NBS Source
List your products
Application

For use as wall panelling.

Description

Steel wall cladding panels with a mineral wool core, available in six external profile types.

Features and benefits:

  • Includes visible mounting.
  • Polyvinyl chloride (PVC) coating to the interior and exterior panels protects against solar radiation.
  • Provides fire protection.
  • CE marked.

Applications:

For use as wall panelling.

General information
Material

External and internal facing: 0.6 mm thick, coil-coated, hot-dip galvanized steel sheet, with a coating as specified and a PVC protective film

Core: Structural, web-oriented mineral fibre wool, securely attached to the sheet steel shell

Uniclass 2015
Carbon steel insulating sandwich panels (Pr_25_71_14_22)Primary
Specification data - Carbon steel insulating sandwich panels
Product Reference

Ostman Brucha WP-F Panel

Profile -
External -
Type

Profile 1

Standard, 50 mm pitch, 2 mm depth.

Profile 2

Special order, flat panel.

Profile 3

Special order, 122 mm pitch, 2 mm depth.

Profile 4

30 mm pitch, 2 mm depth.

Profile 5

61 mm pitch, 2 mm depth.

Profile 6

15 mm pitch, 2 mm depth.

External gauge

Standard, 0.6 mm

Special order

Smaller metal gauge, consult manufacturer for details.

Finish

25 μm thick polyester coating

Standard.

25 μm PVDF coating

50 μm PUR coating

Corten

Stainless steel

Internal -
Type

Profile 1

Standard, 50 mm pitch, 2 mm depth.

Profile 2

Special order, flat panel.

Profile 3

Special order, 122 mm pitch, 2 mm depth.

Gauge

Standard, 0.6 mm

Special order

Smaller metal gauge, consult manufacturer for details.

Size -
Width

1000 mm

Special order.

1100 mm

Standard.

Length

Insert requirement, available up to 15.6 m.

Core -
Density

120 kg/m³

Standard.

140 kg/m³

Core thickness

60 mm (WP-F60)

Thermal transmittance/ U-value (to BS EN 14509): 0.7 W/m²K; weight: 17.4 kg/m²; fire resistance: EI 30.

80 mm (WP-F80)

Thermal transmittance/ U-value (to BS EN 14509): 0.52 W/m²K; weight: 19.8 kg/m²; fire resistance: EI 60.

100 mm (WP-F100)

Thermal transmittance/ U-value (to BS EN 14509): 0.41 W/m²K; weight: 22.2 kg/m²; fire resistance: EI 90.

120 mm (WP-F120)

Thermal transmittance/ U-value (to BS EN 14509): 0.35 W/m²K; weight: 24.6 kg/m²; fire resistance: EI 120.

140 mm (WP-F140)

Thermal transmittance/ U-value (to BS EN 14509): 0.3 W/m²K; weight: 27 kg/m²; fire resistance: EI 120.

150 mm (WP-F150)

Thermal transmittance/ U-value (to BS EN 14509): 0.29 W/m²K; weight: 28.2 kg/m²; fire resistance: EI 180.

160 mm (WP-F160)

Thermal transmittance/ U-value (to BS EN 14509): 0.27 W/m²K; weight: 29.4 kg/m²; fire resistance: EI 180.

180 mm (WP-F180)

Thermal transmittance/ U-value (to BS EN 14509): 0.24 W/m²K; weight: 31.7 kg/m²; fire resistance: EI 180.

200 mm (WP-F200)

Thermal transmittance/ U-value (to BS EN 14509): 0.22 W/m²K; weight: 34.2 kg/m²; fire resistance: EI 240.

240 mm (WP-F240)

Thermal transmittance/ U-value (to BS EN 14509): 0.18 W/m²K; weight: 39 kg/m²; fire resistance: EI 240.

Colour

Insert requirement from the BASIC colour range, consult manufacturer's literature for information.

Standard product features

Material:

  • External and internal facing: 0.6 mm thick, coil-coated, hot-dip galvanized steel sheet, with a coating as specified and a PVC protective film.
  • Core: Structural, web-oriented mineral fibre wool, securely attached to the sheet steel shell.

Panel connection:

Tongue and groove system in which the panels interlink with no thermal bridge.

Technical characteristics:

  • Fire behaviour (to BS EN 13501-1): Euroclass A2-s1, d0, non-combustible.
  • Manufacturing tolerances: In accordance with BS EN 14509.
  • Sound insulation: 32 dB.

Third party certifications
  • FM Global : Approved
  • UL : Classified
  • LPCB: Certificate: 900a/b : Certified
Similar products from Ostman Thermal Ltd