Verified by manufacturer over a year ago
A two-layer, high-performance, SBS-modified bitumen, torch-on flat roofing system.
Suitable for direct application to non-combustible substrates only, such as concrete/ screed, or in overlay situations onto existing asphalt/ built-up roof (BUR) substrates. Specify Profiles T.A. System for combustible substrates such as plywood or OSB – consult manufacturer for details.
Two-layer system incorporating a range of styrene butadiene styrene (SBS)-modified elastomeric bitumen membranes and accessories.
Profiles Systems incorporate a ‘striped’ pattern. This advanced vapour release technology has been designed to dissipate moisture vapour that may be trapped in the roofing system. When this trapped moisture warms, it can form pressure pockets within the system. Low melt bitumen needs a minimal application of flame to activate its fast adhesive properties.
Application:
Suitable for direct application to non-combustible substrates only, such as concrete/ screed, or in overlay situations onto existing asphalt/ built-up roof (BUR) substrates. Specify Profiles T.A. System for combustible substrates such as plywood or OSB – consult manufacturer for details.
Uniclass | |
CAWS | J41/130 Built-up reinforced bitumen membrane cold deck roof covering |
Product Reference | Profiles XL Cold Deck System |
Primer | Icopal S.F. Bitumen PrimerGuidance for specification option: Solvent-free bituminous primer. Icopal Siplast Bitumen PrimerGuidance for specification option: Quick-drying primer for torch-applied membranes. |
Underlay | Profiles Vent XLGuidance for specification option: Torch-applied membrane with stripes on underside to provide partial bond. |
Top layer | Profiles XL |
Colour | Blue-greyBrownGreenNoxite |
Flashings and detail work | |
Underlay | Icopal T.A. Detailing UnderlayGuidance for specification option: Thermically-activated, self-adhesive membrane for combustible details. Profiles XL SandGuidance for specification option: 4 mm torch-applied membrane. |
Capsheet | FireSmart T,A. Detailing CapsheetGuidance for specification option: Thermically-activated capsheet for combustible details. Profiles XL MineralGuidance for specification option: Torch-applied capsheet. |
Accessories | NoneIcopal GRP Edge TrimsIcopal Roofgard Cable and Tube DuctIcopal Roofgard Cowled Telescopic VentIcopal Roofgard Lightning Conductor PadsIcopal Roofgard OutletIcopal Roofgard Parapet Outlet |
Product Options | Preparation: Consult Icopal Ltd for details of the preparation and priming of the intended roof structure and substrate, and for details of the requirements for preparation layers, venting layers, nailing layers and taping strips. System build-up: Consult Icopal Limited’s technical literature for details and guidance. Icopal Limited is also able to offer a design and specification service, and it is recommended that they are consulted early on in the design process. |
Profiles T.A. Cold Roofing System
Profiles XL FireSmart Plus System - Cold Roof / Heated / Full Bond - System Number 17
Profiles XL FireSmart Plus System - Cold Roof / Heated / Partial Bond - System Number 15
Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Full Bond - System Number 16
Profiles XL FireSmart Plus System - Cold Roof / Safe2Torch / Partial Bond - System Number 14
ThermoSolo Roofing System
Total Torch Inverted Cold Deck Roofing System