Specialist sanded-finish, anti-root waterproofing system.
Suitable for use on podium decks and green roof applications without the need for a root barrier.
Specialist sanded-finish, anti-root waterproofing system for green roof applications.
Features and benefits:
Color | Black Guidance for specification option: Charcoal. |
Finish | Sanded |
Material | Bitumen |
Shape | Rectangle |
Size | Guidance for specification option: 1 m-wide roll. |
Length | 10000 mm |
Width | 1000 mm |
Height | 4.5 mm |
Warranty description | 30 year |
Uniclass | |
CAWS | J41/110 Built-up reinforced bitumen membrane warm deck roof covering J41/10 Reinforced bitumen membrane warm deck roof covering |
Product range |
Preparation | |
Horizontal work | Bailey self-adhesive membrane primer.Guidance for specification option: 22 L cannister. Bailey AMC high penetration bitumen primer.Guidance for specification option: 25 L drum. |
Skirtings and vertical work | Bailey self-adhesive membrane primer.Guidance for specification option: 22 L cannister. Bailey AMC high penetration bitumen primer.Guidance for specification option: 25 L drum. |
Air and vapour control layer | |
Type | Bailey Alpha-Bar aluminium cored-bitumen self-adhesive vapour barrier. |
Attachment | Self-adhered. |
Insulation | |
Type | Bailey Sure-Therm PIR bitumen-faced flat board insulation, __ mm.Guidance for specification option: Insert requirements. Bailey Sure-Therm PIR bitumen-faced tapered insulation scheme, __ falls.Guidance for specification option: Insert requirements; .standard falls: 1:80, 1:60, 1:40. Non-standard falls available. Bailey Sure-Therm PIR glass tissue-faced flat board insulation, __ mm.Guidance for specification option: Insert requirements. Bailey Sure-Therm PIR glass tissue-faced tapered insulation scheme, __ falls.Guidance for specification option: Insert requirements; .standard falls: 1:80, 1:60, 1:40. Non-standard falls available. Bailey Sure-Therm non-combustible mineral wool flat board, __ mm.Guidance for specification option: Insert requirements. Bailey Sure-Therm non-combustible mineral wool tapered insulation scheme, __ falls..Guidance for specification option: Insert requirements; .standard falls: 1:80, 1:60, 1:40. Non-standard falls available. |
Fixing | Bonding with hot bitumen.Sure-Bond PU insulation adhesive.Bailey Sure-Fix insulation tube washers, Bailey Sure-Fix steel deck fixings.Guidance for specification option: To required length. Bailey Sure-Fix insulation tube washers, Bailey Sure-Fix timber deck fixings.Guidance for specification option: To required length. Bailey Sure-Fix insulation tube washers, Bailey Sure-Fix concrete deck fixings.Guidance for specification option: To required length. |
Waterproof covering | |
First layer | |
Type | Bailey Alpha-Vent perforated venting layer. |
Attachment | Loose-laid. |
Intermediate layer | |
Type | Bailey System 17000 3 mm torch-on underlay. |
Attachment | Torch-on. |
Top layer | |
Type | Bailey System 17000 AR anti-root torch-on mineral capsheet. |
Attachment | Torch-on. |
Detail work | |
Flashings | Bailey System 17000 3 mm underlay and FR torch-on mineral capsheet. |
Skirtings and upstands | Bailey System 17000 3 mm underlay and FR torch-on mineral capsheet. |
Welted drips | Bailey System 17000 FR torch-on mineral capsheet. |
Cover strips | Bailey System 17000 Ar anti-root torch-on mineral capsheet. |
Surface protection | Bailey 300 g/m² geotextile protection fleece. |
System accessories | Manufacturer guidanceOutlet options specified below. |
Outlets | Bailey Sure-flow stainless steel outlet - 40 mm (felt flange) - F-630–40. Bailey Sure-flow stainless steel outlet - 50 mm (felt flange) - F-630–50. Bailey Sure-flow stainless steel outlet - 62 mm (felt flange) - F-630–62. Bailey Sure-flow stainless steel outlet - 70 mm (felt flange) - F-630–70. Bailey Sure-flow stainless steel outlet - 75 mm (felt flange) - F-630–75. |
Contains Red List materials | No |