Facade S

Application

Suitable for exteriors on walls or ceilings.

Please note that due to the fact that wood is a natural product, each veneer may have colour and structure differences. Singularities such as knots and resin inclusions are not considered as defects. There are differences in light fastness performances depending on the wood species and the source of the wood - consult manufacturer for further details.

Description

A laminated wood board for exteriors which requires minimal maintenance. The panels combine the virtues of wood with technical requirements to ensure optimum performance on exteriors over time.

It can be installed as a ventilated facade by way of louvres or overlapping slats, on false ceilings, as soffits and on curved walls. Available in nine shades that are obtained through ayous or okume veneer.

Construction:

  • Polyvinylidene fluoride (PVDF) anti-graffiti overlay.
  • Everlook®.
  • Natural timber veneer.
  • High pressure laminate (HPL) core.
  • Natural timber veneer.
  • Balancing film.

Features and benefits:

  • No maintenance required - the surface composition protects against adverse weather conditions, eliminating the need for any maintenance or treatment.
  • Reaction to fire - good results for organic materials in accordance with European and US regulations BS EN 13501 and US ASTM/NFPA for reaction to fire, making it globally approved.
  • Ventilated facade - offers permeability, water protection, thermal insulation, solar and acoustic protection.
  • Manufactured in accordance with BS EN 438.

Applications:

Suitable for exteriors on walls or ceilings.

Please note that due to the fact that wood is a natural product, each veneer may have colour and structure differences. Singularities such as knots and resin inclusions are not considered as defects. There are differences in light fastness performances depending on the wood species and the source of the wood - consult manufacturer for further details.

General information

Uniclass 2015

Pr_25_71_97_22 Decorative laminated plastics sheet veneered panelsPrimary

CAWS

H20/150 Sheet cladding

H20/155 Sheet cladding

Specification data - Decorative laminated plastics sheet veneered panels

Product Reference

Facade S

Board size

2440 x 1220 mm

Standard.

Special order

Insert requirement from 'Options' below.

Thickness

6 mm

Not available with louvres or overlapping ventilated facades, for very special cases only.

8 mm

Not available with louvres.

12 mm

Not available with overlapping ventilated facades.

16 mm

Not available with overlapping ventilated facades.

20 mm

Not available with overlapping ventilated facades.

Species/ Colour

Ambar

Antra

Bronze

Copper

Gold

Onix

Quartz

Rubi

Silver

Installation

Curves

Dropped ceiling

Louvres

Ventilated facade

Accessories

Insert requirements, consult manufacturer's literature for information.

Standard product features

Technical characteristics:

  • Dimensional stability (to BS EN 438-2 section 17): Longitudinal: 0.3% (maximum); transversal: 0.6% (maximum).
  • Resistance to impact (to BS EN 438-2 section 21): ≥1800 mm.
  • Tensile strength (to BS EN ISO 527-2): ≥60 MPa.
  • Graffiti resistance (to ASTM D 6578): Permanent blue marker: 4; red spray paint: 4; black wax crayon: 1; water based black marker: 2.
  • Resistance to UV light (to BS EN 438-2 section 28): ≥3 grey scale rating.
  • Resistance to UV light (to BS EN 20105 - A02): ≥4 rating.
  • Resistance to artificial weathering (including light fastness, to BS EN 438-2 section 29): ≥3 grey scale rating.
  • Resistance to artificial weathering (including light fastness, to BS EN 20105 - A02): ≥4 rating.
  • Water vapour permeability (to BS EN 438-7 section 4.4): Wet cup method: 110 μ; dry cup method: 250 μ.
  • Resistance to fixings (to BS EN 438-7 section 4.5): 6 mm thickness: >2000 N; 8 mm thickness: >3000 N; ≥10 mm thickness: >4000 N.
  • Flexural strength (to BS EN ISO 178): ≥80 MPa.
  • Flexural elastic modulus (to BS EN ISO 178): ≥9000 MPa.
  • Thermal conductivity (to BS EN 12664): 0.266 W/m·K.
  • Resistance to climatic shock (to BS EN 438-2 part 19): Appearance: ≥4 rating; flexural strength: ≥0.95 Ds rating; flexural modulus: ≥0.95 Dm rating.
  • Resistance to wet conditions (to BS EN 438-2 section 15): Moisture absorbed: ≤5%; appearance: ≥4 rating.
  • Density (to BS EN ISO 1183): ≥1.35 g/cm³.
  • Reaction to fire (to BS EN 13501-1): C-s2,d0.

Product Options

Installation:

- Curves:

The flexibility of the wood fibres allows the facade panels to adapt to certain radii of curvature, whether concave or convex. Two different solutions are available; either standard panels if radii above 3 m are required; or pre-bent panels if smaller radii are required.

- Dropped ceiling:

The facade boards can be installed on false ceilings by means of exposed or concealed fixing systems. In the case of false ceilings, a minimum perimeter space of 20 mm must be left to enable ventilation through the chamber.

- Louvres:

Slats are installed at 0º, 30º or 60º, both horizontally and vertically. The slats are available in three different widths: 86 mm, 94 mm and 114 mm, with a maximum slat length of 2440 mm.

- Ventilated facade:

Overlapping slats can be supplied in width of 190 mm and 290 mm, both with a maximum length of 2440 mm. This concealed fixing system is only valid for thicknesses of 8 mm.

Third party certifications

  • Certificate: 08/4573

Similar products from Prodema UK & Ireland Ltd

Facade F

Wet Internal F

Wet Internal F