BBA Agrément Certificate
Certificate type
QA Certificate
Certificate type
Twin stud, insulated partition system with high acoustic performance.
Twin stud, insulated partition system with high acoustic performance, based on Fermacell Gypsum-Fibreboard linings.
Uniclass 2015 | |
CAWS | K10/125 Metal stud partition system K10/30 Metal stud |
Product Reference | Fermacell 1S32 Insulated Partition |
Studs | Twin 50 mmTwin 75 mm |
Linings | - |
Type | One layer 12.5 mm Fermacell and one layer of 10 mm FermacellN.B When using Tapered Edge Boards, first layer must be a Square Edge Board, for double layer systems. Two layers 12.5 mm FermacellN.B When using Tapered Edge Boards, first layer must be a Square Edge Board, for double layer systems. |
Lining fixings | 30 mm Fermacell screws at 400 mm centres and 40 mm Fermacell screws at 250 mm centresBoth layers fixed to studs. 30 mm Fermacell screws at 250 mm centresFirst layer fixed to studs, outer layer fixed board to board. |
Insulation | 50 mm60 mm |
Finishing | - |
Type | Not requiredFermacell Fine Surface Treatment (FST) |
Joint treatment | Fermacell Jointstik 1 mm glued jointSquare edged boards. Fermacell Joint Filler 5–7 mm filled jointFor site cut boards. Fermacell Joint Reinforcement Tape and Fermacell Joint FillerTaper edge boards. |
Standard product features | Fire resistance: 90 minutes. Recycled content: Best Fermacell gypsum fibreboard contains 100% recycled content. All by-products recyclable. Other requirements: Fire stopping around service penetrations. Frame out openings with the same number of layers of board as per above specification. Sockets backed using baffle boxes, intumescent putty pads or suitable rock mineral wool, sufficient to maintain the fire/acoustic performance. Movement joints are required at maximum 8 linear metre intervals. Refer to manufacturer's literature. Vapour barrier as required for high humidity areas. For tiled areas reduce studs to 400 mm centres as required. Tile adhesive to be suitable for gypsum based substrate. Provide door reinforcement as required to suit door weights and opening size. Ensure no vertical joints at door jambs. Offset all board joints by minimum 200 mm. |
Product Options | Metal studs:
Insulation (minimum density):
Partition performance (based on stud type and insulation density/ thickness): - Twin 50 mm studs, 10 mm minimum air-gap, 10 + 12.5 mm Fermacell to each side:
- Twin 75 mm studs, 10 mm minimum air-gap, 10 + 12.5 mm Fermacell to each side:
|
Recycled content | Best Fermacell gypsum fibreboard contains 100% recycled content. All by-products recyclable |
Fermacell 1H11 Timber Stud Partition
Fermacell 1H13 Timber Stud Partition
Fermacell 1H21 H20 Timber Stud Partition
Fermacell 1H21 Timber Stud Partition
Fermacell 1H22 Timber Stud Partition
Fermacell 1H22-RB Timber Stud Partition
Fermacell 1H23 Timber Stud Partition
Fermacell 1H29 Timber Stud Partition
Fermacell 1H31 Timber Stud Partition
Fermacell 1H31-RB Timber Stud Partition