Verified by manufacturer 6 months ago
Lightweight, flexible fire wrap, with 60 minutes performance as a component within a FIREFLY™ fire barrier system.
FIREFLY Penowrap is a lightweight, flexible fire wrap, used as a component within our fire barrier systems. Penowrap provides 60 minutes Integrity and 60 minutes Insulation when used to wrap exposed sections of timber and steel. Tested to BS 476 Parts 20 & 22
USE AREAS
FIREFLY Penowrap is used as a component with other FIREFLY flexible fire barrier systems, suitable for wrapping timber and steel structure/substrate up to 300mm below the barrier for additional fire protection.
APPLICATION
Wrap to cover exposed timber and steel at the head of an installation, up to 300mm depth when used within a FIREFLY barriers system
PROPERTIES
Description: Non-toxic / flexible / durable. Easy to shape and cut
Coating: White / Silver foil
SPECIFICATIONS
Exceeds 60 minutes Integrity and 60 minutes Insulation when tested to BS476 Parts 20 & 22 in conjunction with a FIREFLY barrier system
CLASSIFICATIONS
Tested to BS476 parts 6 and 7 – Pass (propagation and surface spread of flame)
DIMENSIONS AND PACKAGING
Thickness: 130cm
Width: 30cm
Roll Area: 10 linear metres
Weight: 2.02 kg/m2
CONSTRUCTION
Manufactured using a layer of nonwoven silica with aluminium foil to the outward face.
KEY BENEFITS
Color | White Silver |
Finish | Reflective |
Material | Silica |
Shape | Rectangle |
Length | 10000 mm |
Width | 300 mm |
Height | 12 mm |
Warranty description | Ten year |
Uniclass | |
CAWS | K10/545 Cavity fire barriers within suspended ceilings K10/530 Cavity fire barriers within partitions/ wall linings P10/410 Flexible cavity barriers K10/15 Lining on timber K10/30 Metal stud K40/287 Cavity barriers K10/25 Ceiling lining on timber K10/35 Wall lining system (metal framing) K10/41 Wall lining system (metal furrings) K10/45 Wall lining system (adhesive) K10/57 Encasement on timber framing K10/55 Encasement system (metal framing) K10/50 Suspended ceiling system on metal framing |
Thickness | 12 mm. |
Fire performance | Fire resistance: 60/60 integrity/ insulation to BS 476-20 and BS 476-22. |
Contains Red List materials | No |
Country of material origin | China |
Country of product manufacture | China |
FIREFLY Apollo Horizontal 30:30 Fire Barrier
FIREFLY Athena 60:60 Fire Barrier
FIREFLY Collaroll Fire Barrier
FIREFLY Membrane NB A2 Class Barrier
FIREFLY Membrane WP A2 Class Barrier
FIREFLY Phoenix Horizontal Smoke & Flame Barrier
FIREFLY Phoenix Smoke & Flame Barrier - Smoke & flame barrier
FIREFLY Timber Wrap Fire Barrier
FIREFLY Titan Lite 120:60 Fire Barrier
FIREFLY Titan Lite 90:60 Horizontal Fire Barrier