Fire-Spec is a range of ex-steel mould finish high performance units, available in 60, 90 and 120 minutes, dependent upon the section width. Other concrete sections can be made with a fire resistance equal to or greater than our standard range and our technical team with their special knowledge of concrete can advise you on which sections would achieve a specific fire resistance and strength rating and offer a design solution should this not be detailed in our load span tables.

Fair Faced Fire-Spec range:

Fair Faced Fire-Spec lintels are also available in a class C fair faced finish and again with a 60, 90 and 120 minute fire rating.

Standards:

  • Design complies with BS 8110 table 4.3, section 2.
  • Manufactured in accordance with BS EN 845-2: 2003.
  • Materials comply with BS EN 206 and BS 8500. The pre-stressing wire complies with BS 5896.
  • All fire rated lintels produced by Naylor Lintels comply with BS 8110 table 4.3, section 2.

General information
Finish

Colour

Insert requirements.

Faced

Color

Light grey

Features

Can be cut to length on site

Material

Concrete

Shape

Rectangle

Size

140 x 290 x 900 mm

Uniclass 2015
Pr_20_85_48_67 Prestressed concrete lintelsPrimary
CAWS

F30/745 Prestressed concrete lintels

Specification data - Prestressed concrete lintels
Product Reference

Fair-faced Fire-Spec Lintels

With a smooth, consistent colour finish.

Fire-Spec Lintels

As standard.

Type

Fire R3

Units suitable for 140 mm wide walls.

Fire R5

Units suitable for 140 mm wide walls.

Fire R8

Units suitable for 140 mm wide walls.

Fire R11

Units suitable for 140 mm wide walls.

Fire R2

Units suitable for 190 mm wide walls.

Fire R190

Units suitable for 190 mm wide walls.

Fire R13

Units suitable for 190 mm wide walls.

Fire R7

Units suitable for 215 mm wide walls.

Fire S8

Units suitable for 215 mm wide walls.

Fire R14

Units suitable for 215 mm wide walls.

As drawing

As schedule

Length

Insert requirements, or 'As drawing/ schedule'.

Fire resistance

60 minutes

90 minutes

120 minutes

Finish

Colour

Insert requirements.

Faced

Product Options

Length:

All lintels are available in lengths up to 3600 mm.

Fire resistance:

Fire resistance:

Digital objects
PlatformCompatibleVersionCertified to
IFC
IFC2X3 4 1.3
Revit
Revit 2016 5 2.0
Download now from NBS National BIM Library