NBS Source
List your products
Newton 901-P
Application

Pre-priming of damp or porous concrete and screed prior to the application of Newton 902-P primer. Areas of application include:

  • Podium decks.
  • Car parks.
  • Warehousing and storage.
  • Garages.
  • Plant rooms.

Description

Two-part, solvent free, clear epoxy which is applied to damp and porous surfaces as a pre-primer prior to the application of Newton 902-P, a vapour barrier and primer for newly placed, or damp, concrete and screed.

The high quality epoxy formulation allows for application onto damp surfaces, whilst the low-viscosity penetrates deep into porous substrates to effectively seal the surface ready for the main primer application.

Newton 901-P is quick and simple to apply by brush, roller or squeegee, and can be applied over cementitious screeds and concrete just seven days after placement, and is a key component of the Newton NewSeal System for the sealing, coating and protection of exposed screed and concrete surfaces - consult manufacturer for further details.

Features and benefits:

  • Very damp-tolerable.
  • Can be applied to concrete and screed seven days after placement.
  • Low viscosity.
  • Solvent free.
  • Provides a good vapour barrier.
  • High-bond damp proof membrane (DPM) that provides a barrier to vapour and to prevent osmotic blistering.
  • Life expectancy is equal to that of the surface it is applied to.

Applications:

Pre-priming of damp or porous concrete and screed prior to the application of Newton 902-P primer. Areas of application include:

  • Podium decks.
  • Car parks.
  • Warehousing and storage.
  • Garages.
  • Plant rooms.

- Suitable substrates:

Indoor or outdoor floors of correctly formed, compacted and prepared:

  • Concrete, at least seven days old.
  • Screed, at least seven days old.

General information
Uniclass 2015
Pr_35_31_66_67 Primer-sealersPrimary
CAWS

C42/310 Repair mortar

J10/110 Proprietary mortar

J30/110 Cold applied tanking . . . . . .

J31/110 Cold deck roof coating

J31/120 Warm deck roof coating

J31/130 Inverted roof coating

J31/353 Waterproof coating

J40/290 High density polyethylene/ polypropylene studded cavity drain membrane

J40/295 Geocomposite studded cavity drainage/ venting membrane

J40/47 High density polyethylene/ polypropylene studded cavity drain membrane

Specification data - Primer-sealers
Product Reference

Newton 901-P

Standard product features

Form (two component):

Low viscosity epoxy resin.

Colour:

Clear.

Weight:

5.2 kg.

Technical characteristics:

- General:

  • Specific gravity: 1.05.
  • Application temperature: ≥5°C (substrate), 30°C (air).
  • Service temperature: -15 to +50°C.
  • Application rate: First coat: 0.25 kg/m². Second coat: 0.25 kg/m².
  • Odour: Ammonia smell when mixing.
  • Volatile organic compounds (VOC) content: <100 g/L.

- Drying:

  • Inter-coat adhesion window: At 8°C: 15–48 h; at 10°C: 13–40 h; at 15°C: 12–30 h; at 20°C: 11–28 h; at 25°C: 9–24 h.
  • To be kept free of light rain: At 8°C: 8 h; at 10°C: 8 h; at 15°C: 7 h; at 20°C: 6 h; at 25°C: 5 h.
  • To be kept free of heavy rain: At 8°C: 14 h; at 10°C: 12 h; at 15°C: 11 h; at 20°C: 10 h; at 25°C: 8 h.
  • Ready for temporary foot traffic: At 8°C: After 16 h; at 10°C: After 14 h; at 15°C: After 14 h; at 20°C: After 12 h; at 25°C: After 10 h.

- Cured membrane:

  • Membrane thickness: 0.18–0.23 mm.
  • Adhesion to concrete to BS EN 13892-8 (>B2.0): 3.5 MPa.
  • Water vapour transmission rate to EN 1504-2– UK Perm: >1.0 g/m²/24 hrs.
  • Water vapour diffusion resistance – Sd value: 2.066 m.
  • Water vapour diffusion resistance – μ value: 9391 μ.
  • Water vapour diffusion resistance: 10.331 MNs/g.
  • Reaction to fire classification: Euroclass F.