NBS Source
I'm a manufacturer
Compare variants

AluK SC156 Lift and Slide Thermally Broken Sliding Door System

Verified by manufacturer 2 months ago

Anodized.

AluK (GB) Ltd Variant:

Thermally broken aluminium lift and slide door.

Jump to:
+44 (0)1291 639739 Website

Application

Suitable for external applications on residential and commercial new build and refurbishment projects.

Description

Thermally broken aluminium lift and slide door.


Features and benefits:

  • Can be assembled in two, three and four panel configurations including fixed lights and sliding doors.
  • Aluminium profiles are extruded in accordance with BS EN 12020, and are manufactured from grade 6060/6063 T6 aluminium.
  • Compliant with ADL1/ ADL2 capable of achieving U-values of 1.5 W/m²K, dependent upon combined glass centre pane and window area weighted average offsets.
  • A variety of powder coated colours are available in accordance with BS 6496 and BS EN 12206-1:2004.
  • Powder coating is applied to a Qualicoat standard, utilizing an inline flash anodizing pre-treatment process, with the polyester powder coating applied within 30 minutes of the flash anodizing process to ensure suitable adhesion.
  • Doors can be dual coloured, textured or have an anodized finish.


General information

Color

Other

Guidance for specification option:

Insert RAL colour requirement or type 'Not applicable' for anodized.

Finish

Anodized

Guidance for specification option:

To a minimum 15 micrometres thickness.

Polyester powder coated

Guidance for specification option:

Polyester powder coated to a minimum 60 micrometres thickness.

Polyester powder coated to a minimum 60 micrometres thickness with marine environment guarantee.

Material

Aluminium

Glass

Shape

Rectangle

Width

1200 mm

Guidance for specification option:

Tested limits.

2700 mm

Guidance for specification option:

Hardware limits.

Manufacturer guidance

Recommended size limits.

Height

2200 mm

Guidance for specification option:

Tested limits.

3100 mm

Guidance for specification option:

Hardware limits.

Manufacturer guidance

Recommended size limits.

Uniclass

Pr_30_59_24_80 Sliding door and partition setsPrimary

CAWS

L20/520 Sliding doors

L20/60 Doors

Product range

Inline Sliding Doors

Specification data - Sliding door and partition sets

Arrangement

Bi-parting opening.

Door leaves

-

Finish and colour

Anodized.

Guidance for specification option:

To a minimum 15 micrometres thickness.

Operation

Manual.

Accessories

Not required.

K1459.

Guidance for specification option:

Reinforcement profile.

K2406.

Guidance for specification option:

Meeting stile.

K2416.

Guidance for specification option:

Locking post.

Execution

Installing hardware.

Product Reference

AluK SC156 Lift and Slide Thermally Broken Sliding Door System

Outer frame

800150.

Guidance for specification option:

Pultruded threshold.

K2400.

Guidance for specification option:

Outer frame.

K2410.

Guidance for specification option:

Single track threshold.

K2411.

Guidance for specification option:

Double track threshold.

Vent

K2404.

Guidance for specification option:

Standard leaf and Interlock.

K2413.

Guidance for specification option:

Slim frame and Interlock.

Coupler

Not required.

U02900.

Guidance for specification option:

Coupling bar.

Configuration

Duo rail - OX.

Guidance for specification option:

Two panels/ one sliding.

Duo rail - XX.

Guidance for specification option:

Two panels/ two sliding.

Duo rail - OXXO.

Guidance for specification option:

Four panels/ two sliding.

Mono rail - OX.

Guidance for specification option:

Two panels/ one sliding.

Mono rail - OXO.

Guidance for specification option:

Three panels/ one sliding.

Show more

Glazing

Glass panels.

Guidance for specification option:

28–50 mm glass look-a-like panels, insert requirements.


Glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing.

Glazing.

Guidance for specification option:

28–50 mm insulating glass units, insert requirements.


Insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door).

Infill panels.

Guidance for specification option:

8–50 mm insulated sandwich panels, insert requirements.


Insulated sandwich panels incorporating two sheets of a minimum 2-mm thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core.

Texture

Not required.

Guidance for specification option:

For anodized.

Ironmongery

7183XX.

Guidance for specification option:

Tokyo handle.

7184X6.

Guidance for specification option:

Amsterdam handle.

FrameDepth

156 mm.

Bead

Square.

Panel weight

400 kg.

Manufacturer guidance

Recommended weight limits (maximum).

Air permeability

Class 4 (600 Pa).

Watertightness

E1500 (1500 Pa).

Wind resistance

Class B4 (1600 Pa).

Size:

2700 x 3100 mm.

Guidance for specification option:

Two panels (w x h): hardware limits.

1200 x 2200 mm.

Guidance for specification option:

Two panels (w x h): tested limits.

As drawing.

Guidance for specification option:

Insert reference.

As schedule.

Guidance for specification option:

Insert reference.

Similar products from AluK (GB) Ltd

AluK BSC94 Inline Thermally Broken Sliding Door System

AluK BSC94 Inline Thermally Broken Sliding Door System

AluK BSC94 Lift and Slide Thermally Broken Sliding Door System

AluK BSC94 Lift and Slide Thermally Broken Sliding Door System

AluK BSF70 HI Thermally Broken Sliding Folding Door System

AluK BSF70 HI Thermally Broken Sliding Folding Door System

AluK F82 Thermally Broken Sliding Folding Door System

AluK F82 Thermally Broken Sliding Folding Door System

AluK Infinium Thermally Broken Sliding Door System

AluK Infinium Thermally Broken Sliding Door System