A passivhaus certified mullion and transom glass roof system for atrium rooflight solutions with optional ventilation.

Jump to:
+443301227638 Website

Application

Suitable for energy-efficient commercial glass roof applications.


Description

The LAMILUX Glass Roof PR60 Passivhaus features virtually free shaping for atrium glass roof designs from pitches as low as 3° - making it possible to implement more or less any aesthetically pleasing and technically complex daylight construction. With trademark features including an attractive design, coupled with PHA certification to certify the highest level of airtightness and heat-insulation values, the PR60 passivhaus boasts exceptionally watertight properties, which guarantees no leaks in extremely high winds & driving rain, and effective soundproofing, which reduces the impact of unwanted noise to the interior.


Features and benefits:

  • Independently tested & certified by The Passive House Institute in Darmstadt as a phA Advanced Component – the highest possible efficiency class with easy PHPP calculations, as our product data is pre-loaded into the PHPP software.
  • Flexible shaping to suit individual project needs.
  • The system can be pitched down to as low as 3°
  • Large spanning system which can self-span up to six metres - removing the need for any intermediate steel purlins or support framework.
  • Watertight tested against wind driven rain down to 3° slope with a watertight test result of class RE 1950. This means that right down to the shallowest pitch it will remain completely watertight.

General information

Color

-

Manufacturer guidance

Available in any RAL colour.

Material

Glass

Aluminium

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

H11/110 Curtain walling

L10/45 Rooflights

H10/10 Patent glazing

H10/115 Patent glazing

L10/460 Rooflights

Product range

Glass rooflights

Specification data - Framed rooflights

Form

Flat.

Size

As drawing.

Product performance

-

Fire performance

-

Fire resistance

To EN 13830:2003.

Whole window U-value

Guidance for specification option:

PHPP calculations pre-loaded into the PHPP software.

Frame

-

Material

Aluminium.

Finish

-

Coating

PPC coated.

Colour

Guidance for specification option:

Can be powder coated to any RAL colour. Insert requirements. 

Glazing or infill

-

Type

Clear toughened outer and clear laminated safety glass inner.

Guidance for specification option:

Gas filled cavity and spacer as required to achieve performance required.


Add any specialist glazing requirements here (i.e. solar control glazing). Ug (glass) = 0.7 W/m²K in the vertical orientation.

Construction

Triple skin.

Colour

Clear.

Coating

Low E coating.

Operation

-

Type

Fixed (non opening).

Accessories

None.

Controllable sun protection with exterior blind.

Manufacturer guidance

Non-standard options are available on request.

Resistance to wind load

Stability against maximum wind load 2 KN/m² to EN 13830:2003.

Watertightness

To EN 13830:2003, RE 1950 rating.

Guidance for specification option:

Watertight under driving rain.

Air permeability

AE 1950. Assembly airtight (including vents) to EN 13830:2003.

Sound insulation

Guidance for specification option:

Varies upon glazing specification. Contact manufacturer for data sheet. 

Light transmission

Guidance for specification option:

Varies upon glazing specification. Contact manufacturer for data sheet. 

SolarTransmittance

Guidance for specification option:

Varies upon glazing specification. Contact manufacturer for data sheet. 

Pitch

As drawing.

Guidance for specification option:

The system can be pitched down to as low as 3°.

Upstand

Complete roof light assembly designed to sit on to pre-weathered perimeter sub-structure (by others).

Guidance for specification option:

Which is to be designed to suit the roof glazing system fixing and loadings requirements.  

Third-party certification

pha Advanced Component.

Sustainability data

Contains Red List materials

No

Country of product manufacture

Germany

EPD

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

EPD

EPD

EDP - Barrel Vault Rooflight

TUV - Safety and Quality Report

TUV - Safety and Quality Report

ISO 50001:2011

TUV - Safety and Quality Report

TUV - Safety and Quality Report

ISO 9001 : 2015

Literature

LAMILUX Passivhaus Brochure

LAMILUX Passivhaus Brochure

LAMILUX Glass Roof Brochure

LAMILUX Glass Roof Brochure

LAMILUX Roofs of Light Brochure

LAMILUX Roofs of Light Brochure

Case studies

University of Leicester - atrium glass rooflight

University of Leicester - atrium glass rooflight

Similar products from Lamilux Rooflights Ltd

Continuous Barrel Vault Rooflight B

Continuous Barrel Vault Rooflight B

Glass Roof PR60 - Rooflight / Glass Atrium

Glass Roof PR60 - Rooflight / Glass Atrium

Glass Skylight F100 - rooflight

Glass Skylight F100 - rooflight

Glass Skylight F100 Circular - rooflight

Glass Skylight F100 Circular - rooflight

Glass Skylight FE 3°  - Rooflight

Glass Skylight FE 3° - Rooflight

Glass Skylight FE Circular - rooflight

Glass Skylight FE Circular - rooflight

Glass Skylight FE Passivhaus - Rooflight

Glass Skylight FE Passivhaus - Rooflight

Glass Skylight Pyramid / Hipped  - rooflight - Rooflight / Skylight

Glass Skylight Pyramid / Hipped - rooflight - Rooflight / Skylight

Modular Glass Skylight MS78

Modular Glass Skylight MS78

Rooflight F100 Circular  - Skylight

Rooflight F100 Circular - Skylight