Suitable for atria, shopping centres, industrial buildings, train stations and port applications.

Description

Kingspan Eura-R is a multifunctional weather-independent louvred ventilator and designed to incorporate rainproof side louvres. The Eura-R is suitable for all-weather day-to-day ventilation as well as smoke and heat exhaust. During precipitation the building can be ventilated over the side louvres whilst top louvres remain closed. The structure has integrated rain gutters for controlled water drainage it can be customized with a variety of base and flange designs.

Suitable for all-weather day-to-day ventilation in combination with smoke and heat exhaust. The system has been tested and is certified in accordance with BS EN 12101-2 and is CE marked.

Features and benefits:

  • Multifunctional application (continuous rooflight, glass rooflight, shed constructions, directly on flat roof upstand).
  • Low energy consumption.
  • Optionally elevated side louvres for increased weather-independent ventilation.
  • Optionally designed to incorporate noise-damping wings and bird or insect mesh.
  • Optionally supplied in an anodized or powder-coated design (in any RAL colour).

Applications:

Suitable for atria, shopping centres, industrial buildings, train stations and port applications.

General information
Finish

Anodized

Qualanod.

Polyester powder coated, double layer

Insert RAL colour requirement, 110 μ thick (Qualicoat).

Polyester powder coated, single layer

Insert RAL colour requirement, 60 μ thick (Qualicoat).

Untreated

Standard.

Material

Aluminium; tempered, sea water and corrosion-resistant (EN AW 5754). Corrosion-resistant bearings. Seal incorporating a weather-resistant sealing strip longitudinally and energy strips. The seal is applied in such a manner that there is no risk of freezing and offers a high level of draft-proof performance

Uniclass 2015
Pr_70_65_04_56 Natural smoke and heat exhaust ventilatorsPrimary
Specification data - Natural smoke and heat exhaust ventilators
Product Reference

Kingspan Eura-R Smoke and Heat Exhaust Ventilator with Weather-Independent Daily Ventilation

Finish

Anodized

Qualanod.

Polyester powder coated, double layer

Insert RAL colour requirement, 110 μ thick (Qualicoat).

Polyester powder coated, single layer

Insert RAL colour requirement, 60 μ thick (Qualicoat).

Untreated

Standard.

Louvre -
Material

Alu

Alu-iso

Isolux 8/ 16 mm

Sandwich 16 mm

Single glass 3.3.2

Type

060

GHB and LB: 600 mm width; HB: 640 mm width.

120

GHB and LB: 1200 mm width; HB: 1240 mm width.

180

GHB and LB: 1800 mm width; HB: 1840 mm width.

Quantity

3

GHB: 720 mm long ventilator; HB: 760 mm long ventilator; LB: 700 mm long ventilator.

4

GHB: 940 mm long ventilator; HB: 980 mm long ventilator; LB: 920 mm long ventilator.

5

GHB: 1160 mm long ventilator; HB: 1200 mm long ventilator; LB: 1140 mm long ventilator.

6

GHB: 1380 mm long ventilator; HB: 1420 mm long ventilator; LB: 1360 mm long ventilator.

7

GHB: 1600 mm long ventilator; HB: 1640 mm long ventilator; LB: 1580 mm long ventilator.

8

GHB: 1820 mm long ventilator; HB: 1860 mm long ventilator; LB: 1800 mm long ventilator.

9

GHB: 2040 mm long ventilator; HB: 2080 mm long ventilator; LB: 2020 mm long ventilator.

10

GHB: 2260 mm long ventilator; HB: 2300 mm long ventilator; LB: 2240 mm long ventilator.

11

GHB: 2480 mm long ventilator; HB: 2520 mm long ventilator; LB: 2460 mm long ventilator.

12

GHB: 2700 mm long ventilator; HB: 2740 mm long ventilator; LB: 2680 mm long ventilator.

13

GHB: 2920 mm long ventilator; HB: 2960 mm long ventilator; LB: 2900 mm long ventilator.

14

GHB: 3140 mm long ventilator; HB: 3180 mm long ventilator; LB: 3120 mm long ventilator.

15

GHB: 3360 mm long ventilator; HB: 3400 mm long ventilator; LB: 3340 mm long ventilator.

16

GHB: 3580 mm long ventilator; HB: 3620 mm long ventilator; LB: 3560 mm long ventilator.

17

GHB: 3800 mm long ventilator; HB: 3840 mm long ventilator; LB: 3780 mm long ventilator.

Base

GHB

Insulated high base.

GHB with flange insulation

Insulated high base.

HB

High base.

LB

Low base.

Flanges

F1

For single glass.

F2

For insulation glass.

F3

For upstand (folded edge 45°).

F4

Flat flange.

F5

For upstand (folded edge 90°).

F6

For corrugated sheet.

F7

Connection continuous rooflight.

F8

Coupling flange.

Operation -
Top louvres

K

Cable operation.

M

Motor operation (24 V DC, 230 V AC).

M24V

Motor operation 24V (to BS EN 12101-2).

P

Single-action compressed air operation.

P2

Double-action compressed air operation.

P2B

Double-action compressed air operation with fire function (to BS EN 12101-2).

PB

Single-action compressed air operation with fire function (to BS EN 12101-2).

PB-10 bar

Single-action compressed air operation with fire function activated at ≥10 bar (to BS EN 12101-2).

PB-FS

Single-action compressed air operation with fire function failsafe (up to 13 louvres) (to BS EN 12101-2).

PB-M

Single-action compressed air operation with fire function and motor operation (to BS EN 12101-2).

Side louvres

K

Cable operation.

M

Motor operation (24 V DC, 230 V AC).

P

Single-action compressed air operation.

Accessories

Insert requirements, can be designed to incorporate noise-damping wings and bird or insect mesh as well as elevated side louvres for additional weather-independent ventilation.

Standard product features

Material:

Aluminium; tempered, sea water and corrosion-resistant (EN AW 5754). Corrosion-resistant bearings. Seal incorporating a weather-resistant sealing strip longitudinally and energy strips. The seal is applied in such a manner that there is no risk of freezing and offers a high level of draft-proof performance.

Weight:

Dependent on louvre type and quantity, consult manufacturer's literature for information.

Aerodynamic surface:

Dependent on louvre type and quantity, consult manufacturer's literature for information.