A range of chain actuators, suitable for façade and roof windows.

Features and benefits:

  • Can be used for windows and vents for smoke exhaust; D+H Euro SHEV in accordance with EN 12101-2 and for daily ventilation.
  • With motor electronics controlled via microprocessor or with integrated BSY+ motor and synchronised electronics controlled via microprocessor.
  • High-speed function (HS) for especially fast opening windows in case of fire (SHEV).
  • Two drive chains for optimal power application to the sash and electronic force and position control (KA 66-TW only).
  • Special chain stabilization.
  • Pressure applications up to 700 mm, application tension up to 300 mm stroke.
  • Relief of pressure on window gasket after closing process.
  • Programmable drive functions and different drive parameters.
  • Running speed in closed direction decreases to 5 mm/s (passive closing edge protection).
  • Time-controlled reversing when an obstacle is detected in the closed direction (active closing edge protection).

General information
Specification data
Product Reference

KA Chain Actuator

Type

See 'Options' below and insert reference.

Accessories

None

Brackets

Various options available consult literature and insert product reference(s).

Cables

Standard product features

Technical characteristics:

  • Supply: 24 V d.c (1 A). Except for '- K' drives which requires 230 V (50 Hz).
  • Duty cycle: 30%.
  • Force of pressure: 300, 500 or 600 N. (Twin).
  • Tensile force: 300, 500 or 600 N. (Twin).
  • Nominal locking force: 2000 or 3000 N.
  • Service life: > 10 000 double strokes.
  • Open running speed: 11.8 mm/s. (Except KA 34-K: 12.2 mm/s and KA 54 -K: 13.3 mm/s).
  • Open running speed - SHEV: 12.2 or 13.3 mm/s. (Not KA 34-K and 54-K drives).
  • Closed running speed: 11.8 mm/s.
  • Ingress protection rating: IP 32.
  • Fire resistance: B300 (30 min/ 300°C).
  • Housing: Aluminium.
  • Surface: Powder coated white aluminium (~RAL 9006).
  • Connection: 2.5 m cable.
  • Standards: EN 12101-2 CE certified, VdS G 503007 and TUV SUD B 08 11 22802 026. (Not applicable to all models, refer to technical literature for details).

Product Options

Type:

- KA 34 drive:

  • KA 34/350. Stroke: 350 mm.
  • KA 34/500. Stroke: 500 mm.
  • KA 34/600. Stroke: 600 mm.
  • KA 34/700. Stroke: 700 mm.
  • KA 34/800. Stroke: 800 mm.
  • KA 34/1000. Stroke: 1000 mm.
  • KA 34/1000. Stroke: 1200 mm.
  • KA 34/1000. Stroke: 1300 mm.
  • KA-PLP. Variable equipment possible.

- KA 34-BSY+ Set (2 synchronised drives):

  • KA 34/350-BSY+ Set. Stroke: 350 mm. Standard + '-L' drive.
  • KA 34/500-BSY+ Set. Stroke: 500 mm. Standard + '-L' drive.
  • KA 34/600-BSY+ Set. Stroke: 600 mm. Standard + '-L' drive.
  • KA 34/700-BSY+ Set. Stroke: 700 mm. Standard + '-L' drive.
  • KA 34/800-BSY+ Set. Stroke: 800 mm. Standard + '-L' drive.
  • KA 34/1000-BSY+ Set. Stroke: 1000 mm. Standard + '-L' drive.
  • KA 34/1200-BSY+ Set. Stroke: 1200 mm. Standard + '-L' drive.
  • KA 34/1300-BSY+ Set. Stroke: 1300 mm. Standard + '-L' drive.
  • KA-BSY+. Variable equipment possible.

- KA 34-K drive (direct control via 230 V):

  • KA 34/350-K. Stroke: 350 mm.
  • KA 34/500-K. Stroke: 500 mm.
  • KA 34/600-K. Stroke: 600 mm.
  • KA 34/700-K. Stroke: 700 mm.
  • KA 34/800-K. Stroke: 800 mm.
  • KA 34/1000-K. Stroke: 1000 mm,.
  • KA 34/1200-K. Stroke: 1200 mm.
  • KA 34/1300-K. Stroke: 1300 mm.
  • KA-K. Variable equipment possible.

- KA 54 drive:

  • KA 54/350. Stroke: 350 mm.
  • KA 54/500. Stroke: 500 mm.
  • KA 54/600. Stroke: 600 mm.
  • KA 54/700. Stroke: 700 mm.
  • KA 54/800. Stroke: 800 mm.
  • KA 54/1000. Stroke: 1000 mm.
  • KA 54/1200. Stroke: 1200 mm.
  • KA 54/1300. Stroke: 1300 mm.
  • KA-PLP. Variable equipment possible.

- KA 54-BSY+ Set (2 synchronised drives):

  • KA 54/350-BSY+ Set. Stroke: 350 mm. Standard + '-L' drive.
  • KA 54/500-BSY+ Set. Stroke: 500 mm. Standard + '-L' drive.
  • KA 54/600-BSY+ Set. Stroke: 600 mm. Standard + '-L' drive.
  • KA 54/700-BSY+ Set. Stroke: 700 mm. Standard + '-L' drive.
  • KA 54/800-BSY+ Set. Stroke: 800 mm. Standard + '-L' drive.
  • KA 54/1000-BSY+ Set. Stroke: 1000 mm. Standard + '-L' drive.
  • KA 54/1200-BSY+ Set. Stroke: 1200 mm. Standard + '-L' drive.
  • KA 54/1300-BSY+ Set. Stroke: 1300 mm. Standard + '-L' drive.
  • KA-BSY+. Variable equipment possible.

- KA 54-K drive (direct control via 230 V):

  • KA 54/350-K. Stroke: 350 mm.
  • KA 54/500-K. Stroke: 500 mm.
  • KA 54/600-K. Stroke: 600 mm.
  • KA 54/700-K. Stroke: 700 mm.
  • KA 54/800-K. Stroke: 800 mm.
  • KA 54/1000-K. Stroke: 1000 mm.
  • KA 54/1200-K. Stroke: 1200 mm.
  • KA 54/1300-K. Stroke: 1300 mm.
  • KA-K. Variable equipment possible.

- KA 66-TW drive (Twin drive):

  • KA 66/500-TW065. Stroke: 500 mm.
  • KA 66/350-TW1. Stroke: 350 mm.
  • KA 66/500-TW1. Stroke: 500 mm.
  • KA 66/600-TW1. Stroke: 600 mm.
  • KA 66/800-TW1. Stroke: 800 mm.
  • KA-TW-BSY+. Variable equipment possible.

- KA 66-TW-K Twin drive (direct control via 230 V):

  • KA 66/500-TW065-K. Stroke: 500 mm.
  • KA 66/350-TW1-K. Stroke: 350 mm.
  • KA 66/500-TW1-K. Stroke: 500 mm.
  • KA 66/600-TW1-K. Stroke: 600 mm.
  • KA 66/800-TW1-K. Stroke: 800 mm.
  • KA-TW-BSY+ -K. Variable equipment possible.

For windows, ventilation flaps and skylights, centred chain outlet and electronic closing force optimization. Option of integrating external rain detectors and room temperature controllers and additional passive and active anti-trap protection system for the main closing edges.