NBS Source
List your products
PYROSEC®
Application

For internal or external screens. Applications include: commercial offices, escape corridors and stairwells, retail outlets, factories and hotels, universities and schools, high specification residential properties, hospitals/ healthcare, government buildings, airport terminals, museums, libraries and leisure. Vision panels are supplied in FD30, FD60 and FD90 timber doors.

Description

Fire integrity and insulation glass, suitable for use in timber screens, timber doors, steel screens, steel door sets and insulating glass units (IGU's). It can be laminated with 7.5 mm thick pane to one or both sides using a single polyvinyl butyral (PVB) interlayer.

Features and benefits:

  • 30–120 minutes' (E and EI) fire rating.
  • Supplied with a clear, Matelux® acid etched or sandblasted surface.
  • Can be laminated for physical attack resistance.
  • CE marked.
  • Technical characteristics and maximum size are dependent on glass type, fire resistance and thickness required; consult manufacturer's literature for information.

Applications:

For internal or external screens. Applications include: commercial offices, escape corridors and stairwells, retail outlets, factories and hotels, universities and schools, high specification residential properties, hospitals/ healthcare, government buildings, airport terminals, museums, libraries and leisure. Vision panels are supplied in FD30, FD60 and FD90 timber doors.

General information

Features

30–120 minutes' (E and EI) fire rating, supplied with a clear, Matelux® acid etched or sandblasted surface, can be laminated for physical attack resistance and CE marked

Material

Fire integrity and insulation glass. Steel or timber frame

Size

Maximum size dependent on glass type, fire resistance and thickness, consult manufacturer's literature for information

Uniclass 2015

Pr_25_71_33_88 Thermally toughened glass sheetsPrimary

CAWS

H10/10 Patent glazing

H10/115 Patent glazing

H11/110 Curtain walling

H13/115 Structural glass assembly

L10/510 Glazed wood screens

L10/550 Glazed metal screens

L10/56 Glazed screen system

L10/560 Glazed screen system

L20/20 Wood flush doors

L20/230 Wood flush doors

L20/25 Wood panelled doors

L20/250 Wood panelled doors

L20/280 Doors

L20/410 Wood doorsets

L20/420 Wood doorsets

L20/430 Wood doorsets

L20/480 Doorsets

L20/55 Doorsets

L30/20 Stairs

L30/270 Stairs

L30/30 Proprietary

L30/310 Proprietary

L30/50 Purpose-made balustrades

L30/55 Proprietary balustrades

L30/550 Purpose-made balustrades

L30/560 Proprietary balustrades

L40/210 Putty-fronted single-glazing

L40/230 Bead-fixed single-glazing

L40/250 Bead-fixed single-glazing

L40/260 Bead-fixed single-glazing

L40/310 Bead-fixed single-glazing

L40/330 Bead-fixed single-glazing

L40/350 Bead-fixed single-glazing

L40/371 Bead-fixed insulating glass units

L40/372 Bead-fixed insulating glass units

L40/380 Bead-fixed insulating glass units

L40/381 Bead-fixed insulating glass units

L40/40 Putty-fronted single-glazing

L40/410 Single-glazing into grooves

L40/430 Single-glazing into grooves

L40/450 Single-glazing into grooves

L40/470 Zipper gasket glazing

L40/490 Single-sided gasket glazing

L40/50 Bead-fixed single-glazing

L40/530 Internal tape glazing

L40/55 Bead-fixed insulating glass units

L40/57 Bead-fixed insulating glass units

L40/58 Bead-fixed insulating glass units

L40/90 Internal tape glazing

Specification data - Thermally toughened glass sheets

Product Reference

PYROSEC® - Door

For internal or external doors.

PYROSEC® - Screen

For internal or external screens.

PYROSEC® - IGU

For internal or external insulating glass units (IGU).

Third party accreditation

Building Regulations (E&W): Approved Document B

Standard

To BS 6206: 1981 and EN 12600: 2002, BS 6180: 2011 for barriers within buildings, BS 476 Part 22: 1987 and BS EN 1364-1: 1999 for non-loadbearing walls and BS EN 1634-1: 2014 for doors and BS EN 12600: 2002 – Class 1B1 and BS 6206: 1981

Thickness

Insert requirement, consult manufacturer's literature for information.

Pattern

None (clear)

Matelux® acid etched

Sandblasted surface

Coating

-

Type

None, Matelux® acid etched or sandblasted surface

Dependent on Pattern specified.

Performance requirements

-

Fire protection

Insert requirements; 30–120 minutes' (E and EI) fire rating.

Impact resistance

To BS 6206: 1981 and EN 12600: 2002

Worked finish

-

Method

None, Matelux® acid etched or sandblasted surface

Dependent on Pattern specified.

Standard product features

Colour:

Clear.

Features:

30–120 minutes' (E and EI) fire rating, supplied with a clear, Matelux® acid etched or sandblasted surface, can be laminated for physical attack resistance and CE marked.

Material:

Fire integrity and insulation glass. Steel or timber frame.

Size:

Maximum size dependent on glass type, fire resistance and thickness, consult manufacturer's literature for information.

Third party certifications
  • TRADA: Q-Mark
  • Certifire : Certificate: CF5155
Similar products from Promat UK