QA Certificate
Certificate type
Steel roof cladding panels with a polyurethane core.
For use as roof panelling.
A drip cap should be fitted in the eave area to prevent a capillary effect (only possible on the construction site). Consult manufacturer for further details.
Steel roof cladding panels with a polyurethane core and trapezoidal profile. 3° minimum roof pitch (5.2%) without transverse joint and penetration.
Features and benefits:
Applications:
For use as roof panelling.
A drip cap should be fitted in the eave area to prevent a capillary effect (only possible on the construction site). Consult manufacturer for further details.
Material | External facing: 0.6 mm thick, coil-coated, hot-dip galvanized steel sheet, with a 25 μm thick polyester coating and a PVC protective film (if required) Internal facing: 0.5 mm thick, coil-coated, hot-dip galvanized steel sheet, with a 25 μm thick polyester coating Core: Polyurethane rigid foam manufactured in a continuously foamed process. Approximately 95% closed cells, securely attached to the steel sheet. No chlorofluorocarbons or halogenated chlorofluorocarbons due to the pentane foam process |
Uniclass 2015 | |
CAWS | H43/10 Metal insulating sandwich panel H43/120 Metal insulating sandwich panel |
Product Reference | Ostman Brucha DP Panel |
Profile | - |
Internal | - |
Type | Profile 1Standard, 50 mm pitch, 2 mm depth. Profile 2Special order, flat panel. Profile 3Special order, 122 mm pitch, 2 mm depth. |
Gauge | Standard, 0.5 mmSpecial orderSmaller metal gauge, consult manufacturer for details. |
External | - |
External gauge | Standard, 0.6 mmSpecial orderSmaller metal gauge, consult manufacturer for details. |
PVC protective film | Not requiredRequired |
Length | Insert requirement, available up to 21.5 m. |
Core thickness | 30 mm (DP 72)Thermal transmittance/ U-value (to BS EN 14509): 0.73 W/m²K; weight: 11.4 kg/m². 40 mm (DP 82)Thermal transmittance/ U-value (to BS EN 14509): 0.57 W/m²K; weight: 11.8 kg/m². 50 mm (DP 92)Special order. Thermal transmittance/ U-value (to BS EN 14509): 0.46 W/m²K; weight: 12.2 kg/m². 60 mm (DP 102)Thermal transmittance/ U-value (to BS EN 14509): 0.39 W/m²K; weight: 12.6 kg/m². 80 mm (DP 122)Thermal transmittance/ U-value (to BS EN 14509): 0.3 W/m²K; weight: 13.4 kg/m². 100 mm (DP 142)Thermal transmittance/ U-value (to BS EN 14509): 0.24 W/m²K; weight: 14.5 kg/m². 120 mm (DP 162)Thermal transmittance/ U-value (to BS EN 14509): 0.2 W/m²K; weight: 15.2 kg/m². 140 mm (DP 182)Thermal transmittance/ U-value (to BS EN 14509): 0.17 W/m²K; weight: 16 kg/m². 160 mm (DP 202)Thermal transmittance/ U-value (to BS EN 14509): 0.15 W/m²K; weight: 16.8 kg/m². |
Colour | Insert requirement from the BASIC colour range, consult manufacturer's literature for information. |
Notches | Not required60 mmStandard size for eaves. 100 mm120 mm150 mm200 mmStandard size for overlap. 300 mm |
Fire behaviour (to BS EN 13501-1) | Euroclass B-s1, d0Euroclass B-s2, d0Standard. |
Standard product features | Panel width: 1000 mm. Material:
External profile: 42 mm deep trapezoidal profile with a 333.3 mm pitch. Panel connection:
Technical characteristics:
|
© 2020 NBS Enterprises Ltd. All rights reserved.
1 / 1