BBA Agrément Certificate
Certificate type
QA Certificate
Certificate type
A polymer-based barrier external wall insulation system incorporating EPS 70E grade expanded polystyrene (EPS) insulation.
Dryvit’s Outsulation is a cost effective external wall insulation(EWI) suitable for use on either new construction or refurbishment projects. The system is based on a simple premise – insulation is more effective when placed on the exterior of a building. By bringing insulation to the outside of external walls, this barrier EWI eliminates thermal bridges; reduces air, wind and moisture penetration through the system; stabilises interior environments and minimises thermal shock.
Benefits:
Finish | FDPMR Acrylic textured finish. HDP Silicone based technology textured finish. PMRB Acrylic textured finish. |
Uniclass 2015 | |
CAWS | M21/20 External wall insulation system M21/210 External wall insulation system |
Product Reference | Outsulation® |
Insulation | - |
Method of fixing | Dryhesive™ PlusDryflexPolymer-based, water-resistant base coat and adhesive. |
Finish | FDPMRAcrylic textured finish. HDPSilicone based technology textured finish. PMRBAcrylic textured finish. |
Texture | FreestyleLymestoneQuarzputz 2 mm aggregateFDPMR, HDP and PMRB finishes. Sandblast 1 mm aggregatePMRB finish. Sandpebble 1.5 mm aggregateFDPMR, HDP and PMRB finishes. Sandpebble fine 1 mm aggregateHDP, FDPMR and PMRB finishes. |
Colour | Refer to standard colour range for details and insert requirements. |
Fire barrier | Not requiredMineral wool lamellaHigh performance mineral wool lamella for receiving Dryvit base coats and finishes. |
Accessories | Not requiredMouldingsExtensive range available, consult manufacturer for details. |
Standard product features | Insulation:
Reinforcement: Standard Plus – Glass Fibre. Panzer 20 and standard plus mesh to areas subject to high impact. Detailing mesh: Dryvit detail mesh suitable for back wrapping EWI at termination details, forming reveals, masking Fire barriers prior to placing general reinforcing mesh, forming groove details. Beads/ Trims: Dryvit Aluminium Starter Track to thickness of insulation mechanically fixed with suitable hammer head or self-tapping fixings to base of system. |
Product Options | Pretreatment: Consult with Dryvit for details of preparation to suit project substrate. Use fungicidal wash by system manufacturer. If required, specify in 'Structural substrate' clause. Insulation: Method of fixing: Dryhesive™ Plus adhesive and/ or mechanical fixings in accordance with manufacturer's recommendations. Finish:
Brick effect finish or other from speciality finish range are also available, consult with manufacturer for details. Accessories:
Fire barrier: Position fire barriers in accordance with Building Control Officers requirements. Barriers to be adhesively fixed with Dryvit Detail Mesh. |