KS1000 LP Insulated Roof Panel System PIR - Steel

Kingspan Insulated Panels Variant:

Kingspan Lo-Pitch Roof System is is designed to offer a architecturally striking, streamlined roofing solution.

Jump to:
+44 (0)1352 716100 www.kingspanpanels.co.uk

Application

Pitched roofs of 1.5° or more after deflection.

Description

Lo-Pitch (LP), secret-fix, shallow profiled, polyisocyanurate insulated roofing system with steel-faced panels and raised side joints.


Features and benefits:

  • Secret-fix appearance is created by elevated and capped fasteners clipped on site.
  • Panels are immune to attack from mould, fungi, mildew and vermin.
  • No urea-formaldehyde is used in the construction.
  • Panels are not deleterious.
  • An air leakage rate of 3 m³/hr/m² at 50 Pa or less can be achieved when the full building envelope is constructed using Kingspan panels.
  • Cover width: 1000 mm.


Approvals:

CE marked to BS EN 14509: 2013.


Fire:

  • Reaction to fire classification according to BS EN 13501–1:2007+A1:2009; B-s2,d0.
  • The panel is rated FAB when tested to BS 476 Part 3: 2004.

- FIREsafe system:

  • FM approval to FMRC 4880 and 4471 Class 1 fire classification, unlimited height, for roof applications.
  • Reaction to fire classification according to BS EN 13501-1:2007+A1:2009: B-s2,d0.
  • LPS 1181: 2014: Part 1: Issue 1.2, series of fire growth tests for LPCB approval and is certified to LPS 1181 Grade EXT-B.


Purlins, side rails and platforms supports:

Framed roof structure to be specified separately to include the following as required:

  • Multibeam purlins.
  • Multibeam eaves beams.
  • Cold-formed cleader angles.
  • Purlin cantilevers.
  • Cladding junctions.
  • Multichannel platform supports.
  • Multichannel trimmers.
  • Rafter stays (RNA/ RNB).


Warranties:

  • Maintenance and inspection free external coating: 40 years. Manufacturer’s external coating warranty to be available on project completion and be fully transferrable for future changes of building ownership.
  • Thermal performance: 25 years.
  • Structural performance: 25 years.

General information

Material

PIR

Steel

Shape

Rectangular

Size

1000 x 150 mm

WarrantyDescription

25/ 40 years

Warranties:

  • Maintenance and inspection free external coating: 40 years. Manufacturer’s external coating warranty to be available on project completion and be fully transferrable for future changes of building ownership.
  • Thermal performance: 25 years.
  • Structural performance: 25 years.

Uniclass 2015

Ss_30_40_55_54 Metal insulating sandwich panel roof systemsPrimary

CAWS

H43/10 Metal insulating sandwich panel

H43/120 Metal insulating sandwich panel

Specification data - Metal insulating sandwich panel roof systems Enhanced data

Roof pitch (degrees)

Insert requirement; minimum 1.5° or more after deflection.


Pitches below 4° will require the external sheet of the panel to be turned for weathering on site as follows:

  • At the eaves: Turned down, typically by 20°.
  • At the ridge: Turned up, typically by 45°.

-

Roofing panels

-

Panel type

Cover width: 1000 mm.

Single figure weighted sound reduction index (Rw): 25 dB.

ECOsafe and FIREsafe steel/PIR insulated sandwich panels, 0.18 W/m²K.

Core thickness: 115 mm; overall thickness: 150 mm.

Weight: 12.5 kg/m².

Panel fasteners

Insert requirements; Minimum two fasteners for each purlin position at sides of panel. Subject to wind loading; consult manufacturer's installation guide for details.


There may also be a requirement for applying a 4 mm-diameter butyl rubber sealant/ gun-grade vapour seal at the base of the side joint, dependent on project specification.


-

Side lap stitching fasteners

Manufacturer's standard.

Insert requirements (number/ location).

Snap-on cover caps; Stitching screw or sealed rivet at eaves or through capping end lap. Anti-condensation tape (factory applied) between panels.


At all ridge locations, gun grade sealant to be applied across the panel side joints in line with the profiled ridge filler location, to close off the cover cap end.

End lap stitching fasteners

38 mm-long tail stitching screws with 19 mm sealing washers.

Insert requirements (number/ location).

Five per panel, applied from centre outwards, ensuring stitching screws penetrate the factory fitted stitching plate.

Continuity thermal insulation

Profiled ridge filler.

Cavity barriers

Kingspan LPCB or FM Approved PIR board insulation to be installed in certain details to ensure thermal continuity.

Fill any gaps with fire-rated canister insulation.

Consult with manufacturer for further details.

Cavity closers

Kingspan LPCB or FM Approved PIR board insulation to be installed in certain details to ensure thermal continuity.

Fill any gaps with fire-rated canister insulation.

Consult with manufacturer for further details.

Fascia

-

Material

As roofing panel.

As design.

Insert requirements.

Support

Consult manufacturer and insert requirements.

Fasteners

Consult manufacturer and insert requirements.

Jointing

Consult manufacturer and insert requirements.

Soffit

-

Material

As roofing panel.

As design.

Insert requirements.

Support

Consult manufacturer and insert requirements.

Fasteners

Consult manufacturer and insert requirements.

Jointing

Consult manufacturer and insert requirements.

Gutters

-

Gutter types

Kingspan External Highline.

Kingspan Insulated Membrane Lined.

Support

Consult manufacturer and insert requirements.

Fasteners

Consult manufacturer and insert requirements.

Jointing

Consult manufacturer and insert requirements.

Accessories

Consult manufacturer and insert requirements.

System accessories

None.

Kingspan Energy - solar photovoltaics.

Rooftop Solar PV can be installed onto insulated roof panels - consult manufacturer for details.

Product Reference

KS1000 LP Insulated Roof Panel System - PIR, Steel

Design

Insert drawing reference or similar.


Length:

  • Standard lengths: 1.8–14.5 m, or insert drawing reference
  • Non-standard lengths of 14.5–29.3 m or <1.8 m are available on request; consult manufacturer for details.

Flashings

Required.

Insert requirements.

Rooflights

Kingspan Day-Lite Kapture.

Rooflights are to be specified fully separately - see Kingspan Light + Air or consult manufacturer for details.

Remove if not required.

Personal fall protection

Safeside.

To be specified separately. Remove if not required.

Digital objects

Platform Compatible Version Certified to
IFC
-

2

2.1
Revit
-

2

2.1
Download now from NBS National BIM Library

Similar products from Kingspan Insulated Panels

KS1000 CR Insulated Roof Panel System, PIR

KS1000 CR Insulated Roof Panel System, PIR

KS1000 SRW (PIR) Insulated Roofing System

KS1000 SRW (PIR) Insulated Roofing System

KS1000 Zip KingZip (PIR) Roofing System

KS1000 Zip KingZip (PIR) Roofing System

QuadCore KS1000RW Roof Panel System

QuadCore KS1000RW Roof Panel System

QuadCore™ Topdek Single Ply Membrane Roof Panel

QuadCore™ Topdek Single Ply Membrane Roof Panel