertightness Test report

Certificate Weathertightness Test report

Data Sheet Smokelite AOV

Data Sheet Smokelite AOV

DWG AOV 1.5m² Gfa long section view

DWG AOV 1.5m² Gfa long section view

DWG AOV 1.5m² Gfa plan view

DWG AOV 1.5m² Gfa plan view

DWG AOV 1.5m² Gfa span view

DWG AOV 1.5m² Gfa span view

DWG AOV 1m² Gfa long section

DWG AOV 1m² Gfa long section

DWG AOV 1m² Gfa Plan View

DWG AOV 1m² Gfa Plan View

DWG AOV 1m² Gfa Span View

DWG AOV 1m² Gfa Span View

Case studies

Private Residence, Totteridge

Private Residence, Totteridge

Similar products from Roofglaze Rooflights Ltd

Skyway 24v Electric Hinged Flatglass For Ventilation  - Glass Rooflight

Skyway 24v Electric Hinged Flatglass For Ventilation - Glass Rooflight

Skyway Electric Access Flatglass Rooflight

Skyway Electric Access Flatglass Rooflight

Skyway Fixed Flat Glass Rooflight With Wall Abutment(s) - Multi Pane

Skyway Fixed Flat Glass Rooflight With Wall Abutment(s) - Multi Pane

Skyway Fixed Flatglass Rooflight - Multi Pane

Skyway Fixed Flatglass Rooflight - Multi Pane

Skyway Fixed Flatglass Rooflight - Single Pane

Skyway Fixed Flatglass Rooflight - Single Pane

Skyway Fixed Flatglass Rooflight With Wall Abutment(s) - Single Pane

Skyway Fixed Flatglass Rooflight With Wall Abutment(s) - Single Pane

Skyway Fixed Protect+ Flatglass Rooflight

Skyway Fixed Protect+ Flatglass Rooflight

Skyway Fixed Walk On Flat Glass Rooflight With Wall Abutment(s) - Single Pane