Application

Can be installed on to any type of wall construction.

Description

Proteus SR ACM Metal is a composite panel rainscreen system available in a wide range of materials and finishes including aluminium, zinc, stainless steel and copper.


Features and benefits:

  • A range of panel sizes and metal finishes available.
  • Each panel is supported by the Proteus system of aluminium carriers and ancillary components.
  • Fully tested and compliant with CWCT standards.
  • Tested to EN 13501-1 achieving A2-s1,d0 or A1 subject to metal finish.

General information

Material

Aluminium

Uniclass 2015

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems Enhanced data

System performance

Rainscreen cladding system design.

Thermal insulation

To suit U-value requirements.

Breather membrane

-

Material

If breather membrane required by insulation manufacturer, insert material.

-

Fasteners

If breather membrane required, insert fastener type.

-

Secondary support structure

Proteus extruded aluminium rail system with Standard Proteus SR® system secret fix hook brackets to rear of cladding panels, and continuous mullion section around all openings to support panel edges.

To suit project specific loads, spans and cladding zone depth. Contact manufacturer for standard drawings or request meeting with architectural advisor.

Cavity fire barriers

-

Horizontal

Horizontal Cavity Barriers by others.

As specified by a fire engineer.

Vertical

Vertical Cavity Barriers by others.

As specified by a fire engineer.

Cladding panels

-

Material

4.0 mm Alpolic™ A1.

4.0 mm Alpolic™ A2.

4.0 mm Alucobond® A2.

4.0 mm Larson® A2.

4.0 mm Vitrabond A2.

Panel joints

20 mm recessed closed joints to match panel face.

Other joint widths/types are possible, please consult manufacturer.

Reveals

Continuous closer panels at openings, where reveal are less than 175 mm deep.

Contact manufacturer for further information.

Samples required

None.

Finish samples.

System samples.

Mock-ups or prototypes.

If system requirements not fully explored and agreed prior to specifying. Identify scale and purpose of mock-up, e.g. to agree interface details with other trades, etc.

System accessories

Not required.

Louvres.

Louvred doors.

Secret doors.

Perforated screens.

Fins.

Other.

Execution

As per Proteus SR installation manual. 

-

System completion

Maintenance and replacement

Colour

Consult manufacturer and insert requirement.

-

Reaction to fire

To EN 13501-1:2007+A1:2009, class A2-s1,d0.

4mm Alpolic™, 3 mm Alucobond®, 4 mm Alucobond®, 4mm Larson®, 3 mm Vitrabond,  4 mm Vitrabond, 6 mm Vitrabond.

To EN 13501-1:2007+A1:2009, class A1.

4mm Alpolic™.

Similar products from Proteus Facades

Proteus CX System (Porcelain Ceramic Rainscreen Cladding System)

Proteus CX System (Porcelain Ceramic Rainscreen Cladding System)

Proteus GL (Glass Rainscreen Cladding System)

Proteus GL (Glass Rainscreen Cladding System)

Proteus HR System (Metal Rainscreen Cladding System)

Proteus HR System (Metal Rainscreen Cladding System)

Proteus SR Metal

Proteus SR Metal