NBS Source
Kalzip Liner Roof System 0.15 U-Value

Kalzip Liner Roof System 0.15 U-Value

Kalzip Ltd Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Metal liner roof system, with a thermal transmittance (U-Value) of 0.15 W/m²K.

Jump to:
+44 (0)1942 295500 www.kalzip.com

Application

For roof applications.

Description

Metal liner roof system, with a thermal transmittance (U-Value) of 0.15 W/m²K. Suitable for use where speed of installation is required.

All work undertaken should be fully in accordance with Kalzip standard recommendations and by Kalzip approved welding contractors.


Site welding must be carried out fully in accordance with Approved Welding Procedure Specification ASW/TIG/001 Rev ‘B’ 1997 as defined in BS EN ISO 9606-2 for material gauges between 0.8–3 mm thickness. Site welding operatives must be certified to BS EN ISO 9606-2 standard for material gauges between 0.8–3 mm thickness. The weld test procedure shall be in accordance with BS EN ISO 15614-2: 2005.


Kalzip sheets to be installed as per cladding manufacturer's instructions.


Features and benefits:

  • The Kalzip liner roof system has the outer Kalzip standing seam roof sheet and the internal Kalzip liner trapezoidal profiled liner sheet laid in the same direction across roof purlins, acting as the primary support. Typical purlin centres would be approximately 1.4–1.8 m.
  • A non-fragile walkable Kalzip liner sheet can be quickly installed to provide a weather cover for those working below. The remainder of the roofing components can then be installed without affecting the critical path of the construction programme.
  • Suitable for a wide range of applications.

General information

Finish

Galvanized

Material

Aluminium

Steel

Mineral wool

Polyethylene

WarrantyDescription

Ten year

Uniclass

Ss_30_40_65_50 Metal profiled sheet self-supporting roof covering systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Specification data - Metal profiled sheet self-supporting roof covering systems Enhanced data

Liner sheets

-

Material

Galvanized steel to BS EN 10326.

Primary fasteners

5.5 mm diameter carbon steel self-drilling fasteners (SD-3-T15-5.5x25).

End and side laps

Side laps to be stitched at maximum 400 mm centres with 4.8 mm diameter carbon steel self-drilling stitching fasteners (SL2-T-4.8x20).

Air and vapour control layer

-

Material

Kalzip VCL Clear - Reinforced virgin polyethylene with 530 MNs/g vapour resistivity.

Sealing

Seal with one row of sealant tape, not less than 50 mm.

Spacers

Support clips, steel reinforced polyamide Kalzip E-clips type E.180.

Thermal insulation

Kalzip Insulation Quilt Type 2 - Manufactured with ECOSE™ Technology.

External sheets

-

Material

Aluminium Standing Seam 65/ 00.

Primary fasteners

6 mm diameter stainless steel torque controlled fasteners (SDK3-S-377-6.0x45).

System accessories

Not required.

Extruded aluminium alloy (EN AW-6061) gable end hooks.

Extruded aluminium alloy (EN AW-6063) drip angle 40 x 20 mm.

Extruded aluminium alloy (EN AW-6063) flat bar 22 x 6 mm.

Extruded aluminium alloy (EN AW-6063) gable end channel.

Extruded aluminium alloy (EN AW-6063) tolerance gable clip extrusion.

Fabricated aluminium alloy (EN AW-3004) flashings.

Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details.

Fabricated aluminium alloy (EN AW-3004) ridge closures (KZ 65/400).

Fabricated welded soaker units.

Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details.

Kalzip profile eaves fillers (KZ 65/400).

Kalzip profile ridge fillers (KZ 65/400).

Thermal transmittance (U-Value)

0.15 W/m²K.

Pitch

1.5° (minimum).

Bearing width

58 mm (minimum).

Type

Black closed cell cross-linked polyethylene with a minimum density of 30 kg/m³.

Thickness

30 mm (minimum).

Consult manufacturer and insert requirements.

Finish

Aluminium, AluPlusPatina.

Aluminium, natural stucco embossed.

Aluminium, with a PVDF paint coating.

Aluminium, with an HPC paint coating.

AluPlusZinc.

Show more

Thermal insulation

Mineral wool insulation, manufactured in accordance with BS EN 13162.

Shape

To suit project requirements.

-

Third-party certification

British Board of Agrément Certification No. 98/3481 and Institute fur Bautechnic Zulassungbescheid N R 14.1-181.

Environmental information

Contains Red List materials

No

Country of material origin

Germany

Embodied carbon

Refer to EPD certificate.

-

Recycled content

100 %

 Recycled aluminium top sheet.

Literature

Kalzip systems

Kalzip systems

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Kalzip 98/3481 Single Skin System Product Sheet 3

Similar products from Kalzip Ltd

Kalzip Acoustic Deck Roof System – 0.18 U-Value

Kalzip Acoustic Deck Roof System – 0.18 U-Value

Kalzip Acoustic Liner Roof Construction 0.18 U-Value

Kalzip Acoustic Liner Roof Construction 0.18 U-Value

Kalzip Deck Roof System 0.20 U-Value

Kalzip Deck Roof System 0.20 U-Value

Kalzip Liner Roof System 0.18 U-Value

Kalzip Liner Roof System 0.18 U-Value

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Structural Deck System

Kalzip Low U-Value Structural Deck System

Kalzip Standing Seam - Single Skin

Kalzip Standing Seam - Single Skin