Unobtrusive ventilation to top edge abutments of lean-to roofs.

Jump to:
+44 (0)161 905 5700 Website

Application

MR50 Monovent is recommended be used in conjunction with Glidevale eaves ventilation systems to ensure through ventilation of the roof space from low to high level. When used with Type LR underlays such as Protect VP400 Plus LR it can also be used on its own to provide the ventilation requirement. Suitable for installation under dormer window sills when insulation is at rafter level.


Description

MR50 Monovent provides unobtrusive ventilation to top edge abutments of lean-to roofs. The innovative design ensures a continuous ventilation gap of 5000 mm²/m.


Features and benefits:

  • Guaranteed 5000 mm²/m ventilation provision to comply with BS 5250 and Building Regulations.
  • Deluge and driving rain resistant as well as preventing large insect ingress.
  • Unobtrusive when installed. Hidden within the roof flashings.
  • Available with integral AluFlash, the lead-free alternative.
  • Each unit overlaps the next to ensure integrity of flashing.
  • Quick and easy to install. 
  • Minimum pitch 15°

General information

Color

Black

Finish

Smooth

Material

Polyvinyl chloride (PVC)

Length

1220 mm

Width

30.5 mm

Height

171.5 mm

Uniclass

Pr_30_59_29_02 Abutment ventilatorsPrimary

CAWS

H60/47 Eaves

H65/355 Ventilated eaves – separated grilles/ trays

H62/355 Ventilated eaves with separated grilles/ trays

H60/355 Ventilated eaves with separated grilles/ trays

H61/355 Ventilated eaves with separated grilles/ rays

H65/80 Dry ventilated mono-ridges

Specification data - Abutment ventilators

Purpose

Unobtrusive ventilation to top edge abutments of lean-to roofs.

Ventilation opening

5000 mm²/m.

Colour

Black.

Length

1.22 m.

Sustainability data

Country of product manufacture

United Kingdom

BIM objects

Platform Compatible Version
Revit
-

1

Literature

Glidevale Protect Abutment Ventilation Systems

Glidevale Protect Abutment Ventilation Systems

BS 5250:2021 Management of moisture in buildings

BS 5250:2021 Management of moisture in buildings

Similar products from BPD Building Product Design Ltd

Glidevale Protect AV50 Abutment Vent - Abutment vent

Glidevale Protect AV50 Abutment Vent - Abutment vent