Newton SP750 Cutter Sewage Pump
Application

Suitable for use on:

  • The removal of sewage and waste water from suitably manufactured sewage vessels;
  • Standard pumps supplied within Newton Trojan sewage lifting stations.

Can also be supplied as the pump option for Newton 1 m diameter sewage systems.

Description

A high quality sewage pump incorporating a tungsten carbide tipped cutting impeller that rotates against a serrated suction cover in order to cut solid waste before pumping, resulting in a much lower risk of blockage than similar sized vortex impeller pumps.

The SP750 Cutter has a cast iron base and stainless steel body, and is suitable for the removal of sewage and effluent waste within small to medium sized sewage chambers, and is especially suited for use within sewage lifting stations such as the Newton Trojan Pumping System - consult manufacturer for details.


Supplied in single phase (230 V 50 Hz) only, the product is available as both freestanding or for guide rail mounting when supplied with the optional auto-coupling set (1000 mm diameter chambers only). Switching options are also available with the SP750, which can be purchased with a fitted float switch for auto operation or without a float for control by a compatible Newton pump control panel. They are supplied with 10 metres of heavy duty rubber power cable.


Features and benefits:

  • Cutter impeller cuts through the waste, resulting in less blockages.
  • Provides protection against motor burnouts due to a locked impeller.
  • Double mechanical seals ensure increased durability against particle abrasion and wear.
  • High performance with low current and high efficiency.
  • Auto and manual versions are available.
  • Freestanding and guiderail mounted options.
  • Supplied with a one-year manufacturer’s warranty from the proven date of installation or the date of purchase. Three year warranty if serviced under a service contract.

System:

  • 63 mm pressure rated pipework and fittings.
  • Sewage panel single pump.
  • Sewage panel twin pump.


Power converter:

The Victron Inverter/ Charger units draw 12 V power from a single or a bank of 12 V batteries which is inverted into clean, pure sine wave, 230 V power to ensure that the Newton Pump continues to operate even during a power outage.


Control panel:

The panel features interface for use with Newton battery back-up and telemetry systems as well as connections to whole house alarm and monitoring systems. The control panel PCB is split with two separate circuits, ensuring that pumping will continue even if one of the control circuits should fail.

General information

Material

Size

225 x 190 x 445 mm

WarrantyDescription

Uniclass 2015

Pr_70_55_76_62 Private packaged pumping stationsPrimary

CAWS

R12/135 Private packaged pumping stations and pressure pipeline system

R18/310 Private packaged pumping stations

Specification data - Private packaged pumping stations Enhanced data

Pumps

-

Pump characteristic

Incorporates a tungsten carbide tipped cutting impeller that rotates against a serrated suction cover in order to cut solid waste before pumping, resulting in a much lower risk of blockage than similar sized vortex impeller pumps.

Control

The panel features interface for use with Newton battery back-up and telemetry systems as well as connections to whole house alarm and monitoring systems.

Integral accessories

Consult manufacturer and insert requirements.

Product Reference

SP750 Cutter Sewage Pump

P35, Automatic

230 V.

SP750 Cutter Sewage Pump P36, Manual

230 V.

Pump design

Cutter.

Recommended discharge pipe

63.

Max pumping head

13.0 m.

Max flow rate

440 L/minute.

Flow rate at 4 m head

360 L/minute.

Pump switching

Auto or by Control Panel.

Float switch

Pendant Sewage Float (auto only).

Pump start level

Adjustable.

Lowest or Stop Water Level

120 mm.

Weight manual/auto

19.90/ 20.10 kg.

Clean water pumping

No.

Effluent pumping

Yes.

Sewage pumping

Yes.

Fluid temperature range

0–40°C.

Power supply

Single Phase.

Motor output

750 W.

Amps (starting)

15.8.

Amps (running)

3.4.

Mechanical seals

Double carbon ceramic.

Pipework

63 mm pressure rated.

For sewage.

Battery back-up

Not required.

MultiPlus 12/3000.120 (BB3).

Battery back-up facility for pumps of SP750 Cutter.

Standby batteries

Northstar NSB 190FT (BB22).

High water level alarm

9 V battery (PA50).

Switch not suitable for regular contact with sewage.

Sewage Alarm CP5.

Alarm with sewage float.

Pump control

Newton Control Panel Pro (CP2).

Supplied with a vertical water level float switch and water high alarm float switch. Insert number of standby batteries required.

Newton Control Panel Pro and pre-fitted Newton Dialler (CP7).

Supplied with a vertical water level float switch and water high alarm float switch.

Newton Pump Controller (CP9).

Supplied with a vertical water level float switch and water high alarm float switch.

Sewage Control Panel.

Twin pump panel with alarm for sewage systems.

Literature