Fire rated horizontal cladding wall system.
All Euroclad products are manufactured under a Quality Management System accredited to ISO 9001 and an Environmental Management System accredited to ISO 14001. Elite systems are completely non-combustible and recyclable, with the option of a 12 or 25 year Guarantee; the system must be installed by a Euroclad Elite Systems recommended installer.
Elite System 56fr is fast and economical horizontal clad walling for light industry, retail, dry sports and leisure buildings giving maximum 4 hours fire resistance.
Elite System 56 non-fire rated version is also available.
Product Reference | Elite System 56fr |
External sheet | - |
Type | MW5CS profile. |
Finish | Corus Colorcoat HPS200®Corus Colorcoat Prisma® |
Colour | ___ |
Vapour control membrane | Monarflex VBProcheck 500Not required |
Accessories | Flashings, finish and colour matching external sheetNot required |
Standard product features | External sheet: Type: Euroclad MW5CS, 0.7 mm steel. Cover width: 1000 mm. External Sheet Colours: From Corus Standard Range, Repertoir and through consultation with Euroclad. Liner panel: Euroclad 19/1000 0.4 mm steel, standard factory finish. Spacers (0.30 U-value): Eurobar Mast 135 mm high. Breather membrane: Euroclad does not recommend a breather membrane in Elite systems. Vapour control membrane: Euroclad recommend the use of A Proctor Procheck 500 or Monarflex VB with a minimum vapour resistance of 500 MNs/g together with Probond RG Tape or Monobond sealant with vapour resistivity equal to the vapour control layer. Fire rating (maximum): 4 hours fire resistance. Sheeting rails:
System U-value:
Acoustic performance (140 mm Euroclad Elite Flexislab/ 0.7 mm steel): SRi = 41dB - contact Euroclad for details |
Product Options | External sheets: Coating:
Accessories: Flashings, rainwater goods, fabricated details and trims can also be provided by Euroclad who can also recommend suppliers of compatible rooflights and fall arrest systems. |