Weather-independent louvred ventilator.
Suitable for atria, shopping centres, industrial buildings, train stations and port applications.
Kingspan Eura-R is a multifunctional weather-independent louvred ventilator and designed to incorporate rainproof side louvres. The Eura-R is suitable for all-weather day-to-day ventilation as well as smoke and heat exhaust. During precipitation the building can be ventilated over the side louvres whilst top louvres remain closed. The structure has integrated rain gutters for controlled water drainage it can be customized with a variety of base and flange designs.
Suitable for all-weather day-to-day ventilation in combination with smoke and heat exhaust. The system has been tested and is certified in accordance with BS EN 12101-2 and is CE marked.
Features and benefits:
Applications:
Suitable for atria, shopping centres, industrial buildings, train stations and port applications.
Finish | AnodizedQualanod. Polyester powder coated, double layerInsert RAL colour requirement, 110 μ thick (Qualicoat). Polyester powder coated, single layerInsert RAL colour requirement, 60 μ thick (Qualicoat). UntreatedStandard. |
Material | Aluminium; tempered, sea water and corrosion-resistant (EN AW 5754). Corrosion-resistant bearings. Seal incorporating a weather-resistant sealing strip longitudinally and energy strips. The seal is applied in such a manner that there is no risk of freezing and offers a high level of draft-proof performance |
Uniclass 2015 |
Product Reference | Kingspan Eura-R Smoke and Heat Exhaust Ventilator with Weather-Independent Daily Ventilation |
Finish | AnodizedQualanod. Polyester powder coated, double layerInsert RAL colour requirement, 110 μ thick (Qualicoat). Polyester powder coated, single layerInsert RAL colour requirement, 60 μ thick (Qualicoat). UntreatedStandard. |
Louvre | - |
Material | AluAlu-isoIsolux 8/ 16 mmSandwich 16 mmSingle glass 3.3.2 |
Type | 060GHB and LB: 600 mm width; HB: 640 mm width. 120GHB and LB: 1200 mm width; HB: 1240 mm width. 180GHB and LB: 1800 mm width; HB: 1840 mm width. |
Quantity | 3GHB: 720 mm long ventilator; HB: 760 mm long ventilator; LB: 700 mm long ventilator. 4GHB: 940 mm long ventilator; HB: 980 mm long ventilator; LB: 920 mm long ventilator. 5GHB: 1160 mm long ventilator; HB: 1200 mm long ventilator; LB: 1140 mm long ventilator. 6GHB: 1380 mm long ventilator; HB: 1420 mm long ventilator; LB: 1360 mm long ventilator. 7GHB: 1600 mm long ventilator; HB: 1640 mm long ventilator; LB: 1580 mm long ventilator. 8GHB: 1820 mm long ventilator; HB: 1860 mm long ventilator; LB: 1800 mm long ventilator. 9GHB: 2040 mm long ventilator; HB: 2080 mm long ventilator; LB: 2020 mm long ventilator. 10GHB: 2260 mm long ventilator; HB: 2300 mm long ventilator; LB: 2240 mm long ventilator. 11GHB: 2480 mm long ventilator; HB: 2520 mm long ventilator; LB: 2460 mm long ventilator. 12GHB: 2700 mm long ventilator; HB: 2740 mm long ventilator; LB: 2680 mm long ventilator. 13GHB: 2920 mm long ventilator; HB: 2960 mm long ventilator; LB: 2900 mm long ventilator. 14GHB: 3140 mm long ventilator; HB: 3180 mm long ventilator; LB: 3120 mm long ventilator. 15GHB: 3360 mm long ventilator; HB: 3400 mm long ventilator; LB: 3340 mm long ventilator. 16GHB: 3580 mm long ventilator; HB: 3620 mm long ventilator; LB: 3560 mm long ventilator. 17GHB: 3800 mm long ventilator; HB: 3840 mm long ventilator; LB: 3780 mm long ventilator. |
Base | GHBInsulated high base. GHB with flange insulationInsulated high base. HBHigh base. LBLow base. |
Flanges | F1For single glass. F2For insulation glass. F3For upstand (folded edge 45°). F4Flat flange. F5For upstand (folded edge 90°). F6For corrugated sheet. F7Connection continuous rooflight. F8Coupling flange. |
Operation | - |
Top louvres | KCable operation. MMotor operation (24 V DC, 230 V AC). M24VMotor operation 24V (to BS EN 12101-2). PSingle-action compressed air operation. P2Double-action compressed air operation. P2BDouble-action compressed air operation with fire function (to BS EN 12101-2). PBSingle-action compressed air operation with fire function (to BS EN 12101-2). PB-10 barSingle-action compressed air operation with fire function activated at ≥10 bar (to BS EN 12101-2). PB-FSSingle-action compressed air operation with fire function failsafe (up to 13 louvres) (to BS EN 12101-2). PB-MSingle-action compressed air operation with fire function and motor operation (to BS EN 12101-2). |
Side louvres | KCable operation. MMotor operation (24 V DC, 230 V AC). PSingle-action compressed air operation. |
Accessories | Insert requirements, can be designed to incorporate noise-damping wings and bird or insect mesh as well as elevated side louvres for additional weather-independent ventilation. |
Standard product features | Material: Aluminium; tempered, sea water and corrosion-resistant (EN AW 5754). Corrosion-resistant bearings. Seal incorporating a weather-resistant sealing strip longitudinally and energy strips. The seal is applied in such a manner that there is no risk of freezing and offers a high level of draft-proof performance. Weight: Dependent on louvre type and quantity, consult manufacturer's literature for information. Aerodynamic surface: Dependent on louvre type and quantity, consult manufacturer's literature for information. |
Kingspan Ecofeu 110 SCE Stairwell Smoke Vent Combined with Roof Access
Kingspan Ecofeu Premium Alu 110 SCE Stairwell Smoke Vent Combined with Roof Access
Kingspan Eura Excellent Smoke and Heat Exhaust Ventilator
Kingspan Eura Smoke and Heat Exhaust Ventilator
Kingspan Optima Smoke and Heat Exhaust Ventilator - Thermally Broken