Insulated roof and wall underlay membrane that is airtight and ventilated. Aluthermo RoofReflex® can be used in conjunction with standard insulation products to enhance the achieved U-value of any installation, through an integrated insulation layer that is laminated to a high emissivity surface.

Manufactured using hydrophobic and self-extinguishing polyester fibre, created from recycled material. Aluthermo RoofReflex® has integrated sealing tapes to quickly and easily maintain the airtight seal at all joints. Suitable for use below tiles and cladding.

Features:

  • Low emissivity external face.
  • Improved acoustic values.
  • Reduces thermal bridge losses.
  • Fully airtight when installed with the supplied integral tapes.
  • Reduces overheating in summer by providing a cooling effect and lowering air-conditioning costs.
  • Adds up to 1.47 m²K/W in thermal resistance (R-value).
  • Hybrid roof and wall membrane combined with an insulation layer.
  • Lower installation costs than PIR systems.
  • EPC-approved and LABC-approved.
  • CE-marked to EN 13859-1 and -2.
  • Ten-year warranty.

General information
Features

Low emissivity external face

Improved acoustic values

Reduces thermal bridge losses

Fully airtight when installed with the supplied integral tapes

Reduces overheating in summer by providing a cooling effect and lowering air-conditioning costs

Adds up to 1.47 m²K/W in thermal resistance (R-value)

Hybrid roof and wall membrane combined with an insulation layer

Lower installation costs than PIR systems

EPC-approved and LABC-approved

CE-marked to EN 13859-1 and -2

Ten-year warranty

Uniclass 2015 Vapour permeable sheets (Pr_25_57_10_94)
Specification data
Product Reference

Aluthermo RoofReflex®

Tape

Novia Breather Membrane Lap Tape

Standard product features

Roll size:

1.4 x 10 m.

Surface area per roll:

14 m².

Weight:

730 g/m².

Thickness of the polyester fibre:

37 mm.

Technical characteristics:

  • Operating temperature range: -40°C to +80°C.
  • Fire resistance classification: E.
  • Thermal core resistance (R-value): 1 m²K/W.
  • Thermal conductivity (K-value to EN 12667): 0.0366 W/m·K.
  • Thermal resistance together with one unventilated air gap, wall (R-value): 1.47 m²K/W.
  • Resistance to water penetration (to EN 1928): W1.
  • Water vapour transmission: 380 g/m².d.
  • Tensile property, longitudinal: 220–360 N/50mm.
  • Tensile property, traversal (to EN 12311-1): 150–275 N/50mm.
  • Resistance to tearing, longitudinal: 120–230 N.
  • Resistance to tearing, traversal (to EN 12310-1): 175–280 N.
  • Standard deviation (Sd) value (to EN 12572:2003): <0.061 m (±0.01).
  • Emissivity: 0.18.