NBS Source
I'm a manufacturer

Application

Application/ use:

  • To reinstate fire resistance through walls.
  • Where single and/or double plastic socket back boxes require fire resistance.
  • Where single and/or double plastic socket back boxes require improved acoustic performance.

Description

NS Putty Pads are a pre-cut system designed for easy application with single and double electrical sockets back boxes where fire resistance must be reinstated.

General information

Color

Green

Material

Guidance for specification option:

Fire Resistant Putty Pads.

Uniclass

Pr_30_31_68_42 Intumescent puttiesPrimary

CAWS

P12/350 Intumescent putty

Product range

Intumescent putties

Specification data - Intumescent putties

Material

Fire resistant putty pads.

Fire resistance

To BS EN 1366-3:2021.

Manufacturer guidance

BS EN 1366-3:2021 Fire resistance tests for service installations. Penetration seals See the approved FSi details for fire resistance performance.

Application temperature

+5°C to +35°C.

Guidance for specification option:

For unopened material, store in a well-ventilated, dry, cool environment. Recommended temp ranges +5°C - +35°C. Protect against exposure to direct sunlight. Always ensure that safe manual handling procedures are followed at all times.

Weight

~1.75 g/cm³.