BSI Kitemark
Certificate type
QA Certificate
Certificate type
Aluminium web-perforated roof decking.
Suitable for all roofing types including:
Aluminium web-perforated roof decking to provide acoustic absorption, acoustic reduction (rating A–D) and structural support.
Fully perforated decks also available, consult the manufacturer for details.
Acoustic RoofDek trapezoidal profiles D46 to D100:
D46, D60 and D100 use perforating pattern 4546, 4.5 mm holes at 6.3 mm triangular centres. Pattern open area: 46%.
Acoustic RoofDek trapezoidal profiles D137 and D159:
D137 and D159 use perforating pattern 3327, 3.3 mm holes at 6 mm triangular centres. Pattern open area: 27%.
Features and benefits:
Applications:
Suitable for all roofing types including:
Material | 0.90 mm aluminium D46, D60 and D100. 1.20 mm aluminium D46, D60 D100 and D137. 1.50 mm aluminium D137 and D159. |
Finish | Mill Polyvinylidene difluoride (PvDF) Stucco - grade 3005 H27 |
Uniclass 2015 | |
CAWS | E60/140 Precast floor plate |
Product Reference | Aluminium Web-Perforated Structural RoofDek |
Profile | D46900 mm cover width. 225 mm pitch. Exposed area: 10.79%. Cover area: 13.09%. D60800 mm cover width. 200 mm pitch. Exposed area: 13.9%. Cover area: 19.6%. D100700 mm cover width. 233.3 mm pitch. Exposed area: 13.3%. Cover area: 21.1%. D137930 mm cover width. 310 mm pitch. Exposed area: 7%. Cover area: 11.5%. D159750 mm cover width. 250 mm pitch. Exposed area: 7.6%. Cover area: 14.2%. |
Material | 0.90 mm aluminiumD46, D60 and D100. 1.20 mm aluminiumD46, D60 D100 and D137. 1.50 mm aluminiumD137 and D159. |
Finish | MillPolyvinylidene difluoride (PvDF)Stucco - grade 3005 H27 |
Additional requirements | NoneFactory crimp curving, 0.40 m radiusOptionally available for D46. |
Standard product features | Material: Aluminium alloy to BS EN 485-1/2/3/4:1995. Coated grade 3004 H44. Mill and stucco - grade 3005 H27. Consult manufacturer for the availability of types of coating or finish which depends on profile and other factors. Depth of deck: The profile reference indicates the depth of the deck, e.g. D100 = 100 mm deep. Fire performance:
Technical characteristics: Varies depending on material and thickness, consult technical literature for weight, single and double span data, plus minimum self-curve and cantilever information. |
Product Options | Profile:
|
Colorcoat® LG
Colorcoat® pre-finished steel for the building envelope
Confidex Sustain® The world’s first cradle to cradle CarbonNeurtal® building envelope
Photovoltaic installation guidelines for industrial and commercial buildings
Acoustic performance of pre-finished steel cladding systems
Structural performance of built-up roof and wall cladding systems
Ensuring consistent appearance of pre-finished steel wall cladding
Refurbishment solutions for non-domestic solutions
The effect of gauge on pre-finished steel roof and wall cladding performance
Creating an air-tight building envelope