Verified by manufacturer 4 months ago
Bi-parting flap gate for public transport application.
Bi-parting flap gate offering high speed passenger flow through the use of flaps which retract into the cabinet when the passenger’s ticket is authorized. This type of gate offers unobstructed visibility for passengers and is silent and smooth in operation. It is designed with a compact stainless steel cabinet construction and special semi-rigid non-deforming impact absorbing flap panels, available as retractable single or telescopic flap panels.
Features and benefits:
Material | Steel Guidance for specification option:
|
Length | 1930 mm |
Height | 1072 mm |
Warranty description | Two year |
Uniclass | |
CAWS | L20/490 Automatic doors L20/60 Doors |
Housing | |
Material and finish | Stainless steel, Scotch Brite 4. |
Colour | Self-coloured. |
Panel | |
Rotation | Sliding. |
Material and finish | Metal core coated with energy absorbent integral polyurethane. |
Colour | Red. |
Size | |
Clear opening width (minimum) | 550 mm.900 mm. |
Height | 1072 mm. |
Control unit | Required.Guidance for specification option: Contactless. |
Power supply | 230 V a.c.Guidance for specification option: Standard. 50 Hz. 115 V a.c.Guidance for specification option: 60 Hz. |
Accessories | None.Heating system.Special order.Guidance for specification option: Insert requirements. |
Footprint | Rectangular. Tapered. |
Cabinet width | 300 mm. Guidance for specification option: Standard 200 mm. |
Flap panels | Single. Telescopic. |
Security | High-performance fraud detection. Guidance for specification option:
|
Traffic management systems | Top casework mounted LED display. Guidance for specification option: To show the passenger and/ or station staff:
|
Maintenance access unit | Access to ticket controller and gate management system via slide out end panels. Guidance for specification option: Mounted on heavy duty guide rails. Servicing does not impinge on adjacent passageways. Minimal removal parts to reduce mechanical failure and longevity or wear during servicing. |
Power failure | Moving panels can be configured to fail open. Manufacturer guidance
|
Ingress protection (IP) rating | IP43. |
Operating temperature | 0–45°C. Guidance for specification option: (at 95% relative humidity (RH) non-condensing). Down to -20°C with heating system. |
MeanTimeBetweenFailure | 12 million cycles. |
Passage rate | ≤60 passages per minute. |