Automatic smoke vent for flat roof skylight.

Jump to:
+44 (0)1922 500 145 Website

Application

The Automatic Smoke Vent for Flat Roof Skylight is designed for easy installation on flat roofs of all modern building types.

Description

Automatic Smoke Vent for Flat Roof Skylight providing natural smoke and heat exhaust, as well as comfort ventilation. Designed, fully tested and certified in accordance with EN 12101-2. Mardome Smoke Vent Dome Rooflights meet standards for safety, security, non-fragility and fire safety and we offer the full guarantee of an established, accredited UK manufacturer.


It offers a contemporary, reliable and robust smoke system which maximizes natural light in both new and refurbished buildings. Options include a control panel, with accessories such as smoke detector, fire switch and fireman’s priority switch. The Actuator can be offset Left to use as an Access Hatch to roof.


To suit existing upstand rooflight/ AOV sizes are external kerb sizes and must be fitted onto a 75 mm wide kerb. For example, the 1200 x 1200 mm unit has an external kerb size of 1200 x 1200 mm and and an internal size of 1050 x 1050 mm.

The daylight size will be 150 mm smaller than the Rooflight size (i.e. the 1200 x 1200mm rooflight would provide a daylight size of 1050 x 1050 mm).


Features and benefits:

  • Smoke and heat exhaust ventilation system for all Commercial and Residential applications.
  • Factory assembled and factory tested, certified to CE EN 12101-2.
  • Automated smoke extraction in the event of a fire.
  • Day-to-day controllable ventilation.
  • The Actuator can be offset left or right to use as an access hatch to roof.
  • Complies with the latest Building Regulations on fire safety.
  • Can be integrated into any building management system.
  • Linked to a central control panel.
  • Complete with a battery backup system in case of mains failure.
  • Control panel can be triggered from either manual override switches local to the ventilator and the ground floor, by dedicated smoke detectors, or by interfacing with a third-party smoke detection/fire alarm system.
  • High-quality AOV system.
  • Variety of sizes for all flat roofing types.
  • Thermal performance – triple skin for optimal thermal performance & resistance to condensation.
  • Non-fragile – Class B non-fragility to ACR[M]001.
  • Secure – highly secure as individual fixings are concealed inside security caps.
  • Fire rating – achieves Class B-s1, d0 to BS EN 13501: Part 1, and deemed BROOF(t4) to BS EN 13501: Part 5 by Building Regulations.
  • Available in double, triple, clear, textured and opal skin polycarbonate glazing.
  • Excellent waterproofing properties - weathered to the full height of the upstand, water penetration is virtually impossible.

General information

Color

White

Material

Polycarbonate

PVC-U

Guidance for specification option:

Unplasticized polyvinyl chloride (PVC-U).

Shape

Square

Rectangle

Length

1050 mm

1200 mm

1350 mm

1500 mm

Width

1050 mm

1200 mm

1350 mm

1500 mm

Warranty description

Ten year

Uniclass

Pr_70_65_04_56 Natural smoke and heat exhaust ventilatorsPrimary

CAWS

L10/490 Roof ventilators

Specification data - Natural smoke and heat exhaust ventilators

Standard

To BS EN ISO 12567-2.

Mounting

Roof-mounted.

Arrangement

Double skin.

Materials

-

Integral upstands

-

Material

PVC-U.

Colour

Clear.

Guidance for specification option:

High visibility, and maximum light transmission.

Opal.

Guidance for specification option:

Diffused light and solar control. Prevents solar glare and reduces solar heat gain.

Textured.

Guidance for specification option:

Combines privacy with high levels of light transmission.

Accessories

Not required.

Control panel system.

Guidance for specification option:

Available in 5 A and 8 A options and comes with a built-in comfort switch at the front.

Fire switch.

Guidance for specification option:

Will open the smoke vent and activate the alarm.

Fireman's switch.

Guidance for specification option:

Will open/ close the smoke vent without influencing the alarm.

Smoke detector.

Guidance for specification option:

Allows early fire detection with a visual release display.

Shape

Dome.

Pyramid.

Upstand

100 mm, vertical direct fix.

Guidance for specification option:

For mounting to 200 mm builder's upstand.

300 mm, sloped.

Guidance for specification option:

For mounting at roof surface level.

Light transmission

Clear: 85%; textured: 78%; opal: 35%.

ThermalEfficiency

2.7 W/m²K.

Dimensions

1050 x 1050 mm.

Guidance for specification option:

Daylight free area: 900 x 900 mm; roof opening area: 1.1 m².

1050 x 1200 mm.

Guidance for specification option:

Daylight free area: 900 x 1050 mm; roof opening area: 1.26 m².

1050 x 1350 mm.

Guidance for specification option:

Daylight free area: 900 x 1200 mm; roof opening area: 1.42 m².

1050 x 1500 mm.

Guidance for specification option:

Daylight free area: 900 x 1350 mm; roof opening area: 1.58 m².

1200 x 1200 mm.

Guidance for specification option:

Daylight free area: 1050 x 1050 mm; roof opening area: 1.44 m².

Show more

Third-party certification

BBA Agrément Certificate.

Non-fragility rating

Class B.

Actuator

Central.

Offset left.

Guidance for specification option:

Not available with 1050 x 1050 mm.

Sustainability data

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Polycarbonate

PVC-U

Guidance for specification option:

Unplasticized polyvinyl chloride (PVC-U).

Literature

Smoke Vent System Rooflight - Mardome AOV Automatic Smoke Ventilation

Smoke Vent System Rooflight - Mardome AOV Automatic Smoke Ventilation

Brett Martin Warranty

Brett Martin Warranty

Similar products from Trade Access Panels

2-in-1 Aluminium Smoke Vent System | AOV Roof Access Hatch  - Roof Hatch, AOV

2-in-1 Aluminium Smoke Vent System | AOV Roof Access Hatch - Roof Hatch, AOV

AOV Smoke Vent System Rooflight | Mardome AOV | Automatic Smoke Ventilation  - Roof Hatch, AOV

AOV Smoke Vent System Rooflight | Mardome AOV | Automatic Smoke Ventilation - Roof Hatch, AOV