NBS Source
I'm a manufacturer

RF50-FR Rainscreen System - 50 mm Fire Rated Hook-On cassette panel

Verified by manufacturer 4 months ago

Spanwall Facades Ltd Third party certifications:
  • BR 135

    BR 135

    Certificate type

  • CWCT Certificate

    CWCT Certificate

    Certificate type

  • EN 13501-1 (Efectis)

    EN 13501-1 (Efectis)

    Certificate type

  • R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

    R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

    Certificate type

Hidden fix metal cassette rainscreen system.

Jump to:
+44 (0)28 9081 5303 Website

Application

Suitable for new build and refurbishment projects.

Description

Developed to architects', specifiers' and contractors' demands for a precision-made product that can meet all the statutory structural, fire, thermal, acoustic, and weathering criteria, the product has achieved fire performance classification in accordance with BR 135 (3rd edition): 2013, as tested according to BS 8414-2:2020 and is suitable for use on high rise buildings.


Panels:

Factory-manufactured 50 mm deep metal cassette panels with baffled horizontal joints and double return folds to vertical edges with cut-out slots for concealed fixing. They are secured by concealed anti-lift screws.

Supports:

Extruded aluminium wall support brackets to create the insulation zone and ventilation gap to the rear of panels. Extruded aluminium vertical carrier support/drainage channel with colour-coded infill strip, EPDM gaskets, providing sealing and anti-rattle functions, and fully adjustable aluminium support hooks, secured by S/S M8 bolts and nyloc nuts.

General information

Color

Other

Finish

Powder-coated

Anodized

Material

Aluminium

Stainless steel

Zinc

Cor-Ten

Shape

Other

Rectangle

Square

Trapezoid

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

25 year

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

Thermal insulation

As per contract requirements.

Secondary support structure

Extruded aluminium wall support brackets. Extruded aluminium vertical carrier support / drainage channel with colour coded infill strip, EPDM baffle gaskets and fully adjustable aluminium support hooks, secured by S/S M8 bolts and nyloc nuts.

Guidance for specification option:

Extruded aluminium wall support brackets to create the insulation zone and ventilation gap to rear of panels.

Cladding panels

-

Material

Aluminium cassette panels; External facing material: 3mm Aluminium alloy 3013 H14.

Guidance for specification option:

Factory manufactured 50mm deep metal cassette panels with baffled horizontal joints and double return folds to vertical edges with cut out slots for concealed fixing. Secured by concealed anti-lift screw.

Panel joints

20 mm open shadow line/ baffle joints.

System accessories

Flashings and copings to be manufactured by EDM Spanwall Facades Ltd. from mill finished aluminium and polyester powder painted to the same specification as the rainscreen panels.

Supports

Reinforced concrete wall or steelwork by others.

Bearing width

140 mm (minimum).

Manufacturer guidance

(for brackets)

Pitch

90 degrees as per section drawings.

Tolerances

Length (mm): ± 2mm; Height (mm): ± 2mm; Out of square (mm): ± 2mm.

Finish and colour

Polyester powder coated from the Syntha Pulvin Plus range with a coating thickness of 60 microns. Marine specification, applied by an approved Syntha Pulvin painting contractor.

Guidance for specification option:

Insert colour requirement or refer to schedule.

Fasteners

Size and type to be determined by the rainscreen installer and agreed with the Structural Engineer. Number and location as determined by panel layout and calculations.

Profile

Flat.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

United Kingdom

Recyclability

Yes

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

100 %

Third party certifications

BR 135

BR 135

BS8414-2:2020

CWCT Certificate

CWCT Certificate

CWCT 20/113

EN 13501-1 (Efectis)

EN 13501-1 (Efectis)

Reaction to Fire Performance

R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041

REACTION TO FIRE TEST REPORT Nr EUI-20-FFK2-000374-REVISION 1

Literature

RF50-FR vertical details

RF50-FR vertical details

RF50- FR Rainscreen System Brochure

RF50- FR Rainscreen System Brochure

RF50-FR HORIZONTAL DETAIL

RF50-FR HORIZONTAL DETAIL

Case studies

Lagan Bridge

Lagan Bridge

RVH Maternity Hospital Belfast

RVH Maternity Hospital Belfast

Titanic Building Belfast

Titanic Building Belfast