Glidevale Protect Barriair VCL
Application

Suitable for timber frame, pre-cast concrete and traditional brick and block construction. Can be used on walls and ceilings to significantly reduce air leakage in any construction.

Description

Protect BarriAir with integrated lap and sealing tapes is a high performance and multi-purpose coated non-woven membrane which forms a highly effective air leakage barrier with vapour control qualities.


Features and benefits:

  • Suitable for timber frame, pre-cast concrete and traditional brick and block construction.
  • Provides an airtight system when installed with sealed laps.
  • Dramatically reduces heat loss through the building fabric.
  • Improves the thermal performance of all insulants by reducing convection flows.
  • Tough, durable with high tear resistance.
  • Provides support to mineral wool and rock fibre when fixed to timber frame studs or rafters.
  • Helps to avoid interstitial condensation risk within insulation in accordance with BS 5250.
  • Separate Protect sealing tapes also available.
  • Ideal for Passivhaus projects.
  • Easy to cut and lightweight to handle in 1.5 x 50 m rolls.
  • 3 m wide option, without integrated tape, ideal for factory fitting.

General information

Finish

Semi-translucent

Color

Yellow

Material

Polypropylene

Coated non-woven membrane twin ply construction.

Shape

Roll

Size

1.5 x 50 m

With integrated tape.

3.0 x 50 m

No integrated tape.

Uniclass 2015

Pr_25_57_10_94 Vapour permeable sheetsPrimary

CAWS

P10/310 Air and vapour control layer

J21/395 Air and vapour control layer

J41/395 Air and vapour control layer

H92/780 Air and vapour control layer

H11/785 Air and vapour control layer

J42/395 Air and vapour control layer

H92/450 Air and Vapour control layer

H30/30 Air and vapour control membrane

H31/261 Air and vapour control membrane

H31/45 Air and vapour control membrane

H30/261 Air and vapour control membrane

Specification data - Vapour permeable sheets Enhanced data

Standard

BS 5250.

BS EN 1931.

Class (minimum)

W1.

Material

Non-woven polypropylene.

Of twin ply construction.

Form

Non-woven.

Weight (minimum)

100 g/m².

Thickness (minimum)

0.5 mm.

Reflective face

No.

Execution

Installed on the warm side of the structure immediately adjacent to the insulation.

Product Reference

Glidevale Protect Barriair VCL

Tear strength

197 (N).

MD (along roll) - (N) to EN 12310-1 with mods.

208 (N).

CD (across roll) - (N) to EN 12310-1 with mods.

TensileStrength

193 (N/50 mm).

MD (along roll) - (N/50mm) to EN 12311 with mods.

184 (N/50 mm).

CD (across roll) - (N/50mm) to EN 12311 with mods.

Air permeability

0.0 L/m²/s.

At 200 Pa.

Water vapour resistance

95 MNs/g.

To EN 1931.

Environmental information

Contains Red List materials

No

Country of product manufacture

United Kingdom

Recycled content

Recycled materials will vary.

-
Case Studies