NBS Source
I'm a manufacturer

Profiles Solo Roofing System

Verified by manufacturer over a year ago

BMI Group UK Ltd

Single layer reinforced bitumen membrane warm deck roof covering.

Jump to:
+44 (0)1908 015760 Website

Description

Single layer torch-applied system of high performance elastomeric SBS-modified bitumen membrane. The product has special stripes on the underside to provide a partial bond and allow dispersion of trapped vapour. The system is used in conjunction with an underlay and capsheet to form fully bonded details. The product is suitable for both new and refurbished roofs. The Profiles Solo system should be installed by a member of Icopal’s IMA-approved contractor network only.

Elastotherm is a single layer torch-on mineral capsheet manufactured on a strong polyester reinforcement coated on both sides with SBS polymer modified bitumen. The underside is finished with a specially blended bitumen stripe pattern and finished with thermofusible film.

The stripe pattern provides vapour equalization from entrapped moisture in the substrate avoiding blistering. The upper surface is finished with slate granules providing a decorative appearance and UV resistance.

General information

Uniclass

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/115 Single-layer reinforced bitumen membrane warm deck roof covering

J41/135 Single-layer reinforced bitumen membrane cold deck roof covering

Specification data - Reinforced bitumen membrane warm roof covering systems

Product Reference

Profiles Solo Roofing System

Primer

Icopal Siplast Bitumen Primer

Guidance for specification option:

Quick drying bituminous primer.

Icopal S.A. Primer

Guidance for specification option:

Quick drying primer for use with self-adhesive membranes.

Vapour control layer

Not required

Profiles T.A. VCL - Stripes

Guidance for specification option:

Heat-activated self-adhesive bituminous vapour control layer.

Profiles Vapour-Vent XL

Guidance for specification option:

Torch-applied vapour control layer with stripes on upper surface (for non-combustible substrates).

Insulation

Thermazone Torch-on

Guidance for specification option:

For partially bonded layers.

Top layer/ Capsheet

Profiles Solo single-layer membrane

Guidance for specification option:

Torch-applied layer with partial bond strips on underside and mineral finish top.

Flashings and detail work

-

Underlay

Profiles XL Sand

Guidance for specification option:

Torch applied membrane.

Icopal T.A. Detailing Underlay

Guidance for specification option:

Thermically-activated, self-adhesive membrane for combustible details.

Capsheet

Profiles XL Mineral

Guidance for specification option:

Torch applied capsheet.

FireSmart T,A. Detailing Capsheet

Guidance for specification option:

Thermically-activated capsheet for combustible details.

Accessories

None

Icopal Roofgard Lightning Conductor Pads

Icopal Roofgard GRP Edge Trims

Icopal Roofgard Outlet

Icopal Roofgard Parapet Outlet

Icopal Roofgard Cowled Telescopic Vent

Icopal Roofgard Cable and Tube Duct

Product Options

Preparation:

Consult manufacturer for details of the preparation and priming of the intended roof structure and substrate and for details of the requirements for preparation layers, venting layers, nailing layers and taping strips.

System build-up:

Consult manufacturer's technical literature for details and guidance. Icopal Limited is also able to offer a design and specification service and it is recommended that they are consulted early in the design process.

Similar products from BMI Group UK Ltd

FireSmart TorchSafe M.A. Roofing System

Power Elastomeric 250 Sand

Profiles T.A. Warm Roofing System

Profiles T.A. Warm Roofing System

Profiles XL Firesmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / MW

Profiles XL Firesmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / MW

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / PIR - System Number 1

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / PIR - System Number 1

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / MW

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / MW

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / PIR - System Number 5

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / PIR - System Number 5

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / MW - System Number 4

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / MW - System Number 4

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / PIR - System Number 2

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / PIR - System Number 2

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Heated / MW - System Number 12

Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Heated / MW - System Number 12