NBS Source
I'm a manufacturer

Application

  • Decoration: Conventional applications; furniture, partitions and doors. Products based on Planibel Clearvision – such as painted, acid-etched and sandblasted glass – are suitable for design work.
  • Architecture: For use outdoors as a base glass in architectural applications; laminated (shop windows), double skin facades and coated glass. Even in very thick versions required for wind resistance, Clearvision maintains its first-rate transparency and neutrality.
  • Solar: Suitable for solar applications, photovoltaic solar panels, thermal panels and solar mirrors. It has a particularly high energy transmission and an excellent transmission in the sensitivity spectrums of solar panels, making Planibel Clearvision suitable for maximizing the efficiency of solar applications.

Description

Extra-clear, low-iron float glass.


Features and benefits:

  • Light transmission of 92% (4 mm thick): increases amount of light entering a building, resulting in increased well-being of building occupants.
  • High colour rendering index: Provide superior quality of light in a building and lets the colours of objects or nature seen through the glass appear bright and fresh. When backpainted (interior applications), colours are true and pure.
  • High level of energy transmission.
  • Low level of energy absorption.
  • Even when used in extra-thick version  for furniture or interior design (up to  19 mm), it remains perfectly neutral.

General information

Color

Clear

Material

Glass

Uniclass

Pr_25_71_33_02 Annealed glass sheetsPrimary
Pr_25_71_33_46 Laminated glass sheets
Pr_25_71_33_88 Thermally toughened glass sheets
Pr_25_71_33_37 Heat-strengthened glass sheets

CAWS

L40/380 Bead-fixed insulating glass units

L40/450 Single-glazing into grooves

H13/115 Structural glass assembly

L10/390 Proprietary windows

H10/10 Patent glazing

L10/31 PVC-U windows

L40/40 Putty-fronted single-glazing

L40/50 Bead-fixed single-glazing

L40/55 Bead-fixed insulating glass units

L40/57 Bead-fixed insulating glass units

L40/230 Bead-fixed single-glazing

L40/330 Bead-fixed single-glazing

L40/350 Bead-fixed single-glazing

L40/430 Single-glazing into grooves

H10/115 Patent glazing

L10/330 Aluminium windows

L10/20 Steel windows

L40/90 Internal tape glazing

L40/58 Bead-fixed insulating glass units

L40/260 Bead-fixed single-glazing

L40/371 Bead-fixed insulating glass units

L40/490 Single-sided gasket glazing

H11/110 Curtain walling

L10/350 PVC-U windows

L10/15 Wood windows

L10/25 Aluminium windows

L10/30 PVC-U windows

L40/250 Bead-fixed single-glazing

L40/310 Bead-fixed single-glazing

L40/370 Bead-fixed insulating glass units

L10/210 Wood windows

L10/580 Secondary glazing system

L40/530 Internal tape glazing

L10/10 Wood windows

L10/33 Proprietary windows

L40/210 Putty-fronted single-glazing

L40/372 Bead-fixed insulating glass units

L40/381 Bead-fixed insulating glass units

L40/410 Single-glazing into grooves

L10/310 Steel windows

L10/400 Composite windows

L40/470 Zipper gasket glazing

L10/58 Secondary glazing system

Specification data - Annealed glass sheets

General requirements

Glass generally.

Third-party certification

Cradle to Cradle Certified™ Bronze.

Composition

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Thickness

3 mm.

Guidance for specification option:

Standard thickness.

Colour rendering index: 100.

Purity: 0.1 (according to CIE 15:2004).

4 mm.

Guidance for specification option:

Standard thickness.

Colour rendering index: 100.

Purity: 0.1 (according to CIE 15:2004).

5 mm.

Guidance for specification option:

Standard thickness.

Colour rendering index: 100.

Purity: 0.1 (according to CIE 15:2004).

6 mm.

Guidance for specification option:

Standard thickness.

Colour rendering index: 100.

Purity: 0.1 (according to CIE 15:2004).

8 mm.

Guidance for specification option:

Standard thickness.

Colour rendering index: 100.

Purity: 0.2 (according to CIE 15:2004).

10 mm.

Guidance for specification option:

Standard thickness.

Colour rendering index: 100.

Purity: 0.2 (according to CIE 15:2004).

12 mm.

Guidance for specification option:

Standard thickness.

Colour rendering index: 99.

Purity: 0.2 (according to CIE 15:2004).

15 mm.

Guidance for specification option:

Non-standard thickness, by request only. Consult manufacturer for details.

19 mm.

Guidance for specification option:

Non-standard thickness, by request only. Consult manufacturer for details.

Body colour

Clear.

Pattern

Guidance for specification option:

Insert requirements where applicable or delete item.

Performance requirements

-

Fire performance

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Light

Transmittance: 91–92%.

Guidance for specification option:

Thickness ≤8 mm: 92%; ≥10 mm: 91%.

Thickness 3–8 mm: 92%; 10–12 mm: 91%.

Consult manufacturer for details of thicknesses >12 mm.


Calculated according to EN 410.

Solar control

Solar factor: 89–91%.

Guidance for specification option:

Thickness 3–6 mm: 91%; 8–10 mm: 90%; 12 mm: 89%.

Consult manufacturer for details of thicknesses >12 mm.


Calculated according to EN 410.

Total shading coefficient

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Sound attenuation

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Impact resistance

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Worked finish

-

Method

Not required.

Sandblasted.

Guidance for specification option:

Insert details including design requirements.

Etching.

Guidance for specification option:

Insert details including design requirements.

Applied detail

None.

Silk screen printing and enamelling.

Guidance for specification option:

Insert requirements.

Processing

Not required.

Cutting, straight.

Guidance for specification option:

Insert requirements.

Cutting, circular.

Guidance for specification option:

Insert requirements.

Edge grinding.

Guidance for specification option:

Insert requirements.

Grinding.

Guidance for specification option:

Insert requirements.

Show more

Manufacturer guidance

Consult manufacturer for further details.

Safety

Toughening/ heat strengthening.

Laminating (PVB).

Laminating (EVA).

Glazing units

Not required.

Double glazed IGUs.

Triple glazed IGUs.

Literature

Clearvision, low-iron glass by AGC

Clearvision, low-iron glass by AGC

Similar products from AGC Glass UK Ltd

Clearsight

Clearsight

Imagin

Imagin

Ipasol

Ipasol

Lacobel

Lacobel

Lacobel T

Lacobel T

Luxclear™

Luxclear™

Matelac

Matelac

Matelac T

Matelac T

Matelux

Matelux

Planibel Clearlite

Planibel Clearlite