NBS Source
I'm a manufacturer

Application

  • Suitable for refurbishment or new build.
  • Can be used for many types of roof, including flat, pitched and barrel vaulted.
  • May also be used on waveform roofs or those with a distinctive design and shape.

Description

Flame retardant torch-on waterproofing system for flat roofs.


Features and benefits:

  • Secure, durable covering for flat roofs.
  • Manufactured with an untearable, spun bond polyester carrier, coated in polyalphaolefin (PAO) modified bitumen, combining the strength of APP with the flexibility of SBS products.
  • Resistant to UV light.
  • Life expectancy in excess of 30 years.
  • Best suited to projects where a high performance product is a key requirement.


Also available as an torch-on warm roof system or as a cold roof system (all specified separately).

An anti-root version, System 17000 AR can also be specified.

General information

Color

Black

Guidance for specification option:

Charcoal.

Finish

Mineral

Material

Bitumen

Guidance for specification option:

Spun bond polyester carrier, coated in polyalphaolefin (PAO) modified bitumen.

Shape

Rectangle

Size

Guidance for specification option:

1 m-wide roll.

Length

8000 mm

Width

1000 mm

Height

5.0 mm

Warranty description

30 year

Guidance for specification option:

Consult manufacturer for details.

Uniclass

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

J41/10 Reinforced bitumen membrane warm deck roof covering

Product range

Flat Roofing Systems / Bitumen Felt

Specification data - Reinforced bitumen membrane warm roof covering systems

Preparation

-

Horizontal work

Bailey self-adhesive membrane primer.

Guidance for specification option:

22 L cannister.

Skirtings and vertical work

Bailey self-adhesive membrane primer.

Guidance for specification option:

22 L cannister.

Air and vapour control layer

-

Type

Bailey Alpha-Bar aluminium cored-bitumen self-adhesive vapour barrier.

Attachment

Self-adhered.

Insulation

-

Type

Bailey Sure-Therm PIR glass tissue-faced flat board insulation, __ mm.

Guidance for specification option:

Insert requirements.

Bailey Sure-Therm PIR glass tissue-faced tapered insulation scheme, __ falls.

Guidance for specification option:

Insert requirements; .standard falls: 1:80, 1:60, 1:40.

Non-standard falls available.

Bailey Sure-Therm non-combustible mineral wool flat board, __ mm.

Guidance for specification option:

Insert requirements.

Bailey Sure-Therm non-combustible mineral wool tapered insulation scheme, __ falls..

Guidance for specification option:

Insert requirements; .standard falls: 1:80, 1:60, 1:40.

Non-standard falls available.

Fixing

Sure-Bond PU insulation adhesive.

Waterproof covering

-

Intermediate layer

-

Type

Bailey Universal 3 mm self-adhesive underlay.

Attachment

Self-adhered.

Top layer

-

Type

Bailey System 17000 FR self-adhesive mineral capsheet.

Attachment

Self-adhered.

Detail work

-

Flashings

Bailey Universal 3 mm self-adhesive underlay and System 17000 FR self-adhesive mineral capsheet

Skirtings and upstands

Bailey Universal 3 mm self-adhesive underlay and System 17000 FR self-adhesive mineral capsheet

Welted drips

System 17000 FR self-adhesive mineral capsheet.

Cover strips

System 17000 FR self-adhesive mineral capsheet.

Surface protection

Bailey 300 g/m² geotextile protection fleece.

System accessories

Not required.

Outlets - specified below.

Guidance for specification option:

See 'Outlets' for details.

Bailey Sure-flow stainless steel leaf guard - F-631-L.

Bailey Sure-flow stainless steel parapet leaf guard - F-632-LP.

Bailey Sure-flow stainless steel cylindrical leaf guard - F-633-LC.

Bailey Sure-flow stainless steel balcony leaf guard - F-634-LB.

Bailey Flow-therm standard retaining unit - 25–105 mm - F-652-25/105.

Bailey Flow-therm parapet leaf guard - 110 mm - F-663-110.

Bailey Flow-therm parapet leaf guard - 75 mm - F-663-75.

Bailey Flow-therm parapet connecting pipe - 110 mm - F-664-110.

Bailey Flow-therm parapet connecting pipe - 75 mm - F-664-75.

Execution

-

Manufacturer guidance

Bailey System 17000 FR should only be installed by approved or registered contractors, experienced and trained in the installation of torch-on products.

Outlets

Bailey Sure-flow stainless steel outlet - 40 mm (felt flange) - F-630–40.

Bailey Sure-flow stainless steel outlet - 50 mm (felt flange) - F-630–50.

Bailey Sure-flow stainless steel outlet - 62 mm (felt flange) - F-630–62.

Bailey Sure-flow stainless steel outlet - 70 mm (felt flange) - F-630–70.

Bailey Sure-flow stainless steel outlet - 75 mm (felt flange) - F-630–75.

Show more

Sustainability data

Contains Red List materials

No

Similar products from Bailey - Total Building Envelope

Bailey Classic Plus FR System (Warm Roof)

Bailey Classic Plus FR System (Warm Roof)

Bailey System 17000 AR (Warm Roof)

Bailey System 17000 AR (Warm Roof)

Bailey System 17000 FR (Warm Roof)

Bailey System 17000 FR (Warm Roof)

Bailey System 5000 FR Adhered (Warm Roof)

Bailey System 5000 FR Adhered (Warm Roof)

Bailey System 5000 FR Mechanically Fixed (Warm Roof)

Bailey System 5000 FR Mechanically Fixed (Warm Roof)