NBS Source
List your products
Description

A non-loadbearing wall system which provides up to 240 minutes fire resistance. It is used in certain retail and industrial storage areas to provide sub-division, and in other specific conditions of use as determined by insurance companies.

The wall comprises FireLine or Glasroc boards screw-fixed each side of light gauge metal framework.

The system is not suitable for use in areas subjected to continuous or intermittent damp or humid conditions.

Performance:

  • Strength and robustness: Satisfies BS 5234 requirements up to Severe Duty.
  • Fire resistance: Up to 240 minutes.
  • Sound insulation: Up to Rw 59 dB.

It can be specified with Gyproc Drywall Primer and Sealer.

General information
Specification data
Product Reference

FireWall

System

A20652

A20656

G106I019

G106I018

Head condition

Gypframe 72 C 50 Standard floor and ceiling channels, fixed to ___

Insert e.g. 'underside of ceiling joists'.

Gypframe 72 DC 60 Deep Flange floor and ceiling channels, fixed to ___

Insert e.g. 'underside of ceiling joists'.

Gypframe 148 C 50 Standard floor and ceiling channels, fixed to ___

Insert e.g. 'underside of ceiling joists'.

Gypframe 148 DC 60 Deep Flange floor and ceiling channels, fixed to ___

Insert e.g. 'underside of ceiling joists'.

Gypframe 94 EDC 70 Extra deep flange floor and ceiling channels, fixed to ___

Insert e.g. 'underside of ceiling joists'.

Finishing

Taped seamless finish

Skim coat plaster finish

To receive ceramic tiles

Accessories

None

Rigid beads/ stops

Other requirements

None

Access panels

Product Options

System:

– A206252:

  • Studs: Gypframe 70 S 50 'C' studs at 600 mm centres.
  • Lining: 3 x 15 mm FireLine to each side.
  • Wall thickness: 165 mm.
  • Maximum wall height: 4000 mm. (to BS EN 1364-1) 4900mm (to BS 476:Part 22).
  • Fire resistance: 180 minutes.
  • Sound insulation, Rw: 46 dB.

– A206256:

  • Studs: Gypframe 146 S 60 'C' studs at 600 mm centres.
  • Lining: 3 x 15 mm FireLine to each side.
  • Wall thickness: 240 mm.
  • Maximum wall height: 4000 mm. (to BS EN 1364-1) 7600mm (to BS 476:Part 22).
  • Fire resistance: 180 minutes.
  • Sound insulation, Rw: 50 dB.

– G106I019:

  • Studs: Gypframe 90 I 90 'I' studs at 600 mm centres.
  • Insulation: 90 mm of 100 kg/m³ stone mineral wool (40 mm plus 50 mm batts) in the cavity.
  • Lining: 2 x 15 mm FireCase s to each side.
  • Wall thickness: 155 mm.
  • Maximum wall height: 6900 mm.
  • Fire resistance: 180 minutes.
  • Sound insulation, Rw: 56 dB.

– G106I018:

  • Studs: Gypframe 90 I 90 'I' studs at 600 mm centres.
  • Insulation: 90 mm of 100 kg/m³ stone mineral wool (40 mm plus 50 mm batts) in the cavity.
  • Lining: 2 x 15 mm FireCase s and 1 x 6 mm MultiBoard to each side.
  • Wall thickness: 170 mm.
  • Maximum wall height: 6900 mm.
  • Fire resistance: 240 minutes.
  • Sound insulation, Rw: 59 dB.

Deflection allowance:

Consult British Gypsum technical literature for recommendations.