Metal acoustic liner roof system, with a thermal transmittance (U-Value) of 0.18 W/m²K.

Jump to:
+44 (0)1942 295500 Website

Application

For roof and wall applications.

Description

Metal acoustic liner roof system, with a thermal transmittance (U-Value) of 0.18 W/m²K.


All work undertaken should be fully in accordance with Kalzip standard recommendations and by Kalzip approved welding contractors. Site welding must be carried out fully in accordance with Approved Welding Procedure Specification ASW/TIG/001 Rev ‘B’ 1997 as defined in BS EN ISO 9606-2 for material gauges between 0.8–3 mm thickness. Site welding operatives must be certified to BS EN ISO 9606-2 standard for material gauges between 0.8–3 mm thickness. The weld test procedure shall be in accordance with BS EN ISO 15614-2: 2005.


Kalzip sheets to be installed as per cladding manufacturer's instructions.


Features and benefits:

  • Perforated liner helps to improve the acoustic conditions within a building by helping to optimise reverberation times.
  • The Kalzip liner roof system has the outer Kalzip standing seam roof sheet and the internal Kalzip liner trapezoidal profiled liner sheet laid in the same direction across roof purlins, acting as the primary support. Typical purlin centres would be approximately 1.4–1.8 m.
  • A non-fragile walkable Kalzip liner sheet can be quickly installed to provide a weather cover for those working below. The remainder of the roofing components can then be installed without affecting the critical path of the construction programme.
  • Suitable for a wide range of applications.

General information

Color

-

Manufacturer guidance

Various options available to suit project requirements.

Finish

Galvanized

Guidance for specification option:

Various options to suit project parameters for further clarification speak to Kalzip

Material

Aluminium

Guidance for specification option:

Kalzip external sheet

Steel

Guidance for specification option:

Steel/aluminium internal sheet subject to project requirements

Shape

Other

Manufacturer guidance

Standing sheet profiles

Length

Bespoke

Width

-

Manufacturer guidance

Various cover widths available

Height

-

Manufacturer guidance

Kalzip seam height 65mm or 50mm

Warranty description

Ten year

Guidance for specification option:

Warranty period to suit project requirements

Manufacturer guidance

System warranties

Uniclass

Ss_30_40_65_50 Metal profiled sheet self-supporting roof covering systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Product range

Standing Seam

Specification data - Metal profiled sheet self-supporting roof covering systems

Liner sheets

-

Material

Galvanized steel to BS EN 10326.

End and side laps

Guidance for specification option:

100 mm (minimum). Consult manufacturer for details and insert requirements.

Air and vapour control layer

-

Material

Kalzip VCL Clear - Reinforced virgin polyethylene with 530 MNs/g vapour resistivity.

Sealing

Seal with one row of sealant tape, not less than 50 mm.

Spacers

Support clips, steel reinforced polyamide Kalzip E-clips type E.160 with S10 and S5 spacer.

Acoustic insulation

Kalzip Acoustic Rockfibre Slab (Tissue faced).

Guidance for specification option:

Manufactured with ECOSE™ Technology.

Thermal insulation

Kalzip Insulation Quilt Type 1.

Guidance for specification option:

Manufactured with ECOSE™ Technology.

External sheets

-

Material

Aluminium Standing Seam 65/400.

End and side laps

Mechanically seamed over head of support clips with a Kalzip 'zipping' machine.

System accessories

Not required.

Extruded aluminium alloy (EN AW-6061) gable end hooks.

Extruded aluminium alloy (EN AW-6063) drip angle 40 x 20 mm.

Extruded aluminium alloy (EN AW-6063) flat bar 22 x 6 mm.

Extruded aluminium alloy (EN AW-6063) gable end channel.

Extruded aluminium alloy (EN AW-6063) tolerance gable clip extrusion.

Fabricated aluminium alloy (EN AW-3004) flashings.

Guidance for specification option:

Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details.

Fabricated aluminium alloy (EN AW-3004) ridge closures (KZ 65/400).

Fabricated welded soaker units.

Guidance for specification option:

Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details.

Kalzip profile eaves fillers (KZ 65/400).

Kalzip profile ridge fillers (KZ 65/400).

Thermal transmittance (U-Value)

0.18 W/m²K.

Pitch

1.5° (minimum).

Bearing width

58 mm (minimum).

Structural support

Cold rolled steel purlins.

Type

Black closed cell cross-linked polyethylene with a minimum density of 30 kg/m³.

Thickness

Guidance for specification option:

30 mm minimum. Consult manufacturer and insert requirements.

Finish

Aluminium, AluPlusPatina.

Aluminium, natural stucco embossed.

Aluminium, with a PVDF paint coating.

Aluminium, with an HPC paint coating.

AluPlusZinc.

Show more

Thermal insulation

Mineral wool insulation, manufactured in accordance with BS EN 13162.

Third-party certification

British Board of Agrément Certification No. 98/3481 and Institute fur Bautechnic Zulassungbescheid N R 14.1-181.

Sustainability data

Contains Red List materials

No

Country of material origin

Germany

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

-

Manufacturer guidance

Refer to EPD certificate.

Recyclability

Excellent

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

100 %

Guidance for specification option:

 Recycled aluminium top sheet.

EPD

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Kalzip 98/3481 Liner Roof System Product Sheet 1

BBA Agrément Certificate

BBA Agrément Certificate

Kalzip BBA 98 3481 Deck Roof System Product Sheet 2

ISO 14001 Environmental Management Systems

ISO 14001 Environmental Management Systems

Kalzip ISO 14001

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

Kalzip ISO 45001

ISO 9001 Quality Management

ISO 9001 Quality Management

Kalzip ISO 9001

EPD

EPD

Kalzip Standing Seam EPD

European Technical Approval (ETA)

European Technical Approval (ETA)

Kalzip ETA

Literature

Kalzip systems

Kalzip systems

Case studies

Kelvin Hall, Glasgow

Kelvin Hall, Glasgow

South Bristol Skills Academy

South Bristol Skills Academy

SSE Hydro Arena, Glasgow

SSE Hydro Arena, Glasgow

Similar products from Kalzip Ltd

Kalzip Acoustic Deck Roof System

Kalzip Acoustic Deck Roof System

Kalzip Deck Roof System 0.20 U-Value

Kalzip Deck Roof System 0.20 U-Value

Kalzip Liner Deck Roof System 0.15 U-Value

Kalzip Liner Deck Roof System 0.15 U-Value

Kalzip Liner Roof System

Kalzip Liner Roof System

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Roof System 0.09 W/m²K

Kalzip Low U-Value Structural Deck System - Aluminium standing seam system

Kalzip Low U-Value Structural Deck System - Aluminium standing seam system

Kalzip Standing Seam - Single Skin - Aluminium standing seam profiles.

Kalzip Standing Seam - Single Skin - Aluminium standing seam profiles.